Laserfiche WebLink
i � ti ■�I�y■ y all hll�lVl _ _ _ <br />rn <br />3 <br />3 <br />m <br />r- <br />N <br />A <br />I= <br />c <br />v <br />x <br />N <br />Op <br />J <br />cc <br />O <br />�v <br />i <br />3 <br />m <br />N <br />x <br />N <br />O <br />ii <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station Co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped With an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FIEF <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />�� <br />} <br />' vGFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />I <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />t3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />+FC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />t0, EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />H8 PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />t�T <br />THERMOSTAT <br />ELECTRIC METER <br />Owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERM (NATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />00 #14 copperto lights & outlets <br />NEMA 1 #12 copper t0 20 amp Me <br />200 AMP <br />#10-2 copper to WH <br />#10.3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />FC...._ ...... <br />SYSTEM <br />T _ <br />I I <br />L I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />r—i <br />I I <br />UPPER ELECTRICAL PLAN <br />SCALE: Y4"=1'-0" <br />N <br />0 <br />N <br />ti <br />N <br />Z3 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential Bth Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />in <br />I - <br />a <br />cq' � 8 <br />ti <br />�'7 O N C N LL LL N # m <br />di <br />yarnLu <br />LL U. LL a ry <br />0) <br />a <br />Cl) <br />'6. W rq <br />> clLL O. d Lu <br />L Y <br />Z <br />0 <br />Cw� �m0Q <br />0: <br />`�tO CDoM <br />ECP 0 <br />W <br />z <br />un <br />L <br />O) .� N C d' Q <br />Z 5 zg <br />N Q M U <br />13 <br />z <br />g <br />° � ❑❑❑O <br />W <br />C <br />" <br />z ,���gggSSS <br />Z O � <br />v <br />J eo <br />CD <br />d N <br />N <br />Z c <br />(Dull <br />W <br />�N <br />_U m <br />0 � <br />.l <br />UIt <br />• <br />< a-g <br />soo <br />C"> <br />W <br />J <br />LL <br />0 <br />i o <br />E E <br />O <br />so <br />30 <br />t— <br />QQ <br />X =o <br />U <br />W U <br />Z <br />o E <br />Q O <br />N <br />L <br />as <br />Q i <br />W O <br />�Z <br />w w z <br />C Wj <br />C <br />6 p <br />O <br />o <br />z <br />Z <br />J <br />a ° <br />Z <br />to <br />0_ <br />�LL <br />J� <br />c <br />ID�opW <br />_ <br />N!� <br />� <br />2I4 <br />o <br />U <br />>L <br />J <br />al <br />rn <br />m <br />M <br />L <br />M <br />c� <br />� <br />N <br />,> <br />r <br />_ <br />> <br />M <br />c <br />�.� <br />LID <br />'I\^ <br />0NIT <br />O <br />N <br />N <br />.= <br />= N <br />j O <br />T. <br />LO <br />E <br />T <br />Ch N <br />0 <br />Z <br />E O <br />E <br />E <br />N T <br />m y <br />M <br />c <br />a <br />1J 0 <br />a p <br />JOB <br />NO: <br />20-0566 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />