THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />WEATHER <br />RESISITIVE <br />BARRIER <br />WEATHER <br />1/E BARRIER & <br />iARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHING <br />SHEATHING BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI; <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weat <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />S <br />DO NO- <br />BOTTO <br />P1 Amr--1 <br />4SHING <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />�- SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6 USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING <br />1 <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />8 (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />I L/'1VI IIIVt.I r L Ql 1111I <br />2 <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC <br />R703.2.1 AND FBCR 703.7.3 <br />Detail Instructions <br />Refer to the number marked as #Q in each detail that corresponds to the <br />numbered items in the list of Instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROCK- <br />8" CMU <br />4"OR8"CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD <br />VINYL SHOWER PAN <br />SELF-ADHEF <br />1'-4" PER PLAN <br />SHOWER SEAT <br />lei <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />Z <br />CL <br />w <br />d <br />rn <br />rn <br />w <br />U <br />W <br />W <br />O <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />PLASTER STOP - <br />CONTINUOUS BACKER - <br />ROD & SEALANT <br />A <br />E0 <br />la <br />0 <br />0 <br />0 <br />0 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />V�, <br />Q <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />THROUGH SELF -ADHERED <br />FLASHING SELF -ADHERED FLASHING <br />SCORED <br />RELEASE PAPER <br />(BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />a <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />�Ground� <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS <br />NATU <br />DO NI <br />DRIP <br />ACCE <br />SOFFIT/CANTILEVER <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS\� <br />2AL FRAMING <br />2AL SHEATHING <br />3AF <br />PLANE WRB <br />AK WRB <br />FLASHING REQUIREMENTS <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall include <br />flashing as described in Section R703.4. A water -resistive barrier is described as a material behind an exterior wall covering that is intended to <br />resist liquid water that has penetrated behind the exterior covering from further intruding into the exterior wall assembly. An exterior wall covering <br />is described as a material or assembly of materials applied on the exterior side of exterior walls for the purpose of providing a weather -resistive <br />barrier, insulation, or for aesthetics, including but not limited to, veneers, siding, exterior insulation and finish systems, architectural trim and <br />embellishments such as cornices, soffits, and fascias. <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches <br />(152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a <br />manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based sheathing, shall include a <br />water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The individual layers shall be <br />installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance with Section R703.4) <br />intended to drain to the water -resistive barrier is directed between the layers. <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance equal to or greater than <br />that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially nonwater-absorbing layer or designed <br />drainage space. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity <br />or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. All <br />exterior fenestration products shall be sealed at the juncture with the building wall with a sealant complying with AAMA 800 or ASTM C920 Class <br />25 Grade NS or greater for proper joint expansion and contraction, ASTM C1281, AAMA 812, or other approved standard as appropriate for the <br />type of sealant. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. Approved corrosion resistant flashings shall be installed at the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish <br />or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings shall <br />comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following: <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2. In accordance with the flashing design or method of a registered design professional. <br />1.3. In accordance with other approved methods. <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMAMDMA 400. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco <br />copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />0 <br />0 <br />CV <br />�t- <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />e <br />W <br />Q <br />� <br />V E c(o <br />O v. N <br />O00 p7 <br />t S <br />M N N N <br />0 J <br />� aND LL <br />0 <br />0 <br />'� <br />.2 -a <br />J <br />7 � <br />J * W <br />- J n. <br />u' <br />M <br />Q <br />N <br />rn ,� M I <br />emuJ <br />u_ <br />W ' N <br />as <br />0Co <br />Z <br />mm0 <br />@�� <br />'5 0 r- <br />m <br />W <br />Z <br />LLW <br />2 E T rn <br />N° <br />s p a <br />0 co <br />N M Z <br />a O 5 <br />Z <br />❑❑❑ <br />W <br />M <br />M 8 <br />co <br />po N O <br />_ <br />z S <br />¢ v <br />J th <br />d N <br />- M <br />Z `Oo <br />0 <br />v <br />(D <br />(D <br />_ <br />� <br />U..) Y <br />w n <br />o <br />LU <br />L <br />O <br />rtr/^^1 <br />v ' <br />o <br />N <br />w. <br />� <br />� o <br />w rn <br />as <br />ME <br />� MEE <br />0 8 <br />ml <br />_ C <br />U o <br />c M ID <br />¢ o <br />a <br />Q <br />o <br />co <br />JZ <br />W <br />co <br />o <br />� <br />LL <br />E <br />zo <br />o� <br />>N <br />¢o <br />i1 <br />E d <br />w ? <br />z0 <br />❑ a <br />rd <br />o <br />�a XCID <br />oo oz <br />< <br />o E <br />CD <br />ao <br />Qo <br />Qa <br />x <br />�w <br />L <br />G <br />0 <br />Y <br />Nm <br />0 <br />'0 <br />0 <br />Z- <br />A <br />J <br />< <br />aw <br />z z <br />rn <br />M <br />. <br />oa <br />z <br />30 <br />V <br />Io <br />a <br />W <br />a� <br />0 <br />o <br />d <br />� <br />za <br />a° <br />c § <br />=N <br />0 <br />= <br />> � <br />^L1 <br />m <br />W <br />CU <br />N <br />LL <br />N <br />O <br />CD <br />�✓ m <br />= <br />ACV <br />a) <br />J <br />r <br />d7 <br />= <br />O <br />r <br />N <br />co <br />ui <br />M <br />M <br />C) 1 <br />co <br />0 <br />Z <br />z <br />E O <br />m <br />a <br />E <br />0 <br />U <br />¢ p <br />_J <br />JOB <br />NO: <br />20-2751 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />W P <br />