3108 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3108 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:35:27 AM
Creation date
2/25/2025 9:37:47 AM
Metadata
Fields
Template:
Building Plans
Street #
3108
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
22763
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CJ1 <br />CJ3 <br />CJ3 <br />CJ1 <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK <br />SIMPSON STRONG TIE <br />USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />HETA20 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 1Od x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 1Od x 1 1/2"& 8-1 Od <br />H <br />HTT4 <br />3610 <br />3105 <br />5/8" ANCH. /(18) 1Odxl-1/2 <br />HTT4 <br />4215 <br />5/8" ANCH. /(18) 10d x1-1/2 <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 10dxl-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26) 10d x1-1/2 <br />K <br />HD36 * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />-- <br />2 - 5/8" DIA. BOLTS <br />L <br />HD5B * <br />4505 <br />3785 <br />5/8" ANCH. 3/4" STUD BOLTS <br />TDX6 <br />5350 <br />-- <br />2 - 7/8" DIA. BOLTS <br />M <br />HD7B * <br />6645 <br />5650 <br />7/8" ANCH. 3/4" STUD BOLTS <br />TDX10 <br />10140 <br />-- <br />4 - 7/8" DIA. BOLTS <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 - 1 Od x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8 -10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 1/2" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />-- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 1Od x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-1 Od x 1-1/2" <br />S <br />MTS16 <br />990 <br />860 <br />14 - 1Od x 1 1/2" <br />MTW16 <br />1195 <br />1005 <br />14-1 Od x 1-1/2" <br />T <br />MTS20 <br />1 990 <br />860 <br />14 - 1Od x 1 1/2" <br />MTW20 <br />1195 <br />1005 <br />14-1 Od x 1-1/2" <br />U <br />MGT <br />1 3965 <br />3330 <br />22 -1 Od x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -1 Od x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />LGT2 <br />2030 <br />1750 <br />(16)16d SINKERS & (7) <br />1/4" x 2-1/4" TITENS <br />LUGT2 <br />1550 <br />1550 <br />(16)1Od NAILS AND (5) <br />1/4" x 3" WEDGE BOLTS <br />"X" HTS 20 1310 1245 24-1Od x 1 1/2" HTW20 1530 1285 24-1Od x 1 1/2" <br />SP1 555 535 10 - 10d SPT22 735 8 - 10d <br />SP2 1010 1 605 1 12 10d SPT24 1090 12-10d <br />HCP2 1 590 1 555 1 12-1 Od x 1 1/2" HHCP2 680 570 1 (20)1 Od x 1-1/2" <br />* MINIMUM 3" MEMBER <br />** REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 10-17-19 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (B) TRUSS <br />(A) <br />OR 2 PLY <br />;ARRIER <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (6) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (**). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO. PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED, FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS 1 OR CON f LEDGER (A) <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE 5-0"ON A HORIZONTAL PROJECTION, <br />NOTE: SEE SHEET D-1 FOR ROOF FRAMING DETAILS <br />(2) - 12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />REFER TO SG2A/ST3 FOR ADDITIONAL EMBED ANCHORS <br />SEE SHEET D-1 FOR <br />ROOF FRAMING <br />DETAILS <br />FRAMING PLAN - ELEV-131 <br />SCALE: %4'=1'-0" <br />*' <br />.40 <br />Tp <br />+ FI— <br />,a <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />I- �o (0 p�p00 <br />O V N C, <br />Q # <br />COD 0O T (O J <br />N N u, N u LL <br />0 J 'NO -j uj UJ <br />0 � � u; a °- <br />tA � N m w (n = <br />Q > �U- <L Wa W 0 <br />, § <br />Z O In 0) 0-1 <br />@ o m 0 <br />R W .8 O r- (O ¢ Q O <br />I 2 E rn rn a <br />( <br />z CD 0 V <br />Q N M Z 4 0 0 <br />N U F O 22 <br />0 ❑❑❑❑ <br />W <br />_ Ch � <br />z N O <br />� o <br />qNq <br />z ~ Q <br />J (h <br />� N <br />M <br />u, <br />� o <br />v <br />� <br />-J Vi 0 <br />w o <br />c a <br />w <br />E <br />o <br />w. <br />U M <br />w � <br />E <br />O <br />= <br />zl�... <br />P' C.) o <br />co14 <br />Offil <br />Q o <br />o <br />to <br />w <br />M0 <br />¢'sy <br />z <br />z¢ <br />J <br />ca E <br />O- <br />E <br />a <br />z <br /><& <br />Z <br />p a <br />U <br />X O <br />a <br />U U <br />�U <br />O Q <br />C> ro <br />L <br />O <br />W W <br />W <br />MO <br />C/3 C <br />- <br />< ❑ <br />= U <br />m 2 <br />o LL <br />Z <br />J <br />m <br />a `° <br />Q W <br />z <br />(n <br />0 <br />z <br />ao <br />i� <br />U <br />o <br />W <br /><o <br />az <br />=3 <br />O <br />w <br />0 <br />i0 <br />Cfl <br />za <br />a <br />°3 <br />�N <br />0 <br />= <br />` <br />> d' <br />J <br />L <br />D <br />= <br />I\ <br />M <br />�-. <br />C)n <br />Q <br />0 <br />CD <br />a) m co <br />= <br />0 <br />0) <br />■�v J N <br />O <br />r <br />LO <br />T <br />T O N <br />r <br />ai <br />T r <br />C'M <br />o <br />z <br />E 0 N N <br />a)@ <br />(p <br />C <br />n- <br />E a ai <br />0 J Q 0 1 <br />J <br />JOB <br />NO: 20-1133 <br />SCALE : AS NOTED <br />SHEET NO. <br />7 <br />