Laserfiche WebLink
3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS r <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />--------------------- <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />18' RIDGE VENT <br />12 <br />5� <br />16'-7" <br />OFFRIDGE VENT -4' OFFRIDGE <br />-------------- <br />EXTENDED <br />OVERHANG TO <br />BE CENTERED <br />ON DOOR <br />12 <br />5� <br />=�- 6-0" <br />---------- <br />--------- T.O.M. <br />T------- HDR <br />------------------- I F.FL. <br />REAR ELEVATION - B1. <br />4' RIDGE VENT <br />12 <br />zz:::�5 <br />------------------------- ---------------------------- — <br />TEXTURED P <br />2'-0" <br />CEMENTITIOUS TEXTURED <br />FINISH ON C.M.U. CEMENTITIOUS <br />(TYP.) FINISH ON C.M.U. <br />(TYP.) <br />RIGHT ELEVATION - B1 <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWNG VALUES, SEE ROOF PLAN`* <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />t <br />uric �ii,� <br />`�`�\e��rrrrr�ti111 <br />SROw <br />a�eN <br />10 <br />Q <br />OF <br />= U <br />C1 <br />J. <br />F L O¢ca8.r <br />�v <br />O F <br />z/f E S S 10 <br />'/f0111jIIilt"00 <br />\\ <br />To the best of the Engineers knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />H <br />Q <br />_E CD <br />� 8 N v <br />(A <br />O O O J <br />.0 CD N W LL Ll. <br />ch <br />A <br />L <br />N <br />.2 C7 'NO --r * W W <br />.)LLB �LLaa <br />M <br />� <br />a W <br />a Y <br />a � Z 0 0 <br />Z <br />�C � mmSo <br />W <br />m o r- <br />2 E°'Or o <br />Z <br />LLW <br />LL <br />m—N ° a o _ <br />NQMZ <br />a <br />U F- 3 <br />_ M `- <br />Z o o <br />� o <br />Z o Q <br />Q <br />M <br />d N <br />rnJ <br />/, <br />t/ <br />M <br />z a <br />0 <br />Q) <br />C9 <br />o � <br />w a <br />M� <br />a <br />ID <br />V) <br />c E <br />U 0° <br />w <br />m E <br />O c� <br />i <br />= � <br />0 <br />S� <br />O <br />C.0co <br />J <br />W <br />Z <br />M <br />zo <br />U_ <br />fl - <br />E <br />�O <br />Zo <br />¢ N <br />Za <br />U <br />Q� <br />°x <br />O E <br />X O <br />O¢ <br />o O <br />U <br />0 d' <br />aZ <br />N <br />z <br />ado <br />< <br />ww <br />W <br />L <br />a (6 <br />- C: <br />❑ <br />z <br />U <br />N O <br />M <br />m O <br />Z W <br />f:, <br />N <br />rO <br />O� <br />¢ W <br />W <br />Q <br />O <br />W <br />U <br />a <br />N w <br />oW <br />J w <br />=� <br />U <br />J <br />0 <br />0 <br /><� <br />0 <br />'o <br />CD <br />zo< ¢ <br />a � <br />oV 3 <br />0 M <br />= <br />co <br />J <br />ui <br />rn <br />m <br />f0 <br />O <br />nL <br />\W <br />QI..L. <br />0 <br />O <br />n <br />CL <br />U <br />l O <br />rw� <br />_ <br />m <br />2 <br />T <br />O ON <br />O <br />0-) <br />J oo <br />1� <br />T� <br />..I.. 0± <br />N N <br />T <br />i— r <br />M <br />o <br />m <br />E O <br />Z <br />@ <br />d <br />E <br />U <br />a r <br />Q 0 <br />c <br />JOB <br />NO: <br />20-0554 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.2 <br />