Laserfiche WebLink
REFLECTED CEILING LEGEND <br />2' x 2' SUSPENDED CEILING GRID SYSTEM WITH 2' x 2' <br />LAY -IN ACOUSTICAL CEILING TILES <br />FINISH) <br />G.W�5 CEILING (SMOOTH <br />2' x 4'FLUORE5C—ENT LIGHT FIXTURE, LAY IN AT <br />SUSPENDED CEILING GRID SYSTEM - SEE ELECTRICAL <br />FOR MORE INFORMATION <br />_21 2' x 4'FLUCRE&CENT EMERGENCY LIGHT FIXTURE, LAY IN <br />ELECTRICAL FOR MORE INFORMATION <br />FI= AT SUSPENDED CEILING GRID SYSTEM - SEE <br />2' x 2'FLUORESCENT LIGHT FIXTURE, LAY IN AT <br />SUSPENDED CEILING GRID SYSTEM - SEE ELECTRICAL <br />El FOR MORE INFORMATION <br />"011 <br />RECESSED CAN DOWN LIGHT FIXTURE - SEE <br />ELECTRICAL FOR MORE INFORMATION <br />EMERGENCY RECESSED CAN DOWN LIGHT FIXTURE - <br />SEE ELECTRICAL FOR MORE INFORMATION <br />WALL MOUNTED LIGHT FIXTURE - SEE ELECTRICAL FOR <br />MORE INFORMATION <br />EXIT LIGHT FIXTURE - SEE ELECTRICAL FOR MORE <br />INFORMATION <br />EXHAUST FAN - SEE MECHANICAL FOR MORE <br />INFORMATION <br />MEC14ANICAL SUPPLY REGISTER SEE MECHANICAL <br />FOR MORE INFORMATION <br />MECHANICAL RETURN REGISTER SEE MECHANICAL <br />FOR MORE INFORMATION <br />WALL MOUNTED LIGHT FIXTURE - SEE ELECTRICAL FOR <br />MORE INFORMATION <br />KAE—YED NOTES <br />0 OUTI INE OF WALL MOUNTED UPPER CABINETS / SHELF - SEE <br />INTERIOR ELEVATION$ <br />(D CEILING MOUNTED CUBICLE CURTAIN TRACK - SEE ID SHEET <br />(D STUCCO SOFFIT / G.We. CEILING - SEE WALL SECTIONS AND CEILING <br />DETAILS <br />GNO CEILING IN THIS AREA - EXPOSED TO STRUCTURE <br />(D WOOD CORNER MOLD - HHH -165 <br />GWOOD CROWN MOLD - HHH 105 WITH ix2 WOOD TRIM - SEE <br />DETAIL (o1A3b <br />0 CONTROL JOINT IN STUCCO CEILING <br />GG.W.5. WRAPPED DROP HEADER SEE DETAILS <br />GG.WZ. WRAPPED FLUSH HEADER SEE DETAILS <br />GENERv4L NOTES <br />1. ALL CEILING HEIGHTS SHALL BE 10'-V UNLESS OTHERUJ15E NOTED <br />2. ALL METAL FRAMING FOR GYPSUM WALLBOARD CEILING SHALL BE 25 <br />GAUGE - 3 5/a INCH WITH MINIMUM 30 10 SHEET METAL SCREW$ PER <br />CONNECTION. <br />3. GENERAL CONTRACTOR TO NOTIFY ARCHITECT OF ANY <br />DISCREPANCIES PRIOR TO COMMENCING WITH ANY WORK. <br />4. SEE ELECTRICAL DRAWINGS, FOR ALL LIGHT FIXTURES <br />SPEC IFICAT IONS. <br />5. GENERAL CONTRACTOR TO COORIDINATE ALL PROPOSED CEILING <br />HEIGHTS WITH STRUCTURAL AND MECHANICAL DRAWINGSAND NOTIFY <br />ARCHITECT WITH ANY DISCREPANCIES UPON DISCOVERY BEFORE <br />COMMENCING WITH ANY WORK- <br />(o. SEE SHEET IDI FOR CEILING FINISHES. <br />-1. MTL. STUDS SHALL BE CONNECTED TO STRUCTURAL 5%. W1 (3) 0.145"0 <br />RAM-5ET POWDER DRIVEN FASTENERS. <br />a. MTL. STUDS/CLIP ANGLE SHALL BE CONNECTED TO MTL. STUDS wl MIN <br />(4) 012-14 TEK SCREWS. <br />c3. CONTINUOUS TRACK SHALL BE CONNECTED TO STRUCTURAL STL. w/ <br />(2) 0,145"0 RAMSET POWDER DRIVEN FASTENERSAT 16" O.C. <br />10. CONTINUOUS TRACK/STUD6/CLIP ANGLES SHALL 5E CONNECTED TO <br />CONCJCMU w/ (2)1/4"0 x 1 1/4" TAPCON FASTENERS AT 24" O.C. <br />11. CONNECT SHEATHING TO MTL. STUDS w/ 012-14 TEK SCREW& AT (p" O.C. <br />12. CONTINUOUS TRACK SHALL BE CONNECTED TO ROOF DECK w/ (2) 010 <br />TEK SCREWS AT 24" O.C. <br />13. AS REQUIRED, THE CONTRACTOR SHALL PROVIDE CLIP ANGLES FOR <br />ALL METAL STUDS 80 PROPER AL IGNMENT CAN BE ATTAINED. CLIP <br />I I ANGLES SHALL MATCH OR EXCEED THE STUD GAGE. <br />14. FOR ALL MOLDINGS CONTACT TRIPLE H INDUSTRIES - GLEN HULTGREN <br />121-204-0531 <br />R.IEFLECTED CEILIN16k.-we PLAN <br />SCALE: 311(o" a V-01' <br />