Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />11 <br />#14 to lights & outlets <br />NEMA 1 <br />DO <br />#12 to appliances and GFI <br />150 AMP/ <br />200 AMP <br />#10to WH <br />#8 to Range <br />#6 to HVAC <br />METER <br />MO50=2/0 <br />r2OO=4/0 <br />in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF 1.5" VTR III 3" VTR <br />Bathroom 39" AFF III -ill <br />\ <br />I <br />Laundry Room 36" AFF I <br />Exterior Waterproof 12" AFF I I <br />I <br />Garage - general purpose 44" AFF ^ \ I <br />Range 2" AFF I \ I <br />2. All trim plates and devices to be ganged, where possible. i <br />3. Electrical switches to be at 42" centerline above finished floor. I I \ <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National I <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FITT- <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />?4. FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I--O WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />P.C. <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />,V11 EXHAUST FAN/LIGHT COMBINATION <br />�D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />[]B PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TV TELEVISION (OPTIONAL) <br />TV 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />_mil DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />C� J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED ' <br />RECEPTACLE FOR <br />MICROWAVE RANG <br />HOOD PER SPECS <br />1113" VTR <br />U <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />SWITCH FOR <br />DISPOSAL <br />X ULIC <br />I GFI\ <br />,r CV <br />I <br />0 <br />FGFIII <br />DWI <br />L--� \ <br />LL <br />:,KITCHEN' / <br />SPEC 3 & 4 KITCHEN <br />A/C PAD <br />DISC. WIP <br />GFI <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE - <br />HOOD PER SPECS <br />GII•I <br />_ I <br />I <br />TO LIGHT <br />AND <br />SWITCH <br />ABOVE <br />NOOK <br />LANAI <br />ROUGH -IN OR t J <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE' <br />\ <br />GFI <br />SWITCH FOR <br />1 <br />DISPOSAL <br />FAMILY <br />I <br />PENDANT <br />I <br />ROUGH -IN FOR <br />D` <br />luc <br />AS PER <br />OPT. CLG. FAN/ <br />I GFI <br />'_ <br />I <br />SPECS <br />LIGHT PRE -WIRE I <br />o <br />� <br />� <br />I( <br />G / <br />GFI 1 <br />ITCHEN\ <br />w <br />REF <br />LAU <br />GFI <br />42" <br />CH <br />\ DINING <br />t <br />PENDANT AS <br />PER SPECS <br />' <br />1 <br />PWDR <br />1'I'I'I'IT I <br />GFI @ 44" / — <br />GFI @ 44" <br />A.F.F. <br />A.F.F, <br />)Af.H. <br />\ <br />1 <br />I <br />\ <br />I <br />— — <br />z <br />— '^ — — — — — — — — — — — — — — — <br />GARAGE <br />— — — — — — — — — — — <br />Z <br />O <br />J v"_ <br />�IGARAGE <br />_— <br />ASLL <br />I <br />L--`—�--h <br />=JIGHT <br />PER SPECS <br />o <br />/ 9 <br />w <br />>w <br />GARAGE <br />--------------��d�--------------- <br />GFI <br />I <br />I <br />IRRIGATION <br />I <br />I <br />GFI @ 44" <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />A.F.F. <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />FOYER <br />M� <br />hDBENTRYGFI & GFI TO <br />-------- I BE ALIGNED <br />VERTICALLY <br />I <br />/ <br />/ <br />/ <br />COACH LIGHTS "COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS / '� PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I <br />I I I <br />I I I <br />I I <br />I I I <br />I <br />I-----------I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I t <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L-------------------------------------- <br />SECOND FLOOR ELECTRICAL PLAN <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-A <br />ELEV-A <br />ZV <br />c� <br />d -o <br />J <br />9 W <br />C. s <br />cs a. <br />�- <br />.� R O L <br />w O <br />CZ N � <br />� � as <br />t= <br />ffi• <br />� <br />r i <br />W� <br />M <br />O <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />u... �' <br />Q <br />o E S N <br />O co 3 N <br />v <br />® <br />� ° ft <br />J <br />OD 510) L L <br />N <br />I.L W <br />3 a- a <br />'e Q <br />�Mv w <br />c L a rn Z <br />J LL (n <br />O <br />= <br />r Mo o <br />.0 <br />o <br />_ <br />W <br />on') d m <br />cn J - w <br />ILW <br />Ci <br />N <br />O U ❑❑❑ <br />W <br />U <br />065 0 <br />Z N <br />z o � <br />Q <br />QCl- <br />J <br />t- <br />_ <br />z LL <br />Q) <br />�- <br />UI <br />W <br />U <br />0 <br />V) <br />�V) <br />„-, g <br />ws <br />U <br />W <br />J <br />r— — E <br />3 <br />mIW <br />I <br />e <br />= � ai <br />z. <br />U N <br />Cl) <br />�® <br />P <br />o <br />M <br />M <br />J <br />� Q <br />Z <br />w <br />Z <br />Q <br />LL <br />ce E <br />z o <br />0 <br />z o <br />4 ry <br />o <br />U <br />0 <br />wz <br />zo <br />oa <br />ca <br />ro <br />�� <br />00 <br />c E <br />4 <br />ao <br />0 <br />0 <br />-Z <br />m <br />wo <br />�H <br />C <br />¢o <br />�m°� <br />pi <br />mo <br />Z4- <br />m <br />-0'< <br />w <br />C 3 <br />a< <br />z <br />go <br />W <br /><0 <br />aZ <br />m <br />o� <br />z <br />�¢ <br />�3 <br />= F <br />J <br />o <br />J <br />wa <br />;o <br />M <br />d- <br />ol`i <br />d F <br />o 3 <br />�C) <br />> CM <br />J <br />0 <br />rn <br />m <br />ca <br />N <br />N <br />ICU ( <br />T <br />� r <br />� <br />Q <br />2 <br />U)0 <br />N <br />m <br />_ <br />LO <br />h <br />N <br />0) N <br />LO <br />N <br />�C <br />c r <br />r <br />M C\ <br />o <br />CU <br />N <br />U) �n <br />Z <br />Z <br />E T— <br />CU <br />aci <br />0 <br />¢ o <br />a) <br />JOB <br />NO: <br />23-06108 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />