My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3172 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3172 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 6:58:27 AM
Creation date
2/25/2025 9:39:12 AM
Metadata
Fields
Template:
Building Plans
Street #
3172
Location
Lytton Hall Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
22502
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m <br />r- <br />N <br />rr <br />S <br />N <br />O <br />0 <br />J <br />i <br />m <br />L0 <br />C'4 <br />c <br />v <br />x <br />N <br />0 <br />J <br />N <br />z <br />rn <br />C <br />a <br />N <br />N <br />E <br />x <br />QC� <br />J <br />c� <br />a <br />U <br />i <br />y <br />I <br />Y <br />0 <br />LZ: <br />N <br />N <br />0 <br />a <br />N <br />N <br />CD <br />_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ <br />1171 <br />\ <br />a <br />' <br />INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS <br />COVER SHEET <br />1 <br />MAIN FLOOR PLAN <br />1.1 <br />UPPER FLOOR PLAN <br />2 <br />INTERIOR ELEVATIONS <br />3.1 <br />EXTERIOR ELEVATIONS <br />3.2 <br />EXTERIOR ELEVATIONS <br />F1 <br />FOAM DETAIL <br />4 <br />MAIN ELECTRICAL PLAN <br />4.1 <br />UPPER ELECTRICAL PLAN <br />5 <br />ROOF PLAN <br />6 <br />FOUNDATION PLAN <br />7 <br />MAIN FRAMING PLAN <br />ABBREVIATIONS <br />7.1 <br />ROOF FRAMING PLAN <br />AB or A.B. Anchor Bolt <br />ABV or Abv. Above <br />AC or AIC Air -Conditioner <br />ADJ or ADJ. Adjustable <br />AFF or A.F.F. Above Finished Floor <br />AHU or A.H.U. Air Handler Unit <br />ALT or ALT. Alternate <br />BC Base Cabinet <br />BF B'Ifold Door <br />BK SH or Bk Sh BpokShelf <br />BLK or BLK. Block <br />BLW or BLW. Below <br />BM or Bm. Beam <br />BOT or Bot Bottom <br />BP or B.P. Bypass (door) <br />BRG or BRG. Bearing <br />C Carpet <br />CAB Cabinet <br />CIR or Cir. Circle <br />CJ or C/J Control Joint <br />CLG or Clg. Ceiling <br />CMU Concrete Masonry Unit <br />COFF or Coff. Coffered or Tray Ceiling <br />COL or Col. Column <br />COMM or Comm. Community <br />COMP or Comp. Compressor <br />CONN or CONN. Connection <br />CONT or Cont. Continuous <br />CT or C.T. Ceramic Tile <br />D or D. Dryer <br />DB Door Bell <br />DBL or Dbl. Double <br />DCF Decorative Cementitrous Finish <br />DEC or Dec. Decorative <br />DED or Ded. Dedicated (outlet) <br />DIA or Dia. Diameter <br />DISP or Disp. Disposal <br />DIST or Dist. Distance <br />DMF Decorative Masonry Finish <br />DS or D.S. Drawer Stack <br />DTL Detail <br />DV or D.V. Dryer Vent <br />DVP or D.V.P. Diverter Valve (plumbing) <br />DW or D.W. Dishwasher <br />EA or Ea. Each <br />ELEC or Elec. Electrical <br />ELEV or Elev. Elevation <br />EQ Equal <br />EW or E.W. Each Way <br />EXP or Exp. Expansion <br />EXT or Ext. Exterior <br />FBC Florida Building Code <br />FDN or Fdn. Foundation <br />FG Fiberglass (Shower Pan) <br />FIN Finished <br />FIN FLR or FF or Fin. Fir. Finished Floor <br />FIX or FXD Fixed <br />FLR or Flr. Floor <br />FLR SYS or Fir Sys Floor System <br />FOM or F.O.M. Face Of Masonry <br />FP or F.P. Fireplace <br />FR DR French Door <br />FRT Front <br />FT or Ft. Foot/ Feet <br />FTG or Ftg. Footing <br />FXD GL Fixed Glass <br />GALV or Galy. Galvanized <br />GC or G.C. General Contractor <br />GFI or G.F.I. Ground Fault Interrupter <br />GT or G.T. Girder Truss <br />GYP BD or Gyp. Bd. Gypsum Board <br />HB Hose Bibb <br />HDR or Hdr. Header <br />HGT or Hgt. Height <br />HH or H.H. Hand Held (plumbing faucet) <br />HORIZ Horizontal <br />HS Hard Surface (flooring) <br />ILO In Lieu Of <br />INSUL or Insul. Insulation <br />INT or Int. Interior <br />KN ALL or K/Wall Kneewall <br />KS or K.S. Knee Space <br />LAUN or Latin. Laundry <br />LAV or Lay. Lavatory <br />LF or L.F. Linear Ft. <br />LL Lintel length <br />LT Laundry Tub <br />MAS or Mas. Masonry <br />MAX or Max Maximum <br />MC Medicine Cabinet <br />MFR or Mfr. Manufacturer <br />MGT Management (room) <br />MIN or Min Minimum <br />MIR or Mir. Mirror <br />MIL or M.L. Microlam <br />MONO or Mono Monolithic <br />MW or MICRO or Micro. Microwave <br />NTS or N.T.S. Not to Scale <br />OE or O.E. Owner's Entry <br />OPNG or Opn'g. Opening <br />OPT or Opt. Optional <br />PC Pull Chain <br />PED or Ped. Pedestal <br />PH Phone <br />PKT or Pkt Pocket (Door) <br />Pl. or P.L. Parallam <br />PLF Pounds per linear foot <br />PLNT SHLF or Pit. Sh. Plant Shelf <br />PLT HT or Pit. Ht Plate Height <br />PSF Pounds per square foot <br />PT or P.T. Pressure Treated <br />PW or P.W. Pre -wire <br />PWDR or Pwd. Powder Room <br />RA or R/A or RA. Return Air <br />RAD or Red. Radius <br />RAG or Rag. Return Air Grill <br />REC or Rec. Recessed <br />RECEPT Receptacle <br />REF or Ref. Refrigerator <br />REINF Reinforcing <br />REQD or Req'd. Required <br />RM or Rm. Room <br />RND or Rnd. Round <br />RO or R.O. Rough Opening <br />RS, R/S, R/SH or R&S Rod and Shelf <br />SD or SD. Smoke Detector <br />SGD Sliding Glass Door <br />SH or Sh. Shelves <br />SHT Sheet <br />SHWR or Shwr. Shower <br />SL or S.L. Side Lights <br />SPECS or SPECS. Specifications <br />SPF or S.P.F. Spruce Pine Fir <br />SO FT or SF or S.F. Square Foot (feet) <br />SO or Sq. Square <br />STO Storage <br />SW or S.W. Shear Wall <br />SYP or S.Y.P. Southern Yellow Pine <br />TB Towel Bar <br />TEMP or Temp. Tempered <br />THIKN or Thik'n. Thicken <br />TOB or T.O.B. Top of Block <br />TOM or T.O.M. Top of Masonry <br />TOP or T.O.P. Top of Plate <br />TP Toilet Paper Holder <br />TR Towel Ring <br />TRANS WDW or Trans. Transom Window <br />TYP or Typ. Typical <br />UC or u.c. Under Counter <br />UCL Under Cabinet Lighting <br />UNO or U.N.O. Unless Noted Otherwise <br />V or v. Valve (shower or tub/shower) <br />VB Vanity Base <br />VERT or Vert. Vertical <br />VL or V.L. Versalam <br />VTR orVTE Vent through Roof / Exterior <br />W or w Washer <br />W/ or w/ With <br />WA or WA. Wedge Anchor <br />WC or WIC or W.C. Water Closet (toilet) <br />WD or Wd Wood <br />WDW HDR or WOW. HDR. Window Header <br />WH or W.H. Water Heater <br />WIC or W.I.C. Walk-in Closet <br />WM or W.M. Wall Mounted (plumbing fixture) <br />WP Water Proof(ing) <br />WS Water Softener <br />WWF Welded Wire Fabric (Mesh) <br />8 <br />LINTEL DETAILS <br />SN <br />STRUCTURAL NOTES <br />SN 1 <br />DETAILS <br />S <br />DETAILS <br />S4 <br />DETAILS <br />S5 <br />DETAILS <br />SIS <br />DETAILS <br />ST <br />STAIR DETAILS <br />SS <br />RETROFIT DETAILS <br />D1 <br />SECTIONS & DETAILS <br />D2 <br />SECTIONS & DETAILS <br />WP <br />WATERPROOFING DETAILS <br />PA1.0 <br />PRODUCT APPROVAL NUMBERS <br />PA1.1 <br />PRODUCT APPROVAL NUMBERS <br />PA1.2 <br />PRODUCT APPROVAL NUMBERS <br />MEAN ROOF 15 FT. HIGH TYPICAL <br />FOR SINGLE STORY HOMES <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />FOR 2 STORY HOMES <br />PLAN <br />REVISIONS <br />DATE VERSION DESCRIPTION <br />THIS DRAWING AND DESIGN IS VALID <br />FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />08-20-15 1.0 NEW BASE PLAN <br />MP�Y WITH gIUNd <br />OUWORK SHALL CC PRE <br />coo�s FLORIDA Tai BUILDING <br />NA''i�ONAL <br />ANDVE I OF ZEPHYRHILLS <br />6ibiA" EB 2020 <br />'Ew DA H„` <br />OF ZE?NER <br />'� �AteN► ECM" <br />12-08-15 2.0 FRAME-WAL REVISIONS <br />CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />12-22-16 3.0 AlB1 ELEV. REVISIONS <br />01-04-18 4.0 2017 FBC UPDATES <br />Notice to Builder & All Subcontractors <br />It is the intent of Designer/Engineer listed in the titleblock of these <br />documents that these documents be accurate, providing Licensed <br />Professionais clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />the commencement of any work. The Designer/Engineer are not <br />responsible for any plan errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />construction. All construction MUST be in accordance to the <br />information found in these documents. Any questions regarding <br />the information found in these plans should be directed to our <br />Office at (407) 880-2333 immediately. No backcharges will be <br />considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />Payments will be made in accordance to the terms of the <br />agreement. <br />02-21-18 5.0 ADDED GRADE BEAM 150 MPH EN . <br />03-29-18 5.1 UPDATED PER CITY COMMENTS <br />08-23-19 5.2 ENG. REVIEW FOR 150—C MPH <br />Control of Construction Site: <br />The Designer/Architect and engineer of record (EOR) have no <br />control over the construction site and shall not be responsible in <br />any manner for control of the construction site including, but not <br />limited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />the indoor air quality, or the effects thereof, for any reason <br />whatsoever. The Designer/Architect and FOR has no duty to <br />protect, without limitation, the residence, construction site, <br />materials, or equipment, from moisture, mold, fungus, fire, theft, <br />vandalism, trespass, or any other peril or condition, at any time, <br />expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />construction and the Designer/Architect and FOR has no duty to <br />take any action or preventive measures to protect such property <br />against any such peril at any time for any reason. <br />2575 <br />i' <br />W/V N <br />P E • <br />— <br />CC •� <br />'4j6 <br />=_ <br />_ <br />Q <br />�O <br />w <br />— <br />. U <br />•• <br />1 <br />_ <br />i <br />F 00 <br />N` <br />O <br />F E S SN <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with dre 2017 <br />Florida Building Code - <br />Residential 8th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />� <br />� <br />oog0 <br />N <br />M �71 <br />J J <br />� cNp �• LL <br />cp AS <br />� <br />tii <br />N rNi S <br />W y <br />L Y <br />Z <br />0OL <br />12rn°' <br />0 a: <br />m0 m°o <br />W <br />� 4 <br />roQQrro <br />iE�0 <br />¢i°a0 <br />Z <br />ILW <br />NQMZ <br />Boa <br />05 <br />Z <br />d6 <br />❑❑❑❑ <br />W <br />� <br />cZ <br />z N <br />z <br />z g <br />a <br />Cl- <br />- <br />t/10 <br />z <br />C1 <br />V)C=1: <br />�V):)l <br />w r- <br />U � <br />L=U: <br />Q <br />co <br />W <br />Z <br />LJL <br />it E <br />a <br />t <br />z0 <br />oa <br />E <br />N <br />O E <br />Z <br />50' <br />X U <br />�< <br />a p <br />Up <br />U <br />UK <br />Z <br />O <br />a Z <br />°do <br />W Z <br />wm0 <br />ro <br />Cl) <br />�gLL <br />�o <br />J <br />� <br />ad <br />s <br />�i <br />W <br />CD <br />0 <br />�L <br />J <br />rn <br />m <br />t0 <br />AL`J <br />■ = <br />l� <br />O <br />T <br />N <br />= r <br />04 <br />^ <br />r <br />E <br />M <br />CV) N <br />Z <br />z <br />c <br />E 0 <br />.— <br />m <br />:3 <br />` <br />� <br />c <br />a <br />c <br />U <br />Q p <br />JOB <br />NO: <br />20-0566 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />C S <br />
The URL can be used to link to this page
Your browser does not support the video tag.