Laserfiche WebLink
0 2ND FLOOR - PARTIAL FLOOR PLAN <br />SCALE: 3/16" = 1'-0" <br />WALL LEGEND <br />4° <br />T`r'P.' <br />DOOR SYSTEM - REFER TO DOOR SCHEDULE - SHEET Aga <br />0 <br />® WINDOW SYSTEM - REFER TO WINDOW SCHEDULE - SHEET 49c <br />METAL STUD PARTITION - REFER TO TYPICAL NON -RATED <br />WALL PARTITION DETAIL A/AIO <br />METAL STUD SOUND INSULATED PARTITION - REFER TO <br />TYPICAL NON -RATED WALL PARTITION DETAIL A/A10 <br />METAL STUD I-HR RATED PARTITION - REFER TO TYPICAL <br />FIRE RATED WALL PARTITION DETAIL 4/LS2 <br />----� METAL STUD LOW WALL PARTITION - REFER TO TYPICAL <br />LOW WALL PARTITION DETAIL 5/AI0 <br />1T C.M.U. WALL SYSTEM - SEE STRUCTURAL DRAWINGS <br />KEYED NOTES <br />0 5/8" GYPSUM WALL BOARD ON I" x 3" P.T. FURRING STRIPS ON <br />CONCRETE BLOCK WALL SYSTEM <br />O0 STRUCTURAL STEEL COLUMN - SEE STRUCTURAL DRAWINGS. <br />0 6" METAL STUD EXTERIOR FRAMED WALL SYSTEM WITH SMOOTH <br />SAND FLOAT FINISH STUCCO. SEE WALL SECTIONS AND STRUCTURAL <br />DRAWINGS. SEE DETAILS ON SHEET A10. <br />ORECESSED PEDIMAT - SEE FINISH SCHEDULE. <br />OROOF DRAIN LEADER - SEE ROOF PLAN <br />OOVERFLOW ROOF DRAIN LEADER - SEE ROOF PLAN <br />OALUMINUM DOWNSPOUT - SEE ROOF PLAN. PROVIDE SPLASH <br />BLOCK AS REQUIRED. <br />OLINE OF KNEE WALL BELOW, <br />OWOOD VENEER BOX AND WALL FINISH AROUND CHECK -IN WINDOW - <br />SEE MILLWORK DRAWING PACKAGE. <br />I;D SCALE - PROVIDED BY OWNER <br />II BOX -OUT WITH 5/8" G.W.B. OVER METAL STUD FRAMING AS REQUIRED. <br />KEEP SIZE TO A MINIMUM - SEE DIMENSIONED FLOOR PLAN. <br />12 FLAT PANEL T.V. BY OWNER - VERIFY EXACT HEIGHT AND <br />LOCATION. PROVIDE WALL BLOCKING AS REQUIRED, <br />13 5/6" GWB OVER I" x 3" FURRING OVER I" RIGID INSULATION ON CMU <br />WALLS FROM SLAB TO UNDERSIDE OF FLOOR/ROOF DECK ABOVE. <br />14 LOW WALL WITH WOOD CAP - SEE DETAIL 5/A10. <br />IS WALL MOUNTED UPPER CABINETS - SEE INTERIOR ELEVATIONS. <br />16 42" HIGH COUNTER/CABINETS - SEE INTERIOR ELEVATIONS, <br />Il 36" HIGH BASE CABINETS/COUNTERTOP - SEE INTERIOR ELEVATIONS <br />IS 30" HIGH BASE CABINETS/COUNTERTOP - SEE INTERIOR ELEVATIONS <br />19 2'-10" HIGH BASE CABINETS/COUNTERTOP - SEE INTERIOR ELEVATIONS. <br />20 DISHWASHER - PROVIDED BY OWNER, INSTALLED BY G.G. <br />21 STAINLESS STEEL SINK - SEE PLUMBING DRAWINGS. <br />22 SERIES "SGD-2500 DRY -GLAZED" ALUMINUM HORIZONTAL SLIDING <br />WINDOW - N.I. - SEE INTERIOR ELEVATIONS. <br />23 REFRIGERATOR - PROVIDED BY OWNER <br />24 UNDER COUNTER REFRIGERATOR - PROVIDED BY OWNER <br />25 COPIER - PROVIDED BY OWNER <br />26 FIRE EXTINGUISHER CABINET - SEE DETAIL 2/1_62 AND 3/1-62. <br />21 WALL MOUNTED FIRE: EXTINGUISHER. <br />28 FIXED SHELVING - SEE CABINET DETAILS <br />29 ALIGN PARTITION WALL WITH WINDOW JAMB. <br />30 MOP SINK WITH WATER HEATER ABOVE ON SHELF - SEE PLUMBING <br />DRAWINGS. PROVIDE FRP, 4'-0" HIGH, ABOVE MOP SINK, <br />31 EXAM ROOM PRIVACY CURTAIN AND RAIL SYSTEM - SEE FINISH SCHEDULE. <br />32 PROVIDE AUTO CLOSER ON DOOR. <br />33 ONE HOUR RATED PARTITION - SEE DETAIL 4/L52. <br />34 RECESSED SPECIMEN PASS-THRU CABINET - SEE DETAIL 1/Alj. <br />35 FAUCET MOUNTED EYE WASH STATION - SEE PLUMBING DRAWINGS. <br />36 5/6" GYPSUM WALL BOARD ON 3-5/8" METAL STUD ON CONCRETE <br />BLOCK WALL SYSTEM WITH R-11 INSULATION. <br />31 8" CONCRETE BLOCK WALL SYSTEM - SEE STRUCTURAL DRAWINGS. <br />PROVIDE PARGE COAT STUCCO. <br />38 PLASTIC LAMINATE BENCH - SEE INTERIOR ELEVATIONS. <br />(311EQUIPMENT BY OWNER. <br />40> 30" x 48" CLEAR FLOOR SPACE INDICATED AS "AREA OF RESCUE <br />ASSISTANCE". <br />41 AREA OF RESCUE ASSISTANCE SIGN AND TWO-WAY EMERGENCY <br />COMMUNICATION SYSTEM, INSTRUCTIONS FOR SUMMONING ASSISTANCE VIA T <br />TWO-WAY COMMUNICATION SYSTEM AND WRITTEN IDENTIFICATION OF THE <br />LOCATION SHALL BE POSTED ADJACENT TO THE TWO-WAY COMMUNICATION <br />SYSTEM. SIGNAGE SHALL COMPLY WITH THE ICC A 111.1 REQUIREMENTS FOR <br />VISUAL CHARACTERS. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION <br />42 ROOF ACCESS LADDER WITH HATCH ABOVE - SEE ROOF PLAN. <br />43 VENDING MACHINE - VERIFY TYPE WITH OWNER. <br />GENE iZ4L NOTES <br />I. SEE DETAIL A/AIj FOR DOOR MANEUVERINGS DETAIL. <br />2. PREPARE CONCRETE SLAB AS REQUIRED TO RECEIVE NEW FINISHES. <br />3. SEE DOOR AND WINDOW SCHEDULE AND DETAILS FOR ALL DOORS AND WINDOWS <br />INFORMATION. <br />4. SEE ID SHEETS FOR ALL FINISH SCHEDULES. <br />5. ALL GYPSUM WALL BOARD TO HAVE LEVEL (4) FINISH. LEVEL (5) FINISH IN <br />PHARMACY, ROOM NO. 203% <br />6. PROVIDE 5/8" GYPSUM WALL BOARD ON I" x 3" FURRING STRIPS OVER I" RIGID <br />INSULATION ON INSIDE OF ALL EXTERIOR CMU WALLS. INSULATION AND GYPSUM <br />WALLBOARD TO EXTEND FROM FLOOR TO FLOOR OR ROOF DECK ABOVE. <br />1. COORDINATE LOCATION OF PLUMBING STACKS WITH FLOOR PLAN LAYOUT. NOTIFY <br />ARCHITECT WITH ANY DISCREPANCIES UPON DISCOVERY. <br />KEY PLAN <br />REVISIONS <br />BY <br />r•/ J <br />In 00 <br />CO <br />C`n N <br />— <br />o <br />r y N O <br />Y ti <br />rn � [ _ <br />/ CL <br />Np <br />C . U <br />c> U N <br />- Ln <br />it Q E <br />Q rn 0 o <br />~ <br />Y T <br />3 <br />�—� N <br />0 <br />/ aj <br />� c <br />v ti 0. <br />co <br />M <br />d. <br />pax <br />0_E±= <br />k90 <br />_ W <br />t3c�E-r- <br />Z,_ <br />^i> <br />w- <br />a0— <br />+ 0;0 <br />)��_ <br />Q • cCy <br />61 'No, •. Q <br />LL <br />�' r :0 <br />0- 1 <br />;`,`G' <br />,4 <br />lea:1 <br />0 c <br />J <br />Q. -3 <br />U <br />Z O <br />v� <br />O O N <br />Ln <br />' � M <br />O M <br />m J E �. <br />Q <br />" U � <br />•O <br />4 <br />Lj <br />O M <br />L_. <br />_ W O <br />U <br />vj (n V) <br />< O <br />m -C <br />a <br />N O:f N <br />z 0 0 <br />v <br />J ;i <br />L._ <br />Date: 02. 13. 18 <br />Scale: AS NOTED <br />Project Mgr: AAY <br />Drawn: JDS <br />Job: 15-025 <br />Sheet <br />A2c <br />WProjects\Projects 2015\15025 - FMC Eiland Blvd Expansion\04-CD\01-CD.A\04-Architectural\A2abcdef - 2nd Floor- FLPL.dwg, 2/9/2018 8:39:13 AM, JSimon, Xerox 6604 PS.pc3 <br />