Laserfiche WebLink
0 <br />9-1 <br />v <br />0 <br />a <br />LO <br />i <br />N <br />it <br />I <br />00 <br />E <br />TYP @ 2 STORY <br />J <br />S6 H.B. <br />iv <br />N <br />= <br />0 <br />5-SH <br />16" DEEP <br />- <br />- <br />D <br />P----- <br />N <br />s3 <br />F — — — — — — — — — — — — <br />266 BY <br />— <br />I <br />24 244 <br />REF. <br />2x6 WALL <br />I I <br />50 <br />I I <br />I <br />--- <br />—-----1 -0 <br />268 <br />EOPT. <br />KITCHN <br />H1 <br />o <br />I I <br />I I <br />I <br />I <br />ADM <br />3 <br />8,_8, FL.� T �,LG.! <br />I I <br />I <br />tv <br />o <br />Till <br />I 0 I <br />I <br />CC <br />I w I <br />I <br />3 35 36 <br />— <br />OLu I <br />I <br />- <br />tI_J I <br />1 <br />r-r <br />Lu <br />0 <br />&----------- <br />N <br />- <br />LLEDGE <br />— OF SLAB " <br />I <br />NBEYOND WALL <br />x I <br />I <br />4'-0" <br />6'-2" <br />V-6" <br />4'-8" <br />20'-8" <br />I I <br />I <br />r <br />2 CAR GARAGE <br />I I I <br />DINING ROOM <br />8'-8° FLAT CLG. <br />PAT I Oo <br />I I I <br />8'-8" FLAT CLG. <br />I I I <br />(D 0 CARPET <br />BUILDER TO PROVIDE <br />I I I <br />I I I <br />o 002 <br />_g" APPLIANCE PROTECTION <br />CO o <br />WHEN REQUIRED PER FBC <br />I p I I <br />to <br />0 (3)2X4#2SPF W/ <br />I S3 I I <br />L - - - - - -- --- <br />in <br />(3)16d TOENAILS <br />CC (3) 2X4 #2 SPF W/ <br />N <br />BASE <br />S3 (3)16d TOENAILS <br />4 <br />(3) 2X4 #2 SPF W/ <br />W. H. <br />@ BASE <br />(3)16d TOENAILS @ <br />BASE <br />-- ------ <br />TYP @ 2 STORY <br />CrI XI _ <br />FOYER <br />(2) #5'S <br />J <br />0 01 g <br />0 0 <br />3068 i <br />8'-8" FLAT CLG. <br />S6 <br />LL Ui I �' <br />TILE B I <br />Q <br />16' 4s" <br />3'-8" 6 3'-8" i. 3'-6" <br />6 6'-0" '-2" ' 1 <br />TRY <br />FV <br />2068 B.F. <br />— — _ HDR AT T-4" — _ — 8'-8" FLAT CLG. <br />5-SH °O <br />T <br />2x6 WALL <br />_. <br />(2) #5'S <br />_ <br />FR I <br />N <br />i', A) 2 <br />�� <br />G N o <br />S3 <br />� <br />pl <br />J <br />_ <br />(3) 2X4 #2 SPF 8'-8 FLAT G.1 , <br />FLEX `� <br />7 <br />FAMILY ROOM <br />W/ (3)16d <br />8'-8" FLAT CLG. _ <br />TOENAILS @ <br />12 <br />CARPET I O <br />8'-8" FLAT CLG. <br />BASE - -- <br />P <br />CARPET <br />42" SLOPING 11 <br />N <br />HALF WALL 10 <br />FLOOR G.T. <br />-- -- <br />_ 9 <br />I <br />io <br />Q, <br />00 <br />_ <br />__ _ _ _ <br />4 5 <br />AC PAD AC PAD <br />I I I 1 1 I I I$ <br />I I I IUp h6Rl I I C111 <br />M <br />3 <br />TYP @ 2 STORY <br />I S6 <br />I I I I I 1 I <br />H.B. <br />J <br />S6 <br />TYP @ 2 STORY <br />(3) 2X4 #2 SPF W/ (3)16d J 1 <br />TOENAILS @ BASE 8 <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) -1 3/4" X 9 1 /4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 4 X 251 <br />S.H. <br />13 <br />20X38j <br />184X37i <br />S.H. <br />14 <br />20 X 50 <br />18 X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 J X 6Y j <br />S.H. <br />16 <br />20X72 <br />18jX71j <br />S.H. <br />j 32 <br />27 1 /4 X 26 <br />26 X 25 <br />S.H. <br />433 <br />271 /4 X 38 j <br />N/A <br />S.H. <br />j 34 <br />27 4 X 50 1 <br />N/A <br />S.H. <br />433 <br />N/A <br />26 x 37 1 <br />S.H. <br />434 <br />N/A <br />26 x 50 <br />S.H. <br />435 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />436 <br />27 J X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 j X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 1 X 38 tj <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 1 <br />36 j X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37jX72 <br />364X711/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73 4 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 � X 25 � <br />S.H. <br />33 <br />54 X 381J <br />52 4 X 37 J <br />S.H. <br />34 <br />54 X 501 <br />52 4 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 j X 62 j <br />S.H. <br />36 <br />54 X 72 <br />52 } X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />• Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Door between <br />garage and residence shall be equipped with solid doors not <br />less than 1 3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1 3/8" thick, or 20-minute fire -rated doors. <br />• Duct Penetration. Ducts in the garage and ducts penetrating <br />the walls or ceilings separating the dwelling from the garage <br />shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no <br />openings into the garage. <br />• Other penetrations shall be protected as required by section <br />R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the opening of an operable window is <br />located more than 72 inches above the finished grade or surface <br />below, the lowest part of the clear opening of the window shall be <br />a minimum of 24 inches above the finished floor of the room in <br />which the window is Iocated.Operable sections of windows shall <br />not permit openings that allow a 4-inch-diameter sphere where <br />such openings are located within 24 inches of the finished floor. <br />Chapter 45 Private Swiming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db a at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />see Sht. SN1 for installation detail. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED- EXPOSURE "C" <br />K <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />OE <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />OG <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A1" <br />1ST FLOOR LIVING AREA 1093 <br />2ND FLOOR LIVING AREA 1491 <br />LIVING TOTAL 2584 <br />GARAGE 427 <br />FRONT ENTRY 35 <br />TOTAL AREA 3046 <br />0 <br />INSULATION REQ. <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />U <br />ao) <br />z� <br />Q <br />a <br />z <br />tJ7 U' <br />-J w <br />*U — <br />0 LLJ <br />Ch <br />E <br />U <br />W <br />' ~ <br />Cl) <br />C RiLa -0 Cl) <br />0,9 N <br />U <br />"w <br />moo <br />1i11Ltyff( <br />N <br />' ¢ o <br />Al1 <br />" `—" , <br />o <br />� <br />';. <br />1�/ •• G <br />o Q ���h <br />• <br />10 <br />II-4 <br />N LL LO <br />c9 <br />6� <br />ca N���\ <br />us In N< 1l 111 t 0 <br />O U <br />o <br />U <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />1< <br />O <br />O <br />Z (V <br />O4a)I-, <br />00 <br />z <br />t/-�t (n M <br />M <br />Q U <br />0 <br />C Ln <br />LL <br />Q ^ <br />oC U- � <br />CL '-I <br />Q <br />� <br />z�M <br />WJ <br />l00 <br />z <br />za <br />a <br />I— <br />�a� <br />�?OU <br />1;7g <br />Z <br />OJ <br />a <br />L <br />Cr <br />g <br />8 <br />zz <br />1 ` <br />1) <br />Ln <br />LL <br />0 <br />,d <br />U) <br />z <br />9 <br />= <br />°' <br />o� . <br />pz <br />4 <br />�QLUo <br />Q <br />Z <br />912 <br />J <br />Lr) <br />r� <br />z <br />LJJ <br />ZZ <br />a z <br />Z <br />0 <br />*k <br />m <br />O <br />06 <br />Z <br />j <br />W <br />�00 <br />o <br />'.4g <br />LLu <br />SCALE : AS NOTED <br />DATE : 3/19/2018 <br />TECH: MJAM ES <br />VERSION NO. 5w0 <br />SHEET NO. <br />1.0 <br />