Laserfiche WebLink
A <br />0 <br />' OWNER'S SUITE <br />8'-0" CLG. <br />CARPET <br />I iv <br />17'-8" <br />G <br />TYP @ 1 STORY <br />rA_'� 1L ] 5'-1 <br />7' (3) 2x4 #2 SPF w/ <br />DTT2Z @ BASE <br />I <br />4'-0" I <br />I <br />I <br />I <br />I <br />C71 <br />= I <br />O � 2:12 VAULTED CLG. <br />io <br />I <br />4'-0" 1 V-7§1 <br />I <br />I R <br />PATIO CAFE <br />VAULT. CLG. <br />000 CARPET <br />C � i <br />00 <br />i <br />i <br />AC PAD <br />i <br />� I <br />H.B. <br />FAMILY RM <br />9'-4" CLG. <br />CARPET <br />i <br />I <br />I <br />I <br />I <br />I <br />6'-10" <br />I <br />I <br />I <br />io <br />6 <br />60"x36" <br />101 <br />MEN <br />0 0' INEN <br />!� 11 ria:1 � �1 ■■■■■1� <br />29' <br />0 <br />5-SH c) <br />6" DP-- <br />R.A. <br />-10" <br />W.I.C. <br />8'-0" CLG. <br />CARPET <br />°n <br />7'-8" <br />2668 <br />HANSON <br />BOX @ 36" <br />A.F.F. <br />DRYER VENT <br />--- THRU ROO - <br />R&S <br />4'-7" 8'-8" (J• <br />rl I H III A,nRft R F III <br />OPT. I <br />REF. <br />--I- <br />NT Y 0. <br />w <br />' =W <br />CO <br />=LAT L ATH <br />16" DEEP <br />BEDROOM 2 <br />8'-0" CLG. <br />CARPET <br />EGRESS <br />O <br />1=7" <br />3" <br />1'.4" <br />H.B. <br />BUILDER TO <br />1----------- <br />N PROVIDE <br />W.H. APPLIANCE <br />I <br />I <br />I <br />I <br />I <br />K TYP @ <br />01 PROTECTION <br />I <br />I <br />I <br />GARAGE <br />WHEN REQUIRED <br />I <br />I <br />I <br />OPENING <br />PER FBC <br />I I <br />I <br />I <br />2 CAR GARAGE <br />8'-0" CLG. <br />20'-0j. <br />I <br />I I <br />I <br />'78 <br />I <br />I � <br />I 8 I I <br />I p I I <br />EDGE OF SLAB 2" <br />BEYOND WALL <br />I I pQ I I <br />T <br />K � <br />S3 <br />I W I I <br />I > I I <br />O <br />I 11 I <br />X I I <br />I l l I <br />I I I I <br />I <br />I l l l <br />I I I <br />I I I <br />IJ �I <br />I I I <br />liliV�l <br />I I I I <br />Ilx - I <br />NOTE: FINISHED I I <br />I I <br />ut Q <br />WALLS TO BE <br />FLUSH. VERIFY IN I I <br />FIELD. I I <br />K <br />CC -D --- ----- <br />1 <br />in <br />S3 (3) 2x4 #2 SPF w/ <br />S3 G.T. <br />DTT2Z @ BASE <br />- <br />F <br />o <br />r <br />� <br />O <br />et <br />My <br />F4 <br />3068 <br />= <br />9'�L ' <br />C <br />ENTRY <br />10--lot, <br />8'-0" CLG. <br />v <br />rn <br />- �1■■■■f•■■ �J111111111111C]IIIIIIIIIIIIC]11111111111,;; <br />5'-4" El <br />i <br />BEDROOM 3 BEDR80M 4 <br />U-10, W1, CARPET CA PET <br />■w��� <br />End <br />01 TYP <br />��■■■� STORY <br />, <br />e <br />FIBERGLASSSURROUND• 11 <br />25-SH <br />EGRESS <br />O <br />19, <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4' X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) -1 314" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />LVL 2.0E Fb=2600 PSI <br />(2) -1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />' VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />*" SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 1 <br />S.H. <br />13 <br />20X38j <br />18jX37j <br />S.H. <br />14 <br />20 X 501 <br />18 J X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 J X 62 } <br />S.H. <br />16 <br />20X72 <br />181X71j <br />S.H. <br />11­12 <br />271/4X26 <br />26X25} <br />S.H. <br />1 H3 <br />271/4 X 38 <br />26 x 37 <br />S.H. <br />1 H4 <br />27 j X 50 1 <br />26 x 50 <br />S.H. <br />11-15 <br />274X63 <br />26X621/2 <br />S.H. <br />11-16 <br />27JX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38Ii <br />36 j X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 1 <br />36 j X 50 <br />S.H. <br />25 <br />37 X 63 <br />36 X 621 /2 <br />S.H. <br />26 <br />37 X 72 <br />36 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 j <br />S.H. <br />33 <br />54 X 381 <br />52 J X 37 i <br />S.H. <br />34 <br />54 X 501 <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 } <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 j <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />ETIE WALLS TOGETHER BY ROTATING <br />BLOCKS EVERY OTHER COURSE <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 518" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 112" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />OA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />O <br />+28.3 / -36.4 <br />�E <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />OG <br />SEE SN SHEET HO SEE SN SHEET <br />'j 40 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />F +34.0 / -44.8 <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 11131" (TRB) <br />1ST FLOOR LIVING AREA 1936 <br />LIVING TOTAL 1936 <br />GARAGE 416 <br />FRONT ENTRY 24 <br />TOTAL AREA 2376 <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />FLOOR PLAN E L E V B 1 ON FRAME 2 x R-1KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION JR-11/R-13 KRAFT FACED <br />SCALE: Y4r=l r-On (GARAGE / LIVING) <br />ryf��'i <br />,`����111111111ttt/ <br />0 <br />W *r <br />c�i <br />d <br />J <br />Q <br />14 <br />.r <br />= U <br />v <br />••• <br />di.t:.. <br />To the best of the Engineers knowledge, information and belief, <br />the structural tural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engines signature and seal. <br />W <br />N <br />�E <br />�8 <br />M N" C# LL LL <br />W <br />LL LL a a <br />Y <br />Z <br />� O <br />Q Cm <br />m <br />W <br />ILW�`r <br />2 m 2 <br />��� <br />rnco ¢ a O <br />_j ppo N <br />NQMZ CS 1= J <br />Wv <br />❑❑❑❑ <br />0 � V <br />z C-4 <br />z� <br />Z� <br />Q <br />a <br />U) <br />NZ <br />0 <br />N <br />LU <br />�N <br />o <br />tJ <br />Q <br />" 0 <br />r <br />o <br />M <br />w� <br />Q <br />C• <br />ao <br />ZQ <br />C <br />a: >_o <br />m <br />�y C <br />�Y <br />Rio <br />m� <br />o <br />gLL <br />>�Z <br />z <br />t)I J <br />u, <br />ow <br />0 <br />�U <br />W <br />29a <br />ii LL <br />CJ <br />U� <br />^ <br />T <br />O <br />C1. <br />[ <br />CD <br />T <br />04 <br />04 <br />11r"- <br />2 00 <br />Cr N <br />T <br />E <br />T <br />M <br />iri <br />o <br />Z <br />Z <br />o O <br />rn <br />v :: <br />c <br />a. <br />U <br />Q p <br />JOB <br />NO: <br />20-0553 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1 <br />