My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36500 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36500 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:48:22 AM
Creation date
2/25/2025 9:40:21 AM
Metadata
Fields
Template:
Building Plans
Street #
36500
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
5925
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A: ' <br />ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS <br />ABV -ABOVE MLDG -MOULDING THE FOLLOWING TECHNICAL CODES SHALL APPLY: VERSION DESCRIPTION OF CHANGES SHT NO: TITLE N <br />AFF -ABOVE FINISH FLOOR MNT - MOUNT OR MOUNTING 1.0 PLAN REVISIONS CS COVER SHEET <br />AHU - AIR HANDLER UNIT MO - MASONRY OPENING Al FOUNDATION PLAN <br />A/C - AIR CONDITIONING MUNT - MUNTINS 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, 2.0 TRUSS CONNECTOR REVISION A2 FLOOR PLAN a <br />ALUM - ALUMINUM # -NUMBER ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 A3 ROOF FRAMING PLAN <br />AT - ALUMINUM THRESHOLD OC - ON CENTER 3.0 FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATE <br />A4 ROOF PLAN 'n <br />AB - ANCHOR BOLT OGD - OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 4.0 GAS FIXTURES ADDED' LO <br />" O <br />AVG -AVERAGE OPNG - OPENING 1. TANK TYPE WATER CLOSET VOLUME <br />A5 EXTERIOR ELEVATIONS , N' • • ��� ; <br />1.6 GALLONS A6 FLOOR ELECTRICAL PLAN <br />SNO STRUCTURAL NOTES ;; '4 o Q <br />BFE -BASE FLOOD ELEVATION OPP -OPPOSITE �?,' <br />BM -BEAM OPT -OPTIONAL <br />BLK -BLOCK OH - OVER HANG 2. WATER -FLOW RATE. SN1 STRUCTURAL NOTES 0 <br />BLDG - BUILDING OH CABS- OVERHEAD CABS S3M FOUNDATION DETAILS , a w <br />BRD -BOARD PNT -PAINT FINISH S4 FRAME WALL DETAILS <br />PUBLIC FACILITIES LAV 0.5 G.P.M. ' g <br />BRG -BEARING PTD -PAINTED PRIVATE FACILITIES LAV 2.2 G.P.M. .� c� <br />S5 ROOF FRAMING DETAILS c' O <br />BTM -BOTTOM PED -PEDESTAL <br />SHOWER HEADS 2.5 G.P.M. o <br />SS RETRO FIT DETAILS ' a ,y 0 <br />; , • lY <br />BUC - BUILT UP COLUMN PERF -PERFORATED S11 PRECAST DETAILS,..` <br />CAB - CABINET PLT -PLATE 3. ALL PLUMBING WATER LINES • <br />CD - CONSTRUCTION DOCUMENTS PLYWD - PLYWOOD TO BE CPVC S12 PRECAST DETAILS w <br />CLG - CEILING PKT -POCKET PA1.0 PRODUCT APPROVAL p <br />CLG HT - CEILING HEIGHT LB -POUND VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO PA1.1 PRODUCT APPROVAL Q <br />CEMT - CEMENTITIOUS PSF - POUNDS PER SQUARE FOOT JOBSITE CONDITIONS PA1.2 PRODUCT APPROVAL <br />CL - CENTERLINE PSI - POUNDS PER SQUARE PA1.3 PRODUCT APPROVAL <br />COL - COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA1.4 PRODUCT APPROVAL <br />CONC -CONCRETE PB - PUSH BUTTON CODE PA1.5 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE Q PORCHES AND BALCONIES SH 1.0 HURRICANE SHUTTERS <br />CONT - CONTINUOUS OR CONTINUES REINF - REINFORCING CHAP. 3 SH 1.1 HURRICANE SHUTTERS .> ' o u <br />CTR -CENTER REQD - REQUIRED SH 1.2 HURRICANE SHUTTERS m M 0 m <br />CJ -CONTROL JOINT R/A - RETURN AIR Q HANDRAILS - CHAP. 3 SH 1.3 HURRICANE SHUTTERS D i3 2 u it <br />DP - DEEP OR DEPTH RO - ROUGH OPENING SH 1.4 HURRICANE SHUTTERS V -0-0- s M <br />DTL - DETAIL RS - ROUGH SAWN Q GU,�RDRAILS - CHAP. 3 SH1.5 HURRICANE SHUTTERS E u <br />DIA -DIAMETER SC -SOLID CORE WP1.0 WATERPROOFING DETAILS p w 8 o Q <br />DIM - DIMENSION SCP -SCUPPER Q STAIRS - CHAP. 3 U t7 <br />DISCON - DISCONNECT SCRN -SCREEN <br />to w s1" <br />DW - DISHWASHER SIM - SIMILAR , �Y i ao M v, <br />DR -DOOR SHLVS -SHELVES Q CHIMNEY & FIREPLACE0 CO <br />DBL - DOUBLE S/R - SHELF & ROD CHAP. 10 <br />DWG - DRAWING SH - SINGLE HUNG WINDOW s7 a <br />EA -EACH SGD - SLIDING GLASS DOOR Q EGRESS WINDOWS J� <br />ELEC - ELECTRICAL SPECS - SPECIFICATIONS CHAP. 3 <br />ELEV - ELEVATOR SQ FT - SQUARE FEET <br />EQ -EQUAL SQ IN - SQUARE INCH 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS STATED �IA, <br />EQUP - EQUIPMENT STD -STANDARD BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS AND O.H. <br />EXP JT - EXPANSION JOINT STL -STEEL GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE ITEMS. THE canEXT - EXTERIOR STRUCT -STRUCTURAL MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR SITE <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FG - FIXED GLASS TOC - TOP OF CONCRETE AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />FD - FLOOR DRAIN TOM - TOP OF MASONRY OVERHEAD GARAGE DOORS, AND ROOFING. <br />FE - FIRE EXTINGUISHER TOP - TOP OF PLATE <br />FLR - FLOOR TP - TOILET PAPER HOLDER <br />FLOUR -FLUORESCENT TYP - TYPICAL 6. ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED ALL <br />FTG - FOOTING LINO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS ❑ w w ° <br />FR DR - FRENCH DOOR VAC -VACUUM LU z <br />GALV - GALVANIZED VAL -VALANCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF FLR � (D Ll.l J ° 3 LL U ° J O <br />TO BE TEMPERED GLASS. (SECTION R308) Q ° o o it o o m ° Z <br />GA -GAUGE VERT -VERTICAL Q— a x Z o Z o° a a <br />GB -GRABBAR VIF -VERIFY IN FIELD ~O ��av�wwwcn��Q°12 <br />GFI / GFCI- GROUND FAULT CIRCUIT INTERRUPTOR VTR - VENT THROUGH ROOF DIMENSIONING: Q Z 0 a¢ ° w ¢ 0 z w z o w o o a <br />GWB -GYPSUM WALL BOARD WC -WATER CLOSET a o c ° ~ o ° ¢ a a <br />GYPBRD - GYPSUM BOARD WH - WATER HEATER A. DIMENSIONS INDICATED ARE TO: <br />HD - HEAD WL - WIND LOAD A.1. CMU WALL: OUTSIDE FACE OF WALL <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING WP - WEATHERPROOF A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />HT - HEIGHT WWM - WELDED WIRE MESH CORE -STUD <br />HB - HOSE BIB W - WIDE OR WIDTH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. O <br />HC -HANDICAP WDW -WINDOW FURRING\ <br />O <br />INSUL - INSULATION W/ - WITH A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD Z CV <br />INT - INTERIOR WD -WOOD A.4. WINDOW OPENINGS: O LV <br />LVL -LAMINATED VENEER LUMBER I_A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING <br />LT - LAUNDRY TUB (n D ti <br />LGT - LIGHT A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING � � O <br />MAX - MAXIMUM A.5. DOOR OPENINGS: (p O <br />MATL - MATERIAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING 0 i. M O <br />MFR -MANUFACTURER A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING Q (n M � <br />MECH - MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED a- <br />MTL - METAL FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR ti" <br />MC - MEDICINE CABINET FRAME Q W Q L~ <br />MIN - MINIMUM A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER I— W a M <br />OF DOOR X 0- 'r'- <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES - AS INDICATED ON PLANS OR FINISH Q >- Q 00 <br />SURFACE TO FINISH SURFACE Z U H <br />SYMBOL LEGEND . A.6.1. EXAMPLE: 3'-0" CLEAR INSIDE FINISH FOR ADA TRANSFER SHOWER LU z <br />B. ALIGNMENT OF WALLS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE AND LLJ �O <br />PLUMB. J A = STAIR CALL OUT HEIGHT OF SHEET NUMBER O <br />—STEP DOWN C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: (p <br />1 INT ELEV NUMBER C.1. CODE MINIMUM - MAXIMUM DIMENSIONS AND CLEARANCES It <br />FOOTING CALL OUT - STEP DOWN ARROW SHOWS C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS AC SEE FOOTING CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR <br />SCHEDULE <br />ARROW SHOWS INTERIOR ELEVATION CA. FRAMED WALLS INTERIOR <br />= KEYNOTE CALL OUT DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWS <br />1 D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />ELEV NUMBER UNLESS OTHERWISE NOTED <br />A9 ARROW SHOWS PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE <br />CD= OUT - SEE LENTEL EXTERIOR 1 OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />SCHEDULE ELEVATION MARKER Al SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE <br />1 SHEET NUMBER STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />---ELEV NUMBER G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, <br />LLEDGER CALL OUT - EDGER SCHEDULE SEE 4 A15 SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />LOCATION OF CUT COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE <br />r----ARROW SHOWS DRAWINGS. <br />3 DIRECTION OF VIEW <br />MULTI VIEW INTERIOR SECTION <br />ELEVATION MARKER MARKER O 0 0 <br />N N <br />O O <br />RECEIVEL M N N N <br />� M � <br />O 4- N <br />o0011ll <br />MAR 2 9 2023 0 z <br />U) <br />NLO;-N�iiil <br />LO d. <br />MAR 2 5 2023 1 <br />Z <br />ZZ <br />aw <br />O �--+LEM= N NA Mo W W 00 <br />V ()(-)U)i= ow> <br />Virtual Review Assist. Inc. o <br />Plans Review completed and approved Z w a- <br />for compliance with the 2020 FBC 7th Edition r� Q Q a <br />L E N N A R TAM PA DIVISION by Debra Anne Klahr PX2300 dam' = m W <br />4600 W CYPRESS ST SUITE 200 T' z°cn <br />' NOTICE TO BUILDER & ALL SUBCONTRACTORS w a 2g2 <br />TAMPA, FL 33607 IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE 0 O gwu- <br />a <br />Z U z <br />813.574.5700 BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING Z T< <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT V J <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL O <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE O IZ <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE MM <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OIAISSIONS,OR W <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE Q <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL z w C S CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE W rr. o <br />INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE NO <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK > o LAST PLOT DATE <br />1450 CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE + December 14, 2022 <br />DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND <br />APPROVAL BY THE DESIGN PROFESSIONAL. z 0 <br />J COVER SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.