ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY; <br />BON <br />TERMINATIOP <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />tpper to lights 3 outlets <br />>pper to 20 amp Me <br />Copper to WH <br />copper to Dryer <br />l Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />OGFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4 � <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />�{ <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />'wo <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />1-[a]P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />@ <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />J <br />ELECTRIC METER <br />JE!!3- <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />A9 <br />(1) PHONE LINE, (1) DATA PORT <br />N1r- - ' - <br />6061.j IreL.Ij I <br />DISC <br />WP <br />GFI <br />PATIO <br />WP <br />GFI <br />H.B. <br />I I I <br />I I <br />/ I I <br />FAMILY ROOM---, <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />\ `\ _M_ <br />-�I <br />I <br />I <br />)GFI GFI <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />TO LIGHT <br />AND <br />SWITCH <br />ABOVE <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />l/ <br />FLEX <br />I <br />loll FOYER <br />dh <br />C.M <br />\ PENDANT AS CH 0 <br />\PER SPECS <br />DINING ROOM _ <br />2 CAR GARAGE <br />=1 @ 44" <br />A.F.F. <br />F------------ <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />ur-I q 44.. GAR. <br />A.F.F. DOOR <br />I GFI n GFI <br />l � I <br />/ / I <br />I <br />I <br />I <br />KITCHE <br />� I <br />I <br />I <br />I � I <br />REF. j <br />OPT. - VERIFY LOCATION L _ IRRIGATION — — — — <br />FI : -- - - ELECTRICAL PANEL GFI @ 44" A.F.F. <br />VERIFY METER H.B.+ <br />LOCATION WITH <br />BUI DER 12'-0" <br />10 <br />WP <br />I <br />I <br />I <br />I <br />I <br />l <br />I <br />I <br />I <br />L I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />I <br />I <br />—I <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />0 <br />CV <br />N <br />ti <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential <br />6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />�p <br />N 4C14 C � # <br />LQ <br />� r'_ r� at LU _j <br />l9) <br />#1 <br />7LL-' LL 04 LLaa <br />ci <br />� �Y <br />Qc.- <br />2--mmso <br />a <br />W <br />W <br />� 0 r- 0 <br />gsEE_co J0QQ2o <br />L <br />O Q O N <br />M Z U t— <br />W <br />z <br />z <br />a <br />_ M <br />N <br />v 'zLL <br />rl <br />�w <br />_n <br />Uj <br />� <br />O <br />W � <br />Vto <br />Ul <br />c <br />ru <br />0 � <br />_ <br />CX <br />_.►� <br />�0 <br />s�o <br />C1 <br />co <br />w <br />M <br />z <br />� <br />Z <br />a <br />0 <br />_� <br />E <br />N <br />_E � <br />o <br />U <br />oa <br />p <br />U <br />Z <br />N <br />i <br />¢F <br />g o <br />OZ <br />W z <br />0 <br />�? <br />ro <br />N C <br />a o <br />12 <br />o <br />ZLL <br />Z <br />- <br />m <br />> <br />W <br />ZQJ� <br />Z <br />W <br />a <br />NLL <br />� <br />coo <br />i E <br />l <br />0 � <br />U� <br />N <br />> Lo <br />ai <br />L <br />f6 <br />W <br />T <br />cc <br />CV <br />(1) <br />C:) <br />Q_ <br />C m <br />L0 <br />T <br />O Z <br />Ln <br />E <br />N <br />O <br />c N <br />T <br />LD <br />° <br />z <br />C <br />M <br />E <br />E <br />E .. <br />:3 <br />c <br />C <br />E <br />0 _j <br />Q o <br />JOB <br />NO: <br />20-0559 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />