Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />I`I <br />{.. 1-..1,........... <br />�. . I <br />16GAx1-1\2" LONG 3/4"-1" CROWN 8' I: <br />f <br />MAX-' { I ::: 16GAx1-1/2" LONG 3/4"-1" <br />STAPLES @ 6" O.C. VERT BETWEEN CROWN) STAPLES @ 6" <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />j (NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" a - <br />0 <br />STUB -OUT FOR 1'-0" 0 9 <br />LO <br />GAS METER O o <br />U <br />� F <br />N 0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2) 16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />F.*TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />60 2.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />9"11 <br />FILL CELL <br />STD. 90° HOOK BOND BEAM <br />rn <br />W <br />a STD. 90° <br />CONT. #5 <br />CONT. #5 HOOK <br />BAR <br />BAR <br />OOC <br />#5 CONT. <br />FROM <br />ON <br />TOUHIG HIGHEST <br />------ ------ <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />i <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />I <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />above to bearing below. <br />STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. } Small gap 2" min. <br />2" max 4" <br />• --d max. <br />A <br />/71 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />Leave 1/8" a between to of filler blocking and bottom of to flange. 3) g p p g p2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x : CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING y" GAP @ TOP sides by 6". - Hangers with sides not containing W E g STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION-Birdsmouthcuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />1/16" <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />BLOCKING PANEL, INTERIOR <br />Boise Joist Blocking Vertical load transfer =1900 plf max. along bearing wall <br />Use 3" (10d) nails at 6" o.c. Required on interior walls : for vertical load transfer <br />Load bearing walls � when load bearing - for lateral support when joists <br />/ meet over wall, or wall stacks directly over wall or <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series De th " End Intermediate <br />BC15000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8"j <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />�BC16000s® <br />(BC16500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />! 3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI 60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190SO <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/ (22) <br />NAILS I <br />518"0 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS I <br />R TRUSS <br />OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />10 <br />for each lapped joist. <br />blocking panel *Non -stacking walls <br />(quash block) 10dnails SECTION @INT. BRG. WALL require additional consideration.- <br />2x4 minimum <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />" `" MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />6"" A %" ROUND HOLE MAY 6"" 6"" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y2" <br />THE WEB, PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y" <br />.,, z • aw <br />E `��ec <br />t-w!= <br />'� <br />�'� <br />ii' <br />'ya k� <br />d <br />h�ik <br />p'k7' ka�".. <br />S� � <br />_ ".i�' <br />ri ;. <br />.,_ <br />Aw 16" idst <br />Span 00 ----16 <br />8 <br />1"-0"" <br />VA" <br />T-T <br />T-2" <br />1�-3' <br />T-3"' <br />V-T" <br />1'-11": <br />`24" <br />2'-9' <br />3" 2" <br />3, T° <br />12 <br />1"4"" <br />1"_1," <br />1" c' <br />1" 2"" <br />1,_3"" <br />T-9' <br />2-4'" <br />2-11 " <br />3, T <br />4, 2' <br />4-9' <br />6-4' <br />1"-01, <br />T-1," <br />1, 2' <br />1, 2," <br />1' T' <br />2'-5'° <br />3'-T <br />3'-10" <br />4'-9,° <br />F-T <br />6,-". <br />7 Z" <br />2Cl <br />1, "" <br />1"-T' <br />1 2'" <br />1" 2"" <br />2'-9- <br />3' 0'. <br />4,- - <br />4'-16,. <br />5'-11"" <br />6'-11'° <br />7'-11" <br />S'-11,. <br />24 <br />T-a' <br />T-1," <br />1 2"" <br />V-3,. <br />2,,-"" <br />3' T <br />4'-9"' <br />6-10," <br />7 T" <br />9-4' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Jc <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />ea . <br />$ a <br />00 <br />FINISH GRADE <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. — <br />Install tight to top flange. SLEEVE THRU STEM a <br />°.. <br />SEE PLAN FOR °• a . • • ° <br />FOUNDATION INFO <br /><a. <br />STEM FOUNDATION <br />y \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />i <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />� 0.6 X Joist <br />`depth <br />I <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />q <br />REINF. SEE PLAN <br />L A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />JOA <br />LOCATION OF <br />SECOND H10A <br />SIMPSON ° (WHEN <br />w/ (18) 10d REQUIRED) <br />NAILS <br />UPLIFT= 1 <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />I-Ili=III=11 <br />ill �lllllll�4. <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />° 4 4° 11 I_I <br />_IiI <br />i — SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4' 0"—\ <br />CENTERED @ PIPE <br />PENETRATION <br />�PLUMPVC OR SCH40 SLEEVE <br />BING <br />i— LINE <br />Z • a <br />°. <br />SEE FND. PLN, <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />°Q <br />a <br />n '4 <br />V C <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />e+� <br />N <br />CV C <br />�C-1� <br />ca ,e <br />Vf -ryN <br />�E <br />0 <br />.:mC9{IFt� <br />•cp <br />s N <br />�Fs9 �, 0e�• <br />�g9O '3 t t - <br />y <br />yy <br />pp <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />11- O E N <br />q 4 O M 8 co <br />o o> 4 <br />V N , LL <br />N a (nr �LL Lu f11 <br />V) co v- w a o- <br />Q Y <br />J_J LL a <br />te z <br />—� <br />Z O o <br />v_ o <br />_ t m o <br />rr <br />r�o o <br />7'N CVO m Q <br />W <br />W 0 0 0 J Z <br />d o w <br />Z <br />(h Z 6 � <br />LL <br />N F- <br />z <br />do ❑❑❑ <br />W <br />CD <br />N M <br />o g <br />N <br />z o � <br />J <br />13 <br />N <br />M <br />Ln z aCz <br />C9 `o <br />L1 LL <br />Tf <br />�J W <br />d m <br />U <br />O <br />w o <br />v / Ly N <br />Ul) <br />r� <br />r— E <br />M.., <br />t <br />i_. U o N <br />• <br />¢ N 0 <br />� <br />w <br />M <br />M <br />J <br />`� � <br />� <br />Z <br />2 <br />4 <br />� <br />� <br />E E <br />zo <br />Zo <br />ca O <br />wo <br />Da <br />I- (d <br />a <br />o< <br />�o <br />o< <br />E <br />h <br />g <br />t- <br />C <br />¢❑ <br />Y <br />m� <br />0, <br />7 <br />zz <br />CIO <br />A <br />0< <br />w <br />z <br />z <br />to w <br />W <br />2z <br />M3 <br />Mill <br />4- M <br />d F <br />�U <br />zId <br />3 <br />.� p <br />J <br />>M <br />O <br />ai <br />rn <br />ro <br />CID (0 <br />T <br />� r <br />� <br />Cr >, <br />r <br />Q CL <br />(n � cc <br />N <br />Co <br />—_ <br />LO <br />N <br />O <br />0 <br />M O <br />Ln <br />N <br />Q CY) N <br />'_ <br />at <br />T <br />M CM <br />o <br />N i6 LO <br />z <br />Z <br />E <br />m <br />rz <br />a <br />E <br />0 � Q o <br />C: <br />JOB <br />NO : 23-06108 <br />SCALE : AS NOTED <br />SHEET NO. <br />SIN 1 <br />