Laserfiche WebLink
3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />T.O.M. <br />HDR HGT. <br />TEXTURED <br />o CEMENTICIOUS <br />co co FINISH ON C.M.U. <br />io (TYP.) <br />F.FL. <br />N <br />N <br />r <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />12 <br />5� <br />10 J _ 6-0" <br />12 <br />5� <br />T-W RIDGE VENT <br />OVERHANG <br />BE CENTER[ <br />ON DOOR <br />12 <br />5� <br />12 <br />zz:::�15 <br />— — T.O.M. <br />_ HDR HGT. <br />_1-0 <br />lt <br />F.FL. <br />REAR ELEVATION - 61 <br />14'-0" RIDGE VENT <br />SCALE: 1 /4"=V-0" <br />ME <br />,T•; <br />12 <br />�5 <br />RIGHT ELEVATION - 61 <br />1/4"=1'-0" <br />Z-O" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />"G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"*ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />Il illlllj <br />\\\\11111 <br />M!irr <br />Q. r.• E`` <br />6 0 <br />U� <br />��52. <br />'•. F <br />1.0� <br />iJrrri,'✓r/'�?O F E S S`O` ; <br />\\ <br />�/f1111111111 <br />To tit best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings oomply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />H <br />E <br />OPn? <br />p O , a J <br />MN ap U. U. <br />�Nt71 <br />aW�LLLLa <br />C0alM WLL, <br />ai-aU, <br />s, <br />Z <br />0m..i <br />> Y <br />_ <br />��a �E0, <br />W <br />rn `r co <br />ZOf <br />N O N <br />z g 3 <br />AlSLL0 <br />3cn <br />_ <br />U ❑❑❑❑ <br />W <br />Z� <br />z <br />Z� <br />a v <br />a <br />N <br />Z <br />LU <br />0 <br />4 <br />W <br />o <br />�_ I <br />U <br />c <br />Q <br />0 <br />M <br />z <br />w <br />_J <br />u0- ¢ <br />3 <br />c EE <br />0.g <br />EU�a <br />3iZ <br />— <br />o E <br />�o <br />0 <br />S <br />� <br />z <br />N <br />Wo <br />�o <br />rc� <br />�z <br />(Q <br />C <br />�� <br />�x <br />U <br />�LL <br />z�� <br />N( au <br />�� <br />W <br />� <br />8 <br />WLL <br />U <br />�W <br />� <br />wLL <br />_p <br />o <br />wel <br />pW <br />ZI�� <br />G <br />U <br />1 <br />J <br />! <br />M <br />L <br />M <br />N <br />.� <br />c <br />CD <br />co <br />aC <br />.2 <br />v <br />CO <br />c <br />TCD <br />N <br />r <br />CrIll, <br />.� <br />Z O <br />Lao) <br />LO <br />E <br />�' <br />a N <br />M N <br />W T <br />° <br />Z <br />to <br />c <br />a <br />E Q <br />U <br />U) <br />c <br />_J <br />JOB <br />NO: <br />20-0560 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.2 <br />