My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3095 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3095 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:16:03 AM
Creation date
2/25/2025 9:37:26 AM
Metadata
Fields
Template:
Building Plans
Street #
3095
Location
Nubbin Ridge Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
22505
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FF.1 <br />1 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to beat 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 21 T <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance With FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station Cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and Windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying With UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />*WP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />© <br />RECESSED LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />200A INDOOR PANEL <br />#14 copper to fights & oughts <br />NEMA <br />00 AMP 1 <br />2Iq A012 copper to 20 emp cos <br />#10.2 copper to WH <br />#10-3 copper to Dryer <br />0 or 4/0 SER Afu <br />200 amp <br />150amp =jr <br />sconnL#4GROUNDING <br />POWER CO. FEED <br />INTERSYSTEM <br />Bare Cu Ground <br />BONDING <br />WIRE <br />TERMINATIONPER_y <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP <br />GFI DISC. <br />DEDICATED RECEPTACLE <br />FYIR UIr PnWOVI= RANr;F <br />0 <br />EXHAUST FAN <br />Mr-1. VERIFY LOCATION <br />GFI <br />_ _ _ _ J <br />Ll <br />ELECTRICAL PANEL <br />EXHAUST FAWLIGHT COMBINATIONdb <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />1111111 <br />RECEPT. <br />CH <br />CHIMES (OPTIONAL) <br />FOR ALARM VERIFY METER <br />SYSTEM LOCATION WITH <br />P-0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />BUILDER <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60- A.F.F. <br />TO <br />THERMOSTAT <br />IDI <br />ELECTRIC METER <br />a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL PLAN — ELEV-131 <br />SCALE:1/4'=1'-0" <br />0 <br />0 <br />N <br />N <br />O <br />To the best of Ile Engineer's knowledge, information and belief, <br />the stnkturai plans and specifications contained within time <br />drawings comply with the 2017 FWda Building Code - <br />Residential Oth Edition. Engineers signature and seal is only for <br />the structural engineering portions of fhe drawing pages bearing <br />EnginWs signature and seal. <br />a <br />g chi <br />r- JV <br />M N Nr5ll m u- <br />r LL a�LLLL <br />ig <br />au- <br />z <br />Cn t3 5 a. <br />i C ll: iii a a. Y <br />zQ <br />EL �$ <br />vv)0) OtYZHO <br />mmso <br />W <br />W <br />IL <br />.24 <br />co o rr• ¢ <br />2 E T _j o o� 0 <br />Sg� rn <br />ppL <br />Zd <br />N F J i <br />z <br />Q <br />°� ❑00❑ <br />W <br />z � <br />z <br />z g <br />a <br />� <br />N <br />zCSQ) 0 <br />LU <br />OLLI <br />vLn <br />V <br />00 <br />NZ� <br />W <br />� <br />E <br />O <br />rrzCLsi <br />Qce <br />I— <br />� <br />° o <br />wU <br />ZoM <br />N f� <br />i <br />az�Z <br />g o <br />w <br />w ro <br />03 <br />o <br />Z <br />N J <br />om <br />�m <br />W <br />U <br />9 <br />$o <br />i <br />�LL <br />�U <br />aw <br />ai <br />L <br />CN <br />CN <br />Q <br />vt <br />C) <br />(0 <br />T <br />I <br />Z C <br />CY) <br />T <br />E <br />^ <br />CN <br />M N <br />z° <br />Z <br />' <br />O <br />r <br />v w? <br />cc <br />c <br />C <br />c <br />JOB <br />NO: <br />20-0560 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.