My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36547 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36547 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 11:58:20 AM
Creation date
2/25/2025 9:40:33 AM
Metadata
Fields
Template:
Building Plans
Street #
36547
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
5568
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I'!R Y�1� 1�t'll' � f t�h4�ll�l�ll�! I[�■■I■��iK <br />4 <br />DISCONNECT <br />a <br />FAMILY <br />co ROOM / 0 <br />6'-7" \\ <br />G <br />KITCHEN t �o FIEF <br />\ / 4i <br />GFI AT <br />30" A.F.F. <br />db <br />FOR <br />HOOD I <br />" o <br />TO I / <br />� ISP <br />J c B i o ® \4 C' <br />O <br />DINING \ ' ---/ <br />i <br />ROOM J GF AT <br />30" A.F.FJ DW v <br />\ 3'-8" 3'-0" P 4' 0" <br />PWDR <br />BATH <br />TO 2ND <br />FLR ELEC <br />f 2' 3" <br />A <br />T <br />i <br />' LINE OF <br />FLOOR <br />I ABOVE <br />FOYER <br />I <br />OWNER <br />SUITE <br />...sell � �1■ <br />6'-5" <br />W.I.C. 1 �, <br />l � v <br />/ LIGHT AND <br />_ SWITCH IN 0 <br />FT —k.9 ATTIC <br />ELEC <br />IPANEL <br />110V CLG <br />q ! MNT. <br />N ^✓ OUTLET <br />GFI <br />GFI i <br />I <br />i <br />I ' <br />i <br />i <br />I � i <br />I <br />I Q <br />I <br />I <br />I <br />i <br />FIRST FLOOR ELECTRICAL PLAN B <br />1 /411 = 1 1-011 — <br />I <br />I <br />I <br />I <br />METER <br />LINE OF ROOF <br />nr, �,a <br />SECOND FLOOR ELECTRICAL PLAN B <br />1 /4" = 1 1 <br />-0" <br />ELECTRICAL NOTES. <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />OCT 2 8 2022 <br />VV\7 <br />Virtual Review Assist. Inc. <br />Plans Review completed and approved <br />for compliance with the 2029 F8C 7th fditiou <br />by Debra Ague Klahr P12300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ■ <br />4 1/2" <br />DOORJAMB DUPLEX Qo <br />OUTLET co <br />TRIM--- <br />BASE--- <br />0 <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />e <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />i 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-O PUSH BUTTON FOR GARAGE DOOR OPENER <br />—o DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />{ CLG MNT PREWIRE - FIXTURE BY OWNER <br />{- SURFACE MNT FIXTURE <br />-{ WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />6� 50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />Q SMOKE DETECTOR <br />CU-182 UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />— U-36 = UNDER CABINET 36" <br />S-36 SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:R 24" VANITY LIGHTING <br />F_mF 36 :ruP 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />IM CHIMES (DELETE W/ INTERCOM) <br />]� MASTER STATION <br />-M&3 ELEC PANEL <br />® VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />ED A/C REGISTER <br />® THERMOSTAT <br />ED SECURITY PAD <br />LECTRICAL SPECIFICATION NOTES: <br />LECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />PECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />IXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />N <br />N <br />0 <br />N <br />�t o <br />O 00 <br />-_ <br />j <br />A <br />00 <br />ma`s <br />4# <br />° <br />LL <br />Q <br />° AR0015S') <br />z <br />w <br />w <br />z <br />Q <br />W <br />`0 o <br />.7 M N <br />M�i <br />U <br />4-- <br />tJI <br />.4. N <br />V' ao <br />t <br />u a <br />L <br />E 2 <br />U_ g <br />_o o <br />�N <br />N <br />U lu QN <br />o E� <br />70 <br />i <br />0 5 °a <br />W <br />w <br />W <br />O w COLU <br />w~ Q Lu <br />J <br />0 <br />Y Z Z <br />Q Q V <br />F <br />Wes__jQOQmQ,_0oo_'o <br /><axJZ��Z�O1 <br />DO9 <br />o�WoLL oo00 <br />a~ <br />z <br />00 <br />Z <br />0W-zWW <br />8Z <br />O <br />Q0W��� <br />55'rwQ::) <br />oa. <br />v��wO <br />cQ <br />0Yzg¢ <br />u.Q <br />O <br />Ha-QLL. <br />O <br />O <br />Z CV <br />OF- <br />> (n O <br />� J U? <br />w ti <br />z <br />F- W M <br />00 <br />< <br />Z U F- <br />WW <br />JQ <br />A <br />N <br />N <br />0 <br />N <br />A� <br />1 _ <br />(V <br />O <br />O <br />00 <br />C0 <br />00 <br />T-- <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />N <br />N <br />O <br />CD <br />N <br />O <br />N <br />O <br />N <br />CD <br />N <br />o <br />N <br />o <br />N <br />CD <br />N <br />/�/� <br />N <br />00 <br />O <br />to <br />00 <br />O <br />M <br />" <br />N <br />O <br />Mw <br />O <br />c <br />o <br />, <br />0 <br />o� <br />0 <br />o <br />o <br />o <br />6 <br />0 <br />N <br />; <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />N <br />M <br />1 d' 1 <br />LO <br />I f0 I <br />ti <br />00 <br />Z Z <br />O <br />O <br />wo�Q <br />wwU) <br />cy)F- <br />o <br />�� <br />-0 <br />VJ <br />z <br />13- WI=--Q <br />W <br />I._X <br />=m0Z <br />F- Z <br />N <br />n <br />vZ>J <br />00 <br />W>-WM <br /><z0 <br />M <br />CL <br />Z Z u- <br />0O <br />W tV <br />0g <br />z <br />O <br />< <br />US2Zz <br />Z <br />�QO <br />Se <br />Z <br />U <br />� <br />oU <br />0 <br />W <br />Z <br />Q <br />z <br />z <br />w <br />J <br />N <br />" <br />W <br />0 <br />Q <br />LAST PLOT <br />DATE <br />Aug. 8, 22 <br />z <br />0 <br />1 ST & 2ND FLOOR <br />J <br />ELECTRICAL PLAN <br />B <br />-� <br />m a� <br />■� <br />
The URL can be used to link to this page
Your browser does not support the video tag.