My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3071 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3071 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:14:45 AM
Creation date
2/25/2025 9:36:44 AM
Metadata
Fields
Template:
Building Plans
Street #
3071
Location
Kresterbrooke Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
19703
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIMPSON HGAM11 <br />W/ <br />(4)1/4"xl 1/2" SDS <br />SCREWS <br />TO BLOCKING & (i <br />1/4"x2 3/4" <br />TITEN TO CMU <br />SEE STRUCTURAL NOTES AND TOENAIL W/ (2)16d NAILS BACKNAIL W/ (2)16d NAILS SIMPSON H1OA w/ (18) BACKNAIL w/ (2)16d NAILS SIMPSON H1 OA w/ (18) SIMPSON SP4 wl (6)10d x <br />NAILING SCHEDULE FOR 10d x 1 12" AT EA. <br />2"x4" OUTLOOKER SEE STRUCTURAL NOTES AND 1 Od x 1 12" AT EA. 2"x4" SEE STRUCTURAL NOTES 1 12" AT EA STUD (USE BACKNAIL w/ (2)16d NAILS SIMPSON H10A w/ (18) <br />SHEATHING DETAIL OUTLOOKER OUTLOOKER SP6 FOR 2x6 WALL USE 10d 1 12" AT EA <br />@ 24" O.C. <br />NAILING SCHEDULE FOR OUTLOOKER <br />AND NAILING SCEDULE <br />@ 24" O.C. HDETAIL <br />TOP CHORD <br />SHEATHING DETAIL <br />FOR SHEATHINGH <br />BLOCKING FOR <br />• <br />FIRST FOUR <br />ROWS OF <br />45° t <br />„ <br />24 MAX. <br />TOP CORD BLOCKING 45°t <br />2X4 CONT"L" BRACE <br />TOP CORD BLOCKING <br />TRUSSES @ <br />SIMPSON H10A w/ (18) <br />FOR FIRST FOUR <br />FASTENED W/ (2)10d 3" <br />FOR FIRST FOUR ROWS <br />EDGES OF 2x4 CRO BRACE <br />10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24" O/C. CMID HEIGHT <br />OF TRUSSES @ EDGES <br />SHEATHING APPROX. 8" FROM <br />OUTLOOKER <br />EDGES OF <br />OF SHEATHING TYPICAL <br />TYPICAL @ RIDGE FASTENED AT <br />BRACE TO EXTEND <br />SHEATHING TYP. 2X4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />48" O.C. EACH JOINT W/ (3) 10d <br />A WEB <br />AT LEAST <br />@ 8'4" O/C. <br />EXTEND AT LEAST 90% OF <br />' <br />MAX. & (2)10d TOE NAILS @ <br />2x4 CROSS BRACE <br />WEB LENGTH & NOTCH AT <br />EA. END @ 48" O.C. <br />A <br />LENGTH (SEE TABLE) <br />(SEE <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />2x6 P.T. <br />GABLE TRUSS <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />• <br />SILL <br />1/2" CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROM LEDGER TO <br />; <br />7/16" OSB SHEATHING <br />& (2)10d TOE NAILS @ <br />BLOCKING <br />ATTACHED W/ 10d <br />EA. END <br />NAILS @ 6" O.C. EDGES <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1OdX3" @ 3" O/C <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />1/2" CDX PLYWOOD OR 7/16" <br />THROUGH CHORD <br />CORD ATTACHED W/ (2) 16d TOENAILS <br />OSB SHEATHING ATTACHED <br />10d NAILS O.C. <br />INTO 2"x6" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />w/ @ 6" <br />EDGES AND 12" O.C. FIELD <br />2x4 PANEL BLOCKING @ <br />2x4'T" ON TOP OF PANEL BLOCKING, <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />O.C. FOR THE FIRST (4) <br />FASTEN WITH 10dx3" @ 4" 0/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />�� „ <br />NOTCH L BRACE HERE <br />ROWS OF TRUSSES FRO <br />@ 48" O.C. <br />5/8" x 10" "J" BOLT @ 48" O.C. <br />WEEP SCREED <br />EA. END TYP. TOP & <br />MOISTURE BARRIER <br />BOTTOM ATTACHED w/ (2 <br />5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM <br />SIMPSON HETA20 w/ (8)1Odx1 1/2" NAILS AT 6'-0" <br />INSTALLED PER MANUF. <br />16d TOENAILS <br />PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK -IN <br />MOISTURE BARRIER <br />10dx1 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7)1 Od NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4) 1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL SECTION <br />1 <br />O.C. MAX) w/ MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />GABLE WEB <br />SECTION <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />1Od NAILS & (4) 1/4"x2 1/4" SCALE: N.T.S. <br />S5 <br />SCALE: N.T.S. <br />S j <br />TITEN ON OUTSIDE <br />SIMPSON H10A <br />w/ (18) <br />BACKNAIL W/ (2)16d NAILS <br />7 <br />L <br />SP8 FOR 2x8 WALL) <br />SEE STRUCTURAL <br />NOTES x ' <br />OUTLOOKER <br />AND NAILING SCHEDULE <br />FOR SHEATHIN <br />DETAIL <br />2x4 OUTLOOKER <br />@ 24" O/C <br />2x4 OUTLOOKER @ 24" <br />TOP CORD <br />O.C. (OPTIONAL -SEE <br />4" MAX. <br />BLOCKING FOR <br />ELEVATIONS) <br />FIRST FOUR ROWS <br />DOUBLE TOP PLATE <br />OF TRUSSES @ <br />2x4 CROSS BRACE APPROX. 8" <br />2"x4" CROSS BRACE <br />24" MAX. EDGES OF <br />FASTENED <br />FROM RIDGE FASTENED AT <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />EACH JOINT & (2 <br />RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />TOE NAILS @ EA. END <br />EACH JOINT W/ (2) <br />AT LEAST 90% OF WEB <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />GABLE TRUSS <br />SECTION FOR SIZE &SPACING) <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR <br />1/2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />(2)16d <br />7/16" OSB SHEATHING <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />ATTACHED w/ 10d NAILS <br />W/ 10d NAILS @ 6" O.C. EDGES <br />AND 12" O.C. FIELD <br />TRUSSES FROM EA. <br />END TYP. TOP & <br />NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />(2)16d NAILS <br />BOTTOM ATTACHED <br />48" <br />2x BLOCKING <br />W/ (2)16d TOENAILS <br />2x4 "T" ON TOP OF PANEL <br />BLOCKING, FASTEN WITH <br />M <br />2x4 "T" ON TOP OF PANEL <br />SIMPSON <br />1Odx3" @ 4" O/C <br />HGAIOKT w/ (4)1/4"x1 1/2" <br />BLOCKING, FASTEN WITH <br />SDS SCREWS <br />TO TRUSS & (4)1/4"x3" <br />10dx3" @ 4" 0/C <br />SDS SCREWS <br />TO PLATES AT 36" O.C. <br />SIMPSON SP2 w/ (12) 10d <br />2x4 LEDGER (MATCH BOTTOM <br />NAILS AT EACH STUD <br />CHORD SLOPE OF ADJACENT DBL. TOP PLATE <br />TRUSS) STUD WALL (SEE TYP. SEC.) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />1 Od x 1 12" AT EA. 2x4 OUTLOOKER <br />REFER TO DETAIL J <br />SEE STRUCTURAL <br />OUTLOOKER @ 24" O/C <br />ON SHEET S5 FOR <br />^ <br />NOTES AND NAILING <br />TOP CORD <br />X-BRACING, AND TOP <br />N <br />SCHEDULE FOR <br />BLOCKING FOR <br />CHORD BLOCKING <br />INFORMATION <br />`� <br />� <br />°° <br />SHEATHING DETAIL <br />FIRST FOUR ROWS <br />OF TRUSSES @ <br />2"x4" CROSS BRACE <br />24" MAX. EDGES OF <br />-WOOD TRUSSES <br />;° <br />;° <br />APPROX. 8" FROM <br />SHEATHING TYP. <br />RIDGE FASTENED AT <br />Zvi "L" BRACE TO EXTEND <br />• 2x4 RAT RUN BRACING <br />; <br />EACH JOINT W/ (2) <br />AT LEAST 90% OF WEB <br />AT 24" O.C. ON TOP OF <br />10d & (2)10d TOE <br />LENGTH (SEE TABLE) <br />BOTT. CHORD FOR 4 <br />NAILS @ EA. END <br />GABLE TRUSS <br />TRUSS SPANS <br />ATTACHED W/ 2 -16d <br />2x4 PANEL BLOCKING <br />1/2" CDX PLYWOOD OR 7/16" <br />AT EA. TRUSS JOINT <br />(2) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 4" LAMINATIONS W/ (1) ROW <br />(3) 2" x 6" LAMINATIONS W/ (2) ROWS OF <br />@ 48" O/C FOR THE <br />FIRST (4) ROWS OF <br />OSB SHEATHING ATTACHED <br />(2)16d NAILS W/ 1 Od NAILS @ 6" O.C. <br />OF STAGGERED 10d COMMON WIRE NAILS <br />OF STAGGERED 30d COMMON WIRE NAILS <br />STAGGERED 30d COMMON WIRE NAILS <br />TRUSSES FROM EA. <br />E ES AND 12" O.C. FIELD <br />2x4 BLOCKING @ 24" <br />(D = 0.148", L = 3") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />(D = 0.207", L = 41/2") OR EQUAL <br />END TYP. TOP & <br />JACK TRUSS <br />O/C w/ (2) 16d <br />TOENAILS @ EA. END <br />NOTES: <br />BOTTOM ATTACHED <br />SEE PLAN FOR <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL <br />w/ (2)16d TOENAILS <br />CONNECTION <br />MASONRY WALL OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) <br />ARCHITECTURAL FINISH 2) ALL NAILS PENETRATE AT LEAST 3/4 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4" DIA. x 7" LAG SCREWS OR EQUAL 2x47" ON TOP OF PANEL <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3- <br />PLY) BLOCKING, FASTEN WITH 2x4 BLOCKING WI <br />10dx3" @ 4" 0/C (2)12d TOENAILS <br />Cn <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION <br />EXT. WALL CONN. @COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />z NON - LOAD BEARI G LOCATIONrD B.U.C., SAME NUMBER OF ROWS, SAME SPACING) SECTION g <br />SEE TYP. WALL SECTION FOR SCALE: 3/4" = V-0" S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 <br />, ADDITIONAL INFORMATION. <br />0 <br />LN <br />1 <br />LO <br />N <br />0 <br />N <br />MINIMUM 2x <br />CROSS BRACING <br />a <br />LO <br />(SEE PLAN FOR <br />N <br />LOCATIONS) <br />(2)16d PER <br />I: JOINT <br />.81 1 L CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />0 <br />CROSS BRACING DETAIL ri <br />i <br />SCALE: N.T.S. S5 <br />4 <br />°0 12 <br />6.9 MAX. <br />2"x4" OUTLOOKER @ 24" - <br />O.C. W/ (2)10d PER JOINT <br />10dx3" O/C @J 2"x4� <br />TOENAIL 6" O/C RUNNE <br />W/ (2)16d TYPICAL <br />NAILS <br />ALTERNATE NON -DROP <br />GABLE END DETAIL <br />SCALE: N.T.S. <br />1 GABLE TRUSS <br />"L" BRACE W/ 10d @ 4" O.C. <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />S5 <br />S5 <br />• . . d II ' ° a • I . ■ d i l d. • ° _ • �I • \ e 1 TI e a a II d •� a 18 • • a • 11 • a • d ♦ �I . • • d Ile ' • • II •• • ae A. d.• <br />'-CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />SCALE: N.T.S <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />S5 SCALE: N.T.S. S5 <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES <br />MINIMUM (2)16d PER JOINT MINIMUM 2x4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL <br />SCALE: N.T.S <br />6" OVERLAP <br />M <br />S5 <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />a <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)1 Od <br />WOOD TRUSSES TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />0 <br />z <br />w <br />BRACING w/ (3)1 Od x 3" AT <br />• EACH CONN. @ 24" O/C <br />SIMPSON HGAMIOKTA w/ (4) MOISTURE BARRIER <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4) 1/4"x2 3/4" BOND BEAM <br />TITEN TO CMU <br />MASONRY WALL <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />10d NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4'7" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 10d NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB J <br />SINGLE "L" BRACING DETAIL 6 <br />SCALE: N.T.S. S5 <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE J <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 n ICONTINUOUS BOTTO CHORD BRACING 2X4 MIN. <br />L! <br />ARCHITECTURAL FINISH NOTE: <br />EXT. WALL CONN. @ NON - LOAD <br />BEARING LOCATION UNEVEN CLG. <br />rE <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5 <br />ADDITIONAL INFORMATION. <br />"L" BRACING REQUIREMENTS <br />ARCHITECTURAL FINISH NOTE: <br />EXT. WALL CONN. @ NON - LOAD <br />BEARING LOCATION UNEVEN CLG. <br />rE <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S5 <br />ADDITIONAL INFORMATION. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />"L" BRACE <br />2"x6" (U.N.O.) <br />"L" BRACE <br />24" <br />0'0" .3141 <br />3'-0" - 6'4" <br />V-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2'W" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4)1/4"xl 1/2" SDS <br />SCREWS TO TRUSS & (4) 1/4'x3" SDS SCREWS <br />TO PLATES (TYP.) <br />i—GABLE TRUSS <br />`STUDS @ 16" O.C. <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 w/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />0 <br />Cr <br />0 <br />a <br />CORNERJACK <br />Y <br />W <br />z <br />0 <br />0 <br />HIP FRAMING REFERENCE PLAN <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2)'T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />/TOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)10d AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />LO <br />CD <br />z o <br />z�z <br />Q <br />z <br />U)V) <br />0 <br />(D <br />Q <br />+-+ w <br />(D(Z <br />p <br />•U — <br />U c <br />c/ <br />s <br />U <br />m <br />a,-w <br />i — <br />t° <br />N <br />O O <br />_ <br />- <br />U. <br />:9 <br />c <br />n -. o <br />BD. <br />Boc <br />i <br />N gR0 �1V <br />�e <br />o <br />'ll • [A u_ <br />Z <br />� � <br />fl i <br />oac <br />t9• � <br />ROFESS%W4 <br />❑ <br />To the best of knqq���1JJ ormation, and <br />belief, the structural p J j�1iiO bons contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />1f <br />O <br />O <br />Z fV <br />OIL <br />> V) M CD <br />M <br />a (n M Ln <br />a cn •� �t- <br />V7 Z <br />Q LL <br />�M <br />0�V Q00 <br />< <br />E � <br />Z <br />W <br />J � <br />Z <br />W� <br />Za <br />tY <br />? ce <br />Lu <br />�ZZ <br />Q <br />Z <br />"9 Z,f <br />10'. <br />J <br />r,® <br />go <br />z <br />(v <br />I /'1 <br />w <br />in 3 <br />x <br />-0 <br />N <br />o <br />U <br />_ <br />0 <br />z <br />Q <br />LLu <br />U g <br />he r <br />0 <br />Uo <br /><�o <br />Q <br />� <br />Z <br />Z <br />� <br />�u <br />aQ <br />J <br />� <br />z <br />LJj <br />2: <br />Z <br />zo <br />a <br />�g <br />O <br />m <br />O <br />fV <br />00 <br />Z <br />2 <br />< w <br />(Al <br />SCALE : AS NOTED <br />DATE : 3/19/2018 <br />TECH: MJAMES <br />VERSION N0. 5n0_ <br />SHEET NO. <br />S5 <br />