Laserfiche WebLink
FOLD UP WEATHER <br />RESISTIVE BARRIER & WEATHER RESISTIVE <br />TEMPORARILY SECURE BARRIER i_SLOPE - WINDOW UNIT <br />WEATHER DOOR ROUGH OPENING FLASHING REQUIREMENTS <br />RESISITIVE 0.3 in: 12.0 in <br />BARRIER WOOD FRAME CONSTR. R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall include <br />TAPE EXTERIOR SELF -ADHERED FLASHING 3/4"-1" BEAD OF CONSTR. (O.6 Cm : 30.5 Cm) flashing as described in Section R703.4. A water -resistive barrier is described as a material behind an exterior wall covering that is intended to <br />s SHEATHING BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING resist liquid water that has penetrated behind the exterior covering from further intruding into the exterior wall assembly. An exterior wall covering <br />OVER RIM JOIST AND UP THRESHOLD OF DOOR AND RETURN q p g 9 Y 9 <br />(ASSEMBLEDWINDOW) WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND EXTERIOR is described as a material or assembly of materials applied on the exterior side of exterior walls for the purpose of providing a weather -resistive <br />2 OR EQUAL WEATHER PROOF CAULKING CEMT. FIN. barrier, insulation, or for aesthetics, including but not limited to, veneers, siding, exterior insulation and finish systems, architectural trim and <br />2 <br />O WEATHER SELF -ADHERED FLASHING BUILDING PAPER embellishments such as cornices, soffits, and fascias. <br />RESISITIVE <br />z BARRIER SEAL TOPS OF JOISTS 1 WIRE LATH <br />UNDER DECKING SUBFLOOR R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />SELF -ADHERED FLASHING (SEE DETAIL WP07) ° ° approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches <br />HEAD FLASHING TIE-IN INSTRUXTIONS: (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a <br />1. Cut, fold up & temporarily secure weather resistive RIM JOIST <br />barrier above header to allow for flashing manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />THESE DETAILS ARE GENERIC AND installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under 1 1 R703.7.3 Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based sheathing, shall include a <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />3. Fold weather resistive barrier back over head water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The individual layers shall be <br />BE USED. flashing and seal with tape 2 2 Q installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance with Section R703.4) <br />intended to drain to the water -resistive barrier is directed between the layers. <br />Scale: NTS . SELF -ADHERED FLASHING p pp 9 q 9 <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance equal to or rester than <br />FLANGED WINDOW 1 EXTERIOR DOOR WITH DECK - SECTION A 1 CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER 1 that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially nonwater-absorbing layer or designed <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER drainage space. <br />EXTERIOR SHEATHING MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />EXTERIOR SHEATHING 3/4'A" BEAD OF CONSTR. INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />�I ADHESIVE TO BE APPLIED UNDER FLASHING JAMB & HEAD THROUGH SELF -ADHERED R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity <br />THRESHOLD OF DOOR AND RETURN FLASHING, SEE FLASHING SELF -ADHERED FLASHING or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. All <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WPOt) exterior fenestration products shall be sealed at the juncture with the building wall with a sealant complying with AAMA 800 or ASTM C920 Class <br />REFER TO TECHNICAL SCORED 25 Grade NS or greater for proper joint expansion and contraction, ASTM C1281, AAMA 812, or other approved standard as appropriate for the <br />LETTER ON CHEMICAL ° Q RELEASE PAPER type of sealant. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface <br />COMPATIBILITY pp g p Y g <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING, B of the exterior wall finish. Approved corrosion resistant flashings shall be installed at the following locations: <br />�° (BEFORE FOLDING, SCORE <br />EXTEND MINIMUM 6" RELEASE PAPER TO EXPOSE 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish <br />ADHESIVE AS SHOWN) 9 <br />BOTTOM OF TICALLY FROM or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings shall <br />O THRESHOLD comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following: <br />2 3 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />SECTION -A (SEE DETAIL WP02) manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />SELF -ADHERED FLASHING are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />p 2 sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />z SELF -ADHERED FLASHING 5 1.2. In accordance with the flashing design or method of a registered design professional. <br />NAILING FLANGE O 4 1.3. In accordance with other approved methods. <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />DO NOT FLASH OVER 2 SEAL TOPS OF JOISTS 1 6 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco <br />BOTTOM NAILING UNDER DECKING <br />FLANGE 8 (SEE DETAIL WP07) Z 7 copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING , SELF -ADHERED FLASHING �' • 4. Continuously above all projecting wood trim. <br />HALF ROUND WINDOW EXTERIOR DOOR WITH DECK INSIDE CORNER <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />Ground <br />7. At built-in gutters. <br />SELF-ADHERED FLASHING <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO, FBC <br />R703.2.1 AND FBCR 703.7.3 <br />Detail Instructions <br />Refer to the number marked as O in each detail that corresponds to the <br />numbered items in the list of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROCK- <br />8" CMU <br />4"OR8"CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED - <br />VINYL SHOWER PAN <br />SLOP <br />-- <br />E <br />AM <br />SELF-ADHER <br />Q) <br />1'4' PER PLAN <br />SHOWER SEAT <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />Z <br />W <br />t1 <br />W <br />U <br />W <br />Lu <br />0 <br />U) <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />PLASTER STOP r� <br />CONTINUOUS BACKER <br />ROD & SEALANT <br />A <br />0 <br />0 <br />0 <br />0 <br />a <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />�. 3-1/2" INCH FLANGE <br />THIS, <br />NATU <br />DO Nt <br />DRIP <br />ACCE <br />SOFFIT/CANTILEVER <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) ti <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - - <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />TRUCTURAL FRAMING <br />TRUCTURAL SHEATHING <br />TRIP OF SAF <br />RAINAGE PLANE WRB <br />OND BREAK WRB <br />F LATH <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />.-..0•.O!.!o. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTM C1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />-Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />0 <br />CV <br />0 <br />CV <br />00 <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />° � <br />W <br />F <br />8 <br />m <br />N p r- °D <br />p p p T <br />N r, <br />J <br /># W LL. LL <br />0 <br />9) <br />:"rno <br />9LLN <br />-Jxtww <br />LLLn.d <br />QZ <br />> n r�n <br />ao <br />13 <br />�r&_'E* <br />YLLWoo <br />z <br />OM0o <br />W <br />.2o <br />caC C',W <br />p�0_J <br />Zi <br />2Ec' <br />V N O <br />Q O <br />Z <br />04 <br />�� <br />U ♦- J <br />❑��❑ <br />W <br />N <br />Z S <br />z <br />z <br />J th <br />d. N <br />N <br />- M <br />z 2 <br />0 LL <br />a <br />U <br />a <br />O <br />to <br />V1 <br />w F <br />c i <br />= N <br />o <br />ws <br />r_ <br />U °' <br />w rn <br />E <br />o <br />= <br />z;� <br />U o <br />° <br />CD�ZcoZ <br />U_ <br />ce E <br />O <br />E <br />�° <br />� <br /><� <br />Z® <br />0� <br />U <br /><_ <br />o E <br />U <br />a0 <br />p <br />°Z <br />N <br />�o <br />a <br />rW <br />y� L <br />ra <br />C,OC <br />Q ❑ <br />Z$ Z <br />O Y <br />='m <br />m� <br />o <br />z LL <br />Z <br />J <br />aw <br />W <br />Cn- <br />d <br />S_ <br />�� <br />oM <br />LL <br />< <br />1Z <br />5U <br />a <br />0. <br />0 <br />�°� <br />J <br />aZ <br />w< <br />=3 <br />>° <br />o <br />co <br />a <br />01 <br />0 <br />MMJ <br />O c <br />i <br />a) <br />> cM <br />6 <br />m <br />m <br />L <br />� <br />� <br />T <br />0 <br />0- <br />C m <br />O <br />T°t <br />CV <br />o <br />Li) <br />° v <br />J+ N <br />r <br />L1') <br />7 <br />oo <br />N N <br />LO <br />r <br />r <br />��• <br />E V <br />T f <br />M <br />o <br />E <br />m <br />c r <br />�,; <br />z <br />Z <br />E Ocu <br />E <br />ca <br />U J <br />Q 0 <br />J <br />JOB <br />NO: <br />20-0554 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />W P <br />fib II tl r _, 1 '. 111-,1 1 i 11 1 1 1 11 1 I 1-F <br />