Laserfiche WebLink
INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS COVER SHEET <br />1 FLOOR PLAN <br />ALL WORK SHALL COMPLY WITH PREVAILING 2 INTERIOR ELEVATIONS <br />CODES FLORIDA BUILUNNG CODE, 3.1 EXTERIOR ELEVATIONS <br />NATIONAL ELECTRIC CODE, <br />3.2 EXTERIOR ELEVATIONS <br />AND THE CITY OF ZEPHYRHILLS <br />OWIINANCEs F1 FOAM DETAILS <br />REVIEW DATE 4 ELECTRICAL PLAN <br />CITY PHIYRHI <br />5 ROOF PLAN <br />PLM EXAMOJER 6 FOUNDATION PLAN MONO <br />7 ROOF FRAMING PLAN <br />8 LINTEL PLAN AND DETAILS <br />SN STRUCTURAL NOTES <br />ABBREVIATIONS SN1 DETAILS <br />AB orAB. Anchor BoltFIX or FXD Fixed PVVDR or PwS3 DETAILSd. Powder Room � DETAILS <br />ABV or Abv. Above FLR or Fir. Floor RA or R/A or R.A. Return Air <br />AC or A/C Air -Conditioner FLR SYS or Fir Sys Floor System RAD or Red. Radius <br />ADJ orADJ. Adjustable FOM or F.O.M. Face Of Masonry RAG or Rag. Retum Air Grill S5 DETAILS <br />AFF orA.F.F. Above Finished Floor FP or F.P. Fireplace REC or Rec. Recessed <br />SS RETROFIT DETAILS <br />AHU or A.H.U. Air Handler Unit FR DR French Door RECEPT Receptacle <br />ALTorALT. Altemate FRT Front REF or Ref. Refrigerator D1 SECTIONS & DETAILS <br />BC Base Cabinet FT or Ft. Foot Feet REINF Reinforcing <br />WP WATERPROOFING DETAILS <br />BF Bifold Door FTG or Ftg. Footing REQD or Req'd. Required <br />BK SH or Bk Sh BookShelf FXD GL Fixed Glass RM or Rm. Room PA1.0 PRODUCT APPROVAL NUMBERS <br />BLK or BLK. Block GALV or Galy. Galvanized RND or Rnd. Round <br />BLW or BLW. Below GC or G.C. General Contractor RO or R.O. Rough Opening PA1.1 PRODUCT APPROVAL NUMBERS <br />BM or Brit. Beam GFI or G.F.I. Ground Fault Interrupter RS, R/S, R/SH or R&S Rod and Shelf <br />PA1.2 PRODUCTAPPROVALNUMBERS <br />BOT or BoL Bottom GT or G.T. Girder Truss SO or SO. Smoke Detector <br />BP or B.P. Bypass (door) GYP BD or Gyp. Bd. Gypsum Board SGD Sliding Glass Door <br />BRG or BRG. Bearing HB Hose Bibb SH or Sh. Shelves <br />C Carpet HDR or Hdr. Header SHT Sheet <br />CAB Cabinet HGT or Hgt. Height SHWR or Shwr. Shower <br />CIR or Cir. Circe HH or H.H. Hand Held (plumbing faucet) SL or S.L. Side Lights ❑ 1 7 ❑ 177 <br />CJ or C/J Control Joint HORIZ Horizontal SPECS or SPECS. Specifications ❑■ ❑ <br />CLG or Clg, Ceiling HS Hard Surface (flooring) SPF or S.P.F. Spruce Pine Fir <br />CMU Concrete Masonry Unit ILO In Lieu Of SO FT or SF or S.F. Square Foot (feet) a � 1=1 <br />rD7 <br />D <br />171 <br />El 177 <br />� <br />COFF or Coff. Coffered or Tray Ceiling INSUL or Insul. Insulation SO or Sq. Square ❑ D <br />COL or Col. Column INT or Int. Interior STO Storage <br />COMP or Comm. Community Kor K.S.Sp o or KMlall Knee SW S.W. Shur Wall <br />or Comp. Compressor KSS or K.Knee Space SYP or S.Y.P. Southern Yellow Pine FD 1:7:1117 1 [17::1 FE71 FE11 17 E] <br />CONN or CONN. Connection LAUN or Laun. Laundry TB Towel Bar <br />CONT or Cont. Continuous LAV or Lev. Lavatory TEMP or Temp. Tempered El 1:71 <br />❑ 17][110 <br />FE71 <br />EACT or C.T. Ceramic Tile LF or L.F. Linear FL THIKN or Thik'n. Thicken <br />D or D. Dryer LL Lintel Length TOB or T.O.B. Top of Block <br />DB Door Bell LT Laundry Tub TOM or T.O.M. Top of Masonry <br />DBL or Dbl. Double MAS or Mas. Masonry TOP or T.O.P. Top of Plate <br />DCF Decorative Cementitious Finish MAX or Max Maximum TP ToNet Paper Holder <br />DEC or Dec. Decorative MC Medicine Cabinet TR Towel Ring <br />DED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TRANS WDW or Trans. Transom Window <br />DIA or Dia. Diameter MGT Management (room) TYP or Typ. Typical <br />DISP or Disp. Disposal MIN or Min Minimum UC or u.a. Under Counter <br />DIST or Dist. Distance MIR or Mir. Mirror UCL Under Cabinet Lighting <br />DMF Decorative Masonry Finish ML or M.L. Microlam UNO or U.N.O. Unless Noted Otherwise <br />DS or D.S. Drawer Stack MONO or Mono Monolithic V or v. Vann (shower or tub/shower) <br />DTL Detail MW or MICRO or Micro. Microwave VB Vanity Base <br />DV or D.V. Dryer Vent NTS or N.T.S. Not to Scale VERT or Vert. Vocal <br />DVP or D.V.P. Diverter Valve (plumbing) OE or O.E. Owner's Entry VL or V.L. Versalam <br />DW or D.W. Dishwasher OPNG or Opn'g. Opening VTR or VTE Vent through Roof / Exterior <br />EA or Ea. Each OPT or Opt. Optional W or w Washer <br />ELEC or Elec. Electrical PC Pull Chain W/ or w/ With <br />ELEV or Elev. Elevation PED or Pod. Pedestal WA or WA age Anchor <br />EQ Equal PH Phone WC or WIC or W.C. Water Closet (toilet) <br />EW or E.W. Each Way PKT or PkL Pock* (Door) WD or Wd Wood <br />EXP or Exp. Expansion Pl. or P.L. Parallam WDW MDR or MOW HDR. Window Header <br />EXT or Ext. Exterior PLF Pounds per linear foot WH or W.H. Water Heater <br />FBC Florida Building Code PLNT SHLF or Pit. Sh. Plant Shelf WIC or W.I.C. Welk -in Closet <br />FDN or Fdn. Foundation PLT HT or Pit. Ht. Plate Height WM or W.M. Wall Mounted (phrrnbig fixture) <br />FG Fiberglass (Shower Pan) PSF Pounds per square foot WP Water Proofing) MEAN F 15 FT. HIGH TYPICAL <br />FIN Finished PT or P.T. Pressure Treated WS Water Softener <br />FOR SINGLE STORY HOMES <br />FIN FLR or FF or Fin. Fir. Finished Floor PW or P.W. Pre -wire WWF Welded Wire Fabric (Mesh) <br />PLAN REVISIONS MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />DATE VERSION DESCRIPTION <br />-15 1.0 NEW BASE PLAN THIS DRAWING AND DESIGN IS VALID <br />0 O- 20 FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />12-8-15 2.0 ADDED VAULT. CLG. CURRENT CODE IS VALID <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />12-28-17 3.0 2017 FBC UPDATES <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />02-21-18 4.0 ADDED GRADE BEAM 150 MPH ENG. Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />08-27-19 4.1 ENG. REVIEW FOR 150-C M P H Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />09-20-19 4.2 ADD 8'-8" E LEV. FOR TREVESTA responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />12-12-19 4.3 E LEV. B EXTEND ENTRY the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />.�� Payments will be made in accordance to the terms of the <br />agreement. <br />Control of Construction Site: <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />1941 construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />/ <br />` <br />P:!' <br />SSE '••^ <br />DAP <br />";yo <br />z <br />s- U <br />IC Q <br />•.. F t0 <br />i����'i// AROFEgs1o� <br />,tad <br />To the best of the Engineers knowledge, infarmmation and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residentlal eth Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />Sog0 ..I J <br />0 <br />N # LL LL <br />J <br />LL a a <br />LL 22 LL <br />c r+ a O <br />ag <br />.Wl <br />Z <br />IL <br />R4— <br />� co a c <br />01 r4 N C C rn <br />113 <br />_ <br />N a M Z U� � <br />(j U ❑❑❑❑ <br />W <br />C9 <br />z <br />z <br />z <br />g <br />ft3 <br />V <br />LU <br />w <br />� <br />0 <br />W <br />_) re <br />N � <br />E <br />so <br />2 <br />0 <br />p <br />g ~ <br />g$ <br />„ <br />w0 <br />(n C <br />C <br />3iY <br />rdig <br />ore <br />gire <br />o <br />W <br />J <br />o <br />RN <br />�I <br />2 Co <br />I..L. <br />^L <br />W <br />/c <br />� <br />•> <br />0 <br />CM <br />l— <br />° <br />m <br />Ccc <br />4� <br />0 <br />r` <br />�•��••�� <br />O 04 <br />p <br />0 <br />�• <br />0 <br />•v <br />= <br />� N <br />n <br />T <br />LO <br />T-' <br />0) <br />M N <br />r <br />E <br />Z <br />M <br />E O <br />; <br />a <br />a <br />O <br />v <br />a: <br />a to <br />C <br />JOB <br />NO: <br />20-0563 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />C S <br />