ELECTRICAL SPECIFICATION 150A/2 C INDOOR PANELLCENTER <br />NOTES: 0 #14 to rights & outlets <br />NEMA 1 01 #12 to appliances and GFI <br />150 AMP/ <br />ELECTRICAL CONTRACTOR 200 AMP 10 #10 to WH <br />MUST VERIFY WITH THE 10 #S to Range <br />SPECIFICATIONS FOR THE TYPE 10 #6toHVAC <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR METER <br />LOCATION PURPOSES. ` <br />v 50=2/0 <br />J <br />200=4/0 in 2" Conduit <br />200 amp <br />150 amp <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in LIL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/LlL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />O <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />Ja <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />a <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />UNDERGROUND Disconnect <br />SERVICE BY POWER CO. <br />Bare Cu Ground <br />INTERSYSTEM <br />4 <br />BONDING GRGROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />AC PAD <br />DISC. WP <br />GFI <br />�o A <br />r —_-1 ■ @11 r <br />if II <br />II ALT II <br />jl AC PAD Ij <br />Il 11 = <br />WP DINING � <br />CO / <br />OPT. D <br />LIGHT AS PER <br />SPECS <br />PENDANT <br />LIGHT PER <br />SPECS <br />GREAT RM <br />am ROUGH -IN <br />FOR OPT. U.C. OUTLET <br />3 <br />I LL <br />-- <br />I I?3� N <br />i16 <br />L--J - <br />U.C. OUTLET W <br />0 3 KIT. a <br />SWITCH FOR FII <br />DISPOSAL I I - -- ; <br />I <br />II LL <br />- <br />X <br />aF1 N - <br />W <br />I I / L <br />I I f <br />f - - : 7� <br />-.. <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />an •� <br />----LANAA1---- <br />/> I <br />I I <br />V <br />�� <br />I i Ak <br />_ <br />BRKF-ST <br />LIGHT AS PER <br />SPECS <br />5'-0i" \ <br />_ <br />GFI - <br />- --- <br />IGFI I <br />I -- - <br />1GFI <br />II <br />IEOEI <br />I M <br />FAN/LIGHT c/ / <br />J SWITCH FOR F[i i <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE/ I <br />DISPOSAL I , IT - <br />II <br />/ <br />GFI <br />wW <br />I I 1'-10" <br />iv <br />2'-$' <br />V-10" <br />' C.M <br />\ <br />I I -II <br />CH <br />3 �_ <br />• <br />— — — <br />M <br />- <br />IGT AD <br />IV <br />�—I --- <br />I�,�I <br />�% <br />w <br />CIO A O <br />E I I <br />D_ <br />I I I <br />I I I I I <br />III ► I , <br />II I I I <br />I I 1""T <br />I I <br />-_ ——r— — <br />J—J'' <br />FOYER <br />GFI @ 44" <br />A.F.F. , <br />W.H. <br />I <br />I <br />Z W <br />ga <br />IZ <br />DB <br />\ <br />GARAGE <br />AS <br />> — <br />F- <br />GFI <br />LIGHT <br />PER SPECS <br />LL <br />1 <br />W w <br />GARAGE,/ <br />' W <br />• <br />0 <br />1 <br />i� IaARAGE <br />ENTRY <br />DOGR <br />I I <br />FI <br />I <br />I I <br />-- <br />I <br />I I <br />- ___—___ j <br />I <br />I <br />IRRIGATION <br />I <br />GFI <br />@44"A. F.F. <br />I <br />I <br />/ <br />I <br />I <br />I <br />I <br />� <br />I <br />I <br />� <br />I <br />--------------- <br />,�----------COAMIFGRTS---------- <br />OR PREWIRE AS <br />PER SPECS <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />I— <br />WZ <br />�OW <br />0 m <br />I-------------------� <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />3" <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />CENTER <br />GFI @ <br />44" A.F.F. <br />pl 3" VTR 1.5" VTR <br />I� III <br />I� <br />I I <br />I I <br />I I <br />I <br />� I I <br />—III 3" VTR <br />I � I I, <br />I � I <br />I r I I <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN_ <br />e� <br />N <br />0 <br />N <br />c <br />> W <br />—J <br />o <br />w n <br />o- , c-, <br />V <br />N <br />>C <br />a <br />N <br />fhi O <br />•y 'd !V .G <br />N y O J <br />tv <br />3 cc <br />cca tv <br />w Co <br />y �.a <br />C <br />eo <br />0 <br />d w <br />0 <br />w <br />M <br />O <br />N <br />M <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />N <br />N8 N� <br />N ap <br />O J <br />o9 <br />LL a tail <br />iiLL <br />Q <br />a"!0ty <br />ry <br />Z <br />z <br />Z <br />W <br />t m� <br />�o(0M2 o <br />uj <br />'of6�� <br />WWIL1 <br />�2� QJm <br />w <br />IL <br />; <br />Pf Z y ~ <br />V <br />N <br />00❑00 <br />Z <br />W <br />R <br />Z N th <br />z � <br />Z � <br />a <br />Q) <br />to <br />ct.- <br />N <br />M <br />z <br />� <br />U o <br />V <br />w W <br />� <br />V <br />0 <br />V1 <br />c <br />U <br />,,, <br />�® <br />= t g <br />I <br />0 <br />N W <br />o <br />_ <br />LL <br />E <br />� E <br />O <br />— <br />Q N <br />Q <br />o <br />E U <br />�� <br />W z <br />_® <br />oa <br />o U <br />Q2�= <br />Io <br />ZZCO <br />WJOZZ <br />Z'zFG <br />=NO <br />mO.a <br />QWZ <br />Z02 <br />W <br />ao <br />co <br />� <br />1- <br />MO <br />M <br />~ <br />= <br />Mj <br />� <br />r <br />zla <br />h <br />0 3 <br />2o <br />-17 <br />> Lin <br />rn <br />m <br />c� <br />M <br />T <br />/'%% <br />Q <br />Cr <br />co <br />W m <br />N <br />4 <br />LO <br />O <br />M <br />M <br />~0 <br />N <br />L0 <br />QCV) <br />0 <br />�-- <br />T <br />M M <br />o <br />M <br />LO <br />Z <br />Z <br />E r <br />d <br />W <br />a <br />0 -j <br />¢ o <br />JOB <br />NO: <br />23-06110 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />