My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3146 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3146 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:36:39 AM
Creation date
2/25/2025 9:38:54 AM
Metadata
Fields
Template:
Building Plans
Street #
3146
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
22515
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />�&GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />t—� <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />� WO EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />HP PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />JE!!3- <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />�� <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />11 #14 copper to lights & outlets <br />NEMA t <br />200 AMP <br />00 #12 copper to 20 amp cMs <br />00 #10-2 copper to WH <br />00 #10-3 copper to Dryer <br />METER <br />MAIN <br />Or <br />0 or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP H.B. <br />GFI DISC. <br />LJCLJIt.JF11 CLJ 1"`CI..Cr 1 F1VLC <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />RI Ill I'11=13 <br />ELECTRICAL PLAN - ELEV-131 <br />SCALE:1/4'=V-0" <br />0 <br />N <br />O <br />N <br />l` <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edifion. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />F <br />Q <br />d 8 g <br />o QQ�,�,�,, 8 <br />A 0 <br />O r N L N LL LL <br />�"W <br />0):gin� <br />U_ LL J d G. <br />a <br />Nth LL fQ 2' <br />t LL a.a LUY <br />Z0 <br />0 <br />� can) <br />� <br />19 <br />W <br />= f � Coop <br />o� <br />E°'O7 �Ca <br />Z <br />IL <br />rn N d O <br />NathZ <br />Z <br />U t- <br />< <br />U ❑1 <br />W <br />c� R <br />N <br />Z <br />Z � <br />z <br />g <br />W''z^ <br />V LLn <br />V <br />Q d <br />0 <br />,., <br />�N <br />= 2 <br />' <br />U m <br />LLt <br />E <br />_. <br />Of <br />soy <br />co <br />w <br />CM <br />M <br />J <br />� <br />o <br />. <br />RLl- <br />Z <br />E <br />�� <br />o <br />g o <br />Q <br />0 <br />H r0 <br />�� <br />a 8 <br />a <br />�w <br />no_ <br />o o <br />Z <br />0 <br />�: i <br />aKa <br />a 2 <br />�$ <br />W Z <br />w <br />o: 2 <br />w2 <br />ro <br />Cf)C <br />=3- v <br />Z <br />OY <br />y 0 <br />m O <br />Oz <br />Z <br />J <br />b <br />Q W <br />> <br />u� <br />a <br />o <br />Z <br />0 <br />V <br />=k <br />W <br />4 <br />'- <br />o <br />y <br />w� <br />w <br />� <br />Mill_o <br />8o <br />2Ci <br />rn <br />m <br />m <br />0 <br />^L, <br />W <br />CD <br />.) <br />M <br />.>_ <br />O <br />W <br />2 <br />c O <br />T <br />i O <br />N <br />T <br />E <br />M <br />T T <br />M <br />o <br />z" <br />C <br />O <br />E <br />" <br />C <br />c°� <br />a o <br />JOB <br />NO : <br />20-0564 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.