My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36500 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36500 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:48:22 AM
Creation date
2/25/2025 9:40:21 AM
Metadata
Fields
Template:
Building Plans
Street #
36500
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
5925
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHINGLE RC <br />1 1 /4" THK x <br />STUCCO BA <br />5/8" STUCC, <br />OVER CMU <br />(DfRRON TS ELEVATION B <br />1 /4 - 1 -011 <br />REAR ELEVATION B <br />1 /411 = 1'-0" <br />RIGHT ELEVATION B <br />1 /4" = 1'-0" <br />I <br />7 <br />I A5 <br />I <br />I <br />I <br />I <br />I <br />ti <br />LEFT ELEVATION B <br />1 /4" = 1'-011 <br />.EV AT 8'-0" <br />T.O.M. <br />:V AT 0'-0" <br />FLOOR FF <br />VGLE ROOF <br />ELEV AT 8'-0" <br />T.O.M. <br />5/8" STUCCO <br />OVER CMU <br />00 <br />io <br />1518" STUCCO <br />OVER CMU <br />y <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />12 <br />5 <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOFTRUSS <br />MTL DRIP EDGE <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />OVERHANG DETAIL <br />J ATA11 = I - <br />ROOF FINISH PER <br />ELEVATION <br />ROOF SHEATHING <br />roc <br />MANUFACTURED <br />ROOFTRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />PER ELEVATION <br />ALUMINUM <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />OVERHANG DETAIL <br />6 <br />5/8" STUCCO <br />OVER CMU <br />y <br />7-ICMU COLUMN DETAIL <br />ELEV AT 8'-0" Adk <br />T.O.M. <br />2'-0" <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />ELEV AT 8'-0" <br />T.O.M. <br />_ ELEV AT 0'-0" <br />1ST FLOOR FF <br />NOTE: <br />FOAM TO BE USED ONLY WHEN <br />REQUIRED BY COMMUNITY <br />SPECS. IF NOT, DETAIL TO BE <br />BUILT W/ STUCCO <br />e� <br />, jEL Zrr� ION DETAILS <br />5/8" STUCCO <br />FINISH ---- <br />2" L VARIES <br />CV <br />N <br />ASSUMED GRADE <br />9 ELEVATION DETAIL <br />MAR 2 5 2023 <br />Virtual Review Assist. Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX23GO <br />1 1/4" THICK <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />* EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />N <br />N <br />0 <br />v <br />T <br /><: <br />Go <br />Ln <br />' 0 W <br />' n ' O <br />W <br />❑ <br />z <br />a <br />N <br />OL0F E <br />� <br />W L = �0 N U <br />❑ M F m <br />+�— <br />0 <br />} O Zjm u <br />V - co,8M <br />.O 2 <br />O <br />0 LL 8 R Q <br />S <br />� <br />N ^` <br />O^ <br />Q N C <br />i w 0o <br />E F <br />7W <br />V, <br />W W <br />W <br />Ouj C W 0H <br />H~ z -1 o_f ~z� <br />(D <br />Q <br />L) <br />�02 �¢O¢�¢tLU0��0 <br />F- <br />OWW 0 OROOMOZ¢¢ <br />_30a�z' aZZLL0W0Wa <br />Z <br />QLL �wO���_�Wo <br />Qua <br />OW o 0 o Z <br />F ¢ LL <br />O <br />Z W <br />o� <br />U) <br />M O <br />Q � M � <br />(A <br />� <br />11') <br />H 0 cM <br />Zoo <br />V <br />W <br />W <br />JQ <br />O <br />ct" <br />O <br />o <br />N <br />0 <br />N <br />0 <br />N <br />C <br />°' <br />O <br />z <br />o <br />� <br />o <br />0 <br />N <br />W <br />L? <br />LO <br />O <br />CV <br />M <br />I <br />I <br />i <br />d- <br />zZ <br />az <br />w <br />O <br />� <br />W <br />❑00 <br />O <br />U <br />L)V <br />LO <br />O <br />Off❑ <br />Z <br />(L <br />Q <br />C) <br />_ <br />W=a <br />v <br />~~O <br />H <br />1--I <br />z 0-,0 <br />= <br />■ <br />W <br />>- <br />Q F- <br />0-) <br />O <br />ZWO <br />0 <br />Z <br />0a <br />It <br />ZLL <br />• <br />Z <br />0 <br />U0 <br />W <br />z <br />a <br />z <br />z <br />w <br />W <br />04 <br />0 <br />Q <br />o <br />O <br />LAST PLOT DATE <br />• <br />December 14, 2022 <br />Z <br />O <br />EXTERIOR <br />'J <br />ELEVATIONS B <br />
The URL can be used to link to this page
Your browser does not support the video tag.