- - L9La u Y u l l <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANELCENTER <br />#14 to lights & outlets <br />NEMA 1 0 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 01 #10 to WH <br />10 #8 to Range <br />11 #6 to HVAC <br />so=vo <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />isconnect <br />SERVICE BY POWER CO. <br />4 Bare Cu Ground <br />•Y/�{�� <br />INTERSYSTEM <br />"All <br />BONDING <br />O <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />7f <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />P4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUST FAN <br />;Q� <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />FP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />HD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />V (I Zit <br />AV _vTp <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />® TELEVISION (OPTIONAL) AC PAD / <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. _ <br />i <br />O db 3 <br />T THERMOSTAT �� GI <br />ELECTRIC METER <br />DEDICATED RECEPTACLE <br />ELECTRIC PANEL H•B• FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />_M,=L <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />15'-0" <br />VERIF METER <br />LOCATION WITH <br />BUILD R H.B. <br />r-1 <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=1'-0" <br />eri <br />N <br />•— <br />o <br />J <br />d � <br />� <br />W <br />o <br />N <br />.r G LL d <br />a. - <br />IA lV t <br />Vf y o /0 <br />lV Y <br />3=" <br />e o.er c <br />'a E t c <br />3 cc <br />!o y y 02 <br />02 <br />� c a <br />G <br />o <br />a � <br />w <br />M <br />N <br />N <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />vc <br />C J <br />Y <br />O <br />8, <br />to C? In � LL LL <br />NMC.V� LL <br />IA <br />�-li <br />M LL a ci <br />Z <br />Z <br />N c: a 0 <br />L l9 's <br />Wrnn2°'6. <br />_ <br />� N tD m j Q <br />� K <br />LL Z <br />Z <br />� NZ ��_ <br />M <br />N U Cn F <br />o ❑❑❑ <br />Z <br />W <br />t3 <br />Z Cl) <br />z <br />z <br />� <br />Q <br />a <br />- N <br />(7 <br />Z 9 <br />�N <br />� a <br />U <br />0 <br />w 8 <br />V) <br />c <br />w W <br />SO <br />r 8 <br />1 <br />z <br />U 0 <br />c W I <br />Q C g <br />• <br />Q <br />o <br />90Z-'Z� <br />CC> <br />h c <br />o <br />�o <br />>s <br />Q <br />Eo <br />V <br />wz <br />® <br />❑a <br />H r6 <br />O>= <br />20 <br />¢4 <br />Uo <br />Ord <br />Z <br />r6 <br />1— <br />a0 <br />r <br />WZ <br />n J <br />? C <br />< <br />U <br />mO <br />r <br />Z <br />ZC <br />COm J <br />o <br />¢ <br />¢w <br />2 Z <br />8 <br />a0 <br />W <br />oa <br />' <br />z <br />yW <br />CS <br />yE <br />z <br />�3 <br />x <br />o <br />wF <br />ao <br />zla <br />a <br />3 <br />12 <br />LO <br />t^ <br />Y' <br />N <br />m <br />^ <br />QCID <br />c� <br />CO <br />CN <br />0 <br />C <br />0 <br />T <br />m <br />U) <br />� <br />N <br />Co <br />C <br />LO <br />t— <br />Q <br />L <br />N <br />0) <br />ca <br />04 <br />CD <br />N_ <br />T— <br />TT <br />vi <br />LO <br />co <br />E <br />c O <br />M <br />Z <br />f0 <br />: <br />N <br />N <br />C <br />C <br />a <br />v -1 <br />Q o <br />JOB <br />NO: <br />23-06145 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />