Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PERjp <br />NEC 14, 250.94 <br />NEMA 1 <br />200 AMP <br />copper to lights & outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4 _ <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;O� <br />EXHAUST FAN/LIGHT COMBINATION <br />® D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />17 <br />L T 1)OPT. <br />CEILING FAN <br />(9�) <br />(1) PHONE LINE, (1) DATA PORT <br />WP DISC. <br />GFI H.B. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />nr—n nnrnG, <br />RECEPT. <br />FOR ALARM <br />SYSTEM — <br />V CnIF I IVIC I Cf\ <br />LOCATION WITH <br />BUILDER <br />ENTRY <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />0 <br />CV <br />0 <br />CV <br />v <br />0 <br />m <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />_ � N (p W <br />N #J <br />00M O Oi <br />tei <br />LQ�i <br />Ot <br />N Q N <br />(a <br />4t 00 ILL <br />0 <br />y <br />�M� N <br />-,J <br />_. <br />LL-1a <br />N <br />a <br />0j M <br />>�'ii <br />W N <br />aa� <br />Z <br />< <br />6 o <br />cc�o <br />Wmo <br />m <br />W'to <br />o n t° <br />2 E c rn <br />IT <br />o a <br />Z <br />LLW <br />V N <br />N Q c> Z <br />J <br />Q O go <br />0 <br />Z <br />U J <br />4 U ❑�❑ <br />W <br />CD <br />M <br />Z N M CD <br />_ <br />z <br />J M <br />d N <br />N <br />M <br />z <br />QD LL <br />Cn Y <br />LLj <br />a <br />U <br />o a <br />v ' <br />LA <br />R[ <br />LLI <br />C E <br />ZS 02 <br />O <br />V <br />_ <br />pp <br />LIJ <br />off= <br />r E2 E <br />O 8 <br />l� ... <br />0 <br />• <br />_0 <br />a 0 <br />sm <br />oCIO <br />w <br />M <br />o <br />z <br />z¢ <br />� <br />a E <br />0 <br />zo <br />�0 <br />oLL <br />wz <br />Yo <br />¢� <br />Z® <br />oa <br />E <br />Iu <br />O <br />OU <br />� <br />CV rB <br />i <br />d ZO <br />o <br />az <br />(� <br />U) <br />C <br />U <br />0O <br />, <br />z F <br />ZN <br />J <br />m <br />Q W <br />rn <br />a 3 <br />3 <br />a ° <br />0.1 <br />z <br />50 <br />U <br />K0 <br />ao <br />oz <br />�k <br />=3 <br />GOOD <br />V <br />< <br />i¢ <br />> 0 <br />a <br />003 <br />�N <br />0 <br />= <br />> d' <br />d <br />@ <br />^L <br />W <br />c� <br />D <br />' <br />�= <br />T <br />c <br />Cfl <br />cc <br />J <br />N <br />O <br />^Q <br />CL <br />o <br />� <br />(� <br />20 <br />Z CV <br />T <br />IO <br />C) <br />T <br />� <br />OM <br />T <br />hi <br />w <br />N <br />\ <br />�i to <br />o <br />Z <br />CIO <br />Z <br />:3 <br />E <br />`' <br />a <br />E <br />0 _j <br />Q o <br />c <br />JOB <br />NO: <br />20-3575 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />u;l 1111 111 , I ,, 1 1 Li il14, dl d a;L' , 11 1I,, IAL: 1 1 . 1 1 1 1 1 1 11 <br />