My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3083 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3083 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 8:59:12 AM
Creation date
2/25/2025 9:37:06 AM
Metadata
Fields
Template:
Building Plans
Street #
3083
Location
Nubbin Ridge Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
22501
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"N11 ;V:I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />I . <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />K* <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />I—O <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />tOr EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />R9 PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />99 <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />10 #14 copper to lights s outlets <br />NEMA 1 00 #12 copper to 20 amp dos <br />200 AMP <br />01 #10-2 copper to WH <br />No #10-3 copper to Dryer <br />METER <br />n r 2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />VERIFY METER LOCATION <br />WITH BUILDER <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />0 <br />N <br />O <br />N <br />r.. <br />N <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and speciflcatfons contained within these <br />drawings amply with the 2017 <br />Florida Buikfing Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />E <br />0 <br />Lo <br />J --r <br />N ^ C U. LL <br />.:"'OtI J it W W <br />•g <br />0) <br />LL u- LL a. d <br />(n N M W fA <br />a 0' u! <br />Z <br />13�'% <br />Qa� O <br />0 ,0 ° <br />C09 <br />W <br />W <br />�m°o <br />Wow m <br />2E1'O' ja0-83 <br />IL <br />2 <br />N N <br />N co Z 0 O <br />J <br />a°� <br />Z <br />1- <br />❑❑❑❑ <br />W <br />Z <br />a <br />tl <br />N <br />z <br />X <br />.0 <br />., , <br />Ina <br />w e <br />N <br />_U „ <br />L? <br />U'= <br />_ <br />O <br />M <br />ch <br />i <br />z <br />E <br />o <br />w� <br />S' <br />? ® <br />p <br />V <br />t� <br />_ <br />o E <br />(aate <br />Xo <br />Eo <br />z <br />oa <br />Qo <br />x <br />Z <br />O � <br />% z <br />$ <br />wz <br />� <br />C <br />c <br />N <br />o <br />ce` <br />i <br />Z <br />W <br />8� <br />a <br />Z <br />x <br />M, <br />j <br />�o <br />y <br />� <br />2 $ <br />z <br />.2N <br />:3= <br />rn <br />B <br />19 <br />� <br />^L` <br />W <br />.> <br />c <br />CO <br />n/ <br />tt; <br />Q <br />LPL 3s <br />o� <br />0 <br />CL <br />C m <br />r <br />O <br />o <br />qct <br />O) <br />Z (V <br />LO <br />r <br />= M <br />0000 N <br />O r <br />r <br />E <br />c, <br />0 <br />M <br />Z <br />Z <br />E <br />E <br />rn <br />o w <br />c <br />c <br />0- <br />U J <br />Q p <br />JOB <br />NO: <br />20-0561 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.