M <br />EDICAL C�,43 NOT�3 <br />EDICAL GAS SYSTEM DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING <br />RD DRAWINGS WHICH MAY NOT REFLECT ACTUAL FIELD CONDITIONS. THE <br />ACTOR SHALL VERIFY THESE DRAWINGS WITH EXISTING FIELD CONDITIONS <br />ND NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY OF INCONSISTENCIES <br />EN THE DRAWINGS AND ACTUAL CONDITIONS BEFORE PROCEEDING WITH <br />RUCTION. <br />ONTRACTOR SHALL NOtfFY THE ARCHITECT /ENGINEER fMMEDIATELY <br />OF THE WORK INDICATED IN THE CONTRACT DOCUMENTS CANNOT <br />RFORMED DUE TO EXISTING FIELD CONDITIONS. <br />3. THIS CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE MEDICAL GAS <br />SYSTEMSt INCLUDING ALL ASSOCIATED DEVICES, EQUIPMENT AND CONNECTIONS <br />TO EXISTING SERVICES, SUPPORTS, AND HARDWARE REQUIRED FOR TESTING, <br />AND FOR SATISFACTORY OPERATION OF THE SYSTEMS. <br />4. THIS CONTRACTOR SHALL PROVIDE ROUTING AND OFFSETS NECESSARY TO <br />AVOID CONFLICT WITH STRUCTURE, FINISHES, AND WORK OF OTHER TRADES. <br />5. WALL AND PARTITION CONSTRUCTION AND THICKNESS FOR MEDICAL GAS <br />OUTLETS, VALVES t PIPING AS INDICATED SHALL BE AS PER EQUIPMENT <br />MANUFACTURERS RECOMMENDATIONS AND APPROVED SHOP DRAWINGS. <br />6. THE MEDICAL GAS PIPING SYSTEM SHALL BE INSTALLED IN ACCORDANCE <br />WITH NFPA-99 (2005) STANDARDS, <br />APPLICABLE CODES, <br />REGULATIONS AND EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. <br />1. ALL MEDICAL GAS WALL OUTLETS SHALL BE CHEMTRON COMPATABLE CONNECTION <br />STYLE UNLESS OTHERWISE NOTED - <br />CONTRACTOR TO FIELD VERIFY COMPATA151LITY OF ALL MED GAS OUTLET <br />REQUIREMENTS PRIOR TO CONSTRUCTION. <br />5. THE NEW MASTER AND AREA ALARM PANELS SHALL BE <br />TESTED BEFORE FINAL AHCA INSPECTION. PROVIDE ALL LABOR <br />AND MATERIAL FOR PROPER OPERATION OF THE ALARM SYSTEM. <br />9. AFTER COMPLETION OF THE SYSTEM INSTALLATION, THE SYSTEM SHALL <br />BE PURGED AND TESTED AS OUTLINED IN NFPA-99 (2005). PLUMBING <br />CONTRACTOR SHALL PROVIDE THE OWNER W/TEST REPORT AND MEDICAL <br />GAS SYSTEM CERTIFICATION DOCUMENT PRIOR TO USE OF THE SYSTEM. <br />10. SEE PLAN FOR MEDICAL GAS PIPE SIZING. <br />11. MEDICAL GAS PIPING SHALL BE SEAMLESS COPPER TUBING, TYPE "K" OR <br />"L", HARD TEMPER, ASTM 8-819 FOR ASSEMBLY WITH SOLDERED FITTING AND <br />SHALL BEAR OF THE FOLLOWING MARKINGS: OXY, MED, OXY/MED, ACR/OXY <br />OR ACR/MED. PIPING DELIVERED ON SITE FOR MEDICAL GAS INSTALLATION <br />SHALL BE CLEANED AND CAPPED ON BOTH ENDS. FITTING AND JOINTS SHALL <br />BE WROUGHT COPPER DESIGNED FOR BRAZING. FOR PIPING ASSEMBLY AN <br />APPROVED SILVER BRAZING ALLOY (BAG SERIES) HAVING OVER 1000 F <br />DEGREES MELTING POINT TEMPERATURE SHALL BE USED. AIRCOSIL FLUX OR <br />EQUAL SHALL BE EMPLOYED. BORAX AND ALCOHOL MIXTURES OR RESINS AND <br />SIMILAR PASTE FLUXESSHALL NOT BE USED <br />12. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEERS <br />APPROVAL FOR ALL EQUIPMENT AND MATERIAL SHOWN OR SPECIFIED ON THE <br />DRAWINGS. <br />13. PROVIDE APPROVED MEDICAL GAS IDENTIFICATION MARKS FOR ALL <br />MEDICAL GAS PIPING. MAXIMUM DISTANCE BETWEEN MARKS SHALL BE <br />MAX. 15'-0" <br />14. THE ENTIRE INSTALLATION AND WORKMANSHIP SHALL BE GUARANTEED <br />FREE FROM DEFECTS FOR A PERIOD OF ONE (1) YEAR OF FINAL <br />ACCEPTANCE AND CERTIFICATIONS. <br />15. PROVIDE MEDICAL GAS SYSTEM CERTIFICATION REPORT BEFORE <br />FINAL INSPECTION. CERTIFICATION TO BE PROVIDED BY INDEPENDENT THIRD <br />PARTY AGENCY SUCH AS MCMC OR EQUAL. <br />16. ALL LOW VOLTAGE ALARM WIRING t0 BE PULLED t INSTALLED BY MEDICAL GAS <br />EQUIPMENT SUPPLIER AND TO INCLUDE FINAL TERMINATIONS. <br />O MEDICAL GAS NOTES, EQUIPMENT SCHEDULES t LEGEND <br />N.i.5. <br />MEDICAL GAS SET INDEX <br />MG1 MEDICAL GAS NOTES, SCHEDULES t LEGEND <br />MG2 MEDICAL GAS FLOOR PLAN <br />MG3 MEDICAL GAS DETAILS <br />MEDICAL GAS LEGEND <br />DESCRIPTION <br />SYMBOL <br />NEW VACUUM PIPING <br />— — — —V— — — — <br />NEW OXYGEN PIPING <br />0 <br />NEW POINT OF CONNECTION <br />NEW PRESSURE TRANSDUCER SWITCH <br />■ <br />NEW MASTER AREA ALARM PANEL <br />r-= <br />MEDICAL GAS WALL OUTLET <br />T_= O <br />NEW GAS ZONE VALVES AND BOX <br />W/PRESSURE GAUGE ASSEMBLIES <br />A.HJ. <br />AUTHORITY HAVING% JUR16DICTION <br />U.OTL <br />UNLESS OTHERWISE NOTED <br />AFF <br />ABOVE FINISHED FLOOR <br />P:C. <br />PLUMBING CONTRACTOR <br />G C. <br />I GENERAL CONTRACTOR <br />MEDICAL N��E QUIF MENT 3CNEDULE <br />MARK <br />DESCRIPTION <br />MARK <br />DESCRIPTION <br />OUTLET <br />OWALL <br />ONE (l) OXYGEN (1) VACUUM OUTLET t ll) WALL SLIDE <br />THE VACUUM PUMP PACKAGE ASSEMBLY SHALL INCLUDE DIRECT DRIVEN VACUUM PUMPS, <br />MEDICAL SERVICE OUTLETS SHALL BE CONCEALED WALL OUTLETS, COMPLETE ASSEMBLY <br />GAL VACUUM RECEIVER (ASME CODE STAMPED), INTAKE PIPING, FLEXIBLE <br />TYPE G>111CK-CONNECT CHEMTRON COMPATIBLE FROM AMIGO: <br />CHE <br />CONNECTORS, ISOLATION VALVES, CHECK VALVES, NTERWNNECTING PIPING AND FITTINGS, <br />FORQJICOXYGEN: �N CT -OXY <br />DUPLEX CONTROL SYSTEM (NEMA 12 t U.L. LABELED), THE CONTROL SYSTEM SHALL <br />PROVIDE AUTOMATIC LEAD/LAG SEQUENCING WITH CIRCUIT BREAKER DISCONNECTS FOR <br />FOR VACUUM: 40-CHWAL-U-VAC <br />EACH VACUUM PUMP WITH EXTERNAL OPERATORS, FULL VOLTAGE MOTOR STARTERS WITH <br />WALL SLIDE 00-WALOLIDE <br />OVERLOAD PROTECTION, REDUNDANT 120V CONTROL CIRCUIT TRANSFORMERS, VISUAL AND <br />AUDIBLE RESERVE UNIT ALARM, WITH ISOLATED CONTRACTS FOR REMOTE ALARM, <br />ATT <br />LOW t HIGH PRESSURE SWITCHES <br />HAND -OFF -AUTO LIGHTED SELECTOR SWITCHES AND RUNTIME HOURMETERS. PROGRAMMABLE <br />HIGH -LOW LINE PRESSURE SWITCH FOR OXYGEN, NITROUS OXIDE, MEDICAL AIR, CARBON DIOXIDE t <br />LOGIC CONTROLLER (PLC) SHALL CONTROL THE AUTOMATIC ALTERATION OF BOTH VACUUM <br />VACUUM SERVICES SHALL BE LOCATED ON THE PIPE LINES AS PER NFPA-99 (2005) STANDARDS. <br />PUMPS WITH PROVISIONS FOR SIMULTANEOUS OPERATION IF REQUIRED, AND AUTOMATIC <br />THE SWITCHES, DISS DEMAND CHECK PORTS, AND PRESSURE SWITCHES SHALL BE AMICO <br />ACTIVATION OF RESERVE UNIT IF REQUIRED. THE CONTROL SYSTEM SHALL INCLUDE AN <br />PART NUMBER AS LISTED BELOW OR APPROVED EQUAL. <br />AUTOMATIC MINIMUM RUN TIME ADJUSTMENT TO CONTROL RUN TIME BASED ON DEMAND. THE <br />PRESSURE SWITCHES: <br />VACUUM GAUGES SHALL BE PROVIDED IN THE CONTROL PANEL. <br />• M-PRSW-OXY FOR OXYGEN, <br />THE SYSTEM SHALL BE AMICO MODEL NO. V-RVL-D-080-TS-N-015 WITH, IB HP CONTINUOUS <br />0 M-PRSW-VAC FOR VACUUM <br />DUTY NEMA RATED, C-FACE, OPEN DRIP PROOF, IWO RPM, MOTOR FOR 480V, 60 HERTZ, 3 <br />PHASE ELECTRICAL SERVICE. THE SYSTEM CAPACITIES SHALL HAVE A MINIMUM OF 1 SCFM • <br />CHECK PORTS: <br />19' Hg PER SINGLE VACUUM PUMP (RESERVE VACUUM PUMP ON STANDBY) AS PER NFPA-99 <br />M/-CHK- PIPE SIZE AS REQUIRED FOR OXYGEN, <br />(2005) STANDARDS REQUIREMENTS. <br />PRESSURE GAUGES: <br />M M-PRSW-GA (0 - 100 PSI) FOR PRESSURE GASES, <br />"M-PRSW-GA-VAC FOR (0 - 30 Hg) FOR VACUUM. <br />ALL COMPONETNS INSTALLED AS PER MANUFACTURERS RECOMMENDATION) <br />OYGEN MANIFOLD: <br />AUTOMATIC CHANGE OVER MANIFOLD ASSEMBLED AND TESTED SHALL BE AMIGO NEMA 4 <br />PRESSURE GAUGES: <br />(WEATHER -TITS RATED) (1) fM2-HD-DL-HH-U-OXY MANIFOLD, 2 X 2 M2-H5XC-04U-OXY <br />%-130112-00 FOR (0 - 100 PSI) FOR PRESSURE GASES, <br />HEADER BARS <br />N 6-130111-00 FOR (0 - 30 Hg) FOR VACUUM. <br />SVl <br />S BODY, AND <br />ISOLATION T- VALVES BALL TYPE (DOUBLE SEAL) WITH CAST , THE VALVES <br />LOCKING DEVICE t CHROME -PLATED BRASS 8,41.E t tEFLON SEALS, THE VALVES SHALL BE AMIGO <br />MEDICAL GAS MANIFOLDS: <br />AUTOMATIC, MICROPROCESSOR BASED DIGITAL CHANGE OVER MANIFOLDS, TESTED, FULLY ASSEMBLED IN <br />WATER TIGHT ENCLOSURE, SWITCHING POWER SUPPLY, WITH BUILT IN FUSE AND THERMAL BLOCKS, TWO <br />PRODUCTS MODEL NUMBERS: <br />HEADER BAR ASSEMBLY WITH CHECK VALVES AND WITH HIGH PRESSURE HOUSES FOR OXYGEN, <br />OXYGEN TO BE 0S-VV-ISO-GL-05, VACUUM N 5-VY-160-GL-12 <br />SERVICES SHALL BE AMICO <br />NUMBER FOR EACH SPECIFIC GAS SERVICE SHALL BE AS SPECIFIED. EACH ASSEMBLY SHALL INCLUDE: <br />- WALL MOUNTING BRACKETS FOR ENCLOSURE, HEADER AND CYLINDERS, <br />- ONE MANIFOLD BLOCK ASSEMBLY (INCLUDES INSTALLATION VALVES, CHECK VALVES, RELIEF VALVES, <br />® <br />COM51RATION MODULAR MASTER/AREA ALARM PANEL (RECESSED WALL MOUNTED) <br />BLEED VALVE, AND DELIVERY LINE PRESSURE GAUGES, t ALARM SIGNAL CONNECTIONS), <br />- TWO VALVE AND CROSS ASSEMBLIES, <br />DIGITAL MODULE AREA ALARM PANEL FOR MEDICAL GAS SYSTEM SHALL BE AMIGO <br />- TWO BANK REGULATOR ASSEMBLIES (INCLUDES INTERMEDIATE AND BANK PRESSURE GAUGES, <br />AND SHALL INCLUDE: <br />- TWO BLANK TUBES, <br />- TWO LINE PRESSURE REGULATOR ASSEMBLIES, <br />ROUGH- IN ASSEMBLY ASSEMBLY, <br />MULTI -SIGNAL ALARM MODULES, <br />- TWO LINE TUBES, <br />- TWO BANK REGULATOR STOP KITS, <br />ANNUNCIATOR MODULE, <br />- ONE PRESSURE SWITCH, <br />- OTHER HARDWARE WITH REQUIRED NUMBER OF BLIND GLANDS AND UNION NUTS, AND PIGTAILS. <br />WITH REMOTE SENSORS <br />MASTER ALARM MODULES SHALL DISPLAY CANCELABLE AUDIBLE t NON -CANCELABLE VISUAL SIGNALS At <br />AND PIGTAILS. <br />IN COMPLIANCE WITH NFPA-SS (2005) AND APPROPRIATELY LABELED FOR EACH REQUIRED SIGNAL. <br />FOR TREATMENT ROOM AND FOR PATIENT CHANGE / RECOVERY ROOM AND EXAM -FITTING ROOM <br />TWO ZONE VALVES AND BOX ASSEMBLIES W/PRESSURE GAUGES <br />® <br />SHUTOFF VALVE SHALL BE BALL -TYPE (DOUBLE SEAL) WITH CAST BRONZE BODY, QUARTER <br />MASTER/AREA ALARM PANEL SHALL BE PART •A2AL-D-OXY-VAC-OXY-VAC-MIN <br />TURN, AND CHROME PLATED BRASS BALL, PRESSURE GAUGES FOR OXYGEN AND VACUUM <br />SERVICES COMPLETE ASSEMBLY FOR RECESSED VALVE BOX. <br />THE VALVE SHALL BE AMICO • Z-V5U-M1205 WITH PRESSURE GAUGES. (SEE PLAN FOR <br />LOCATIONS) <br />NOTES: <br />1. PROVIDE IDENTIFICATION SIGNS BY MEANS OF DURABLE TAGS, NAMEPLATES OR LABELS FOR ALL SERVICE 4. COORDINATE WITH ELECTRICAL CONTRACTOR LOCATIONS AND ELECTRICAL CHARACTERISTICS FOR ALL ITEMS <br />ZONE VALVES t PIPING SYSTEM AND EQUIPMENT ACCORDING TO NFPA-99 ( 2005) STANDARDS. REQUIRING ELECTRICAL SERVICE. <br />2. THE NEW CEILING MOUNTED MEDICAL GAS OUTLETS SHALL BE DISS STYLE. OUTLETS SHALL BE 5. PROVIDE IDENTIFICATION LABELS FOR NEW ISOLATION VALVES IN CEILING SPACE. <br />INSTALLED AS INDICATED ON PLANS. 6. BEACONMEDAES MEDICAL GAS, WESTERN, ALLIED HEALTHCARE PRODUCTS, INC., HILL -ROM A HILLENBRAND IND, <br />3. THE NEW WAL MOUNTED MEDICAL GAS OUTLETS SHALL BE C14EMTRON COMPATIBLE STYLE. TRI-TECH MEDICAL INC. EQUIPMENT TO BE AN EQUAL MANUFACTURER SUBJECT TO OWNERS APPROVAL. <br />OUTLETS SHALL BE INSTALLED AS INDICATED ON DRAWINGS. <br />REVISIONS <br />BY <br />f, <br />00 <br />�--� ao <br />U � co <br />CO N <br />r� o p00 � <br />ti o <br />�xti Y <br />_ U <br />�••� N in N Y <br />N G k <br />y O ro <br />O LO <br />Q O O <br />Y 3 ti 3 <br />tiN . <br />0 <br />•—� � ti ate, <br />� � N <br />10 <br />a <br />° `, 9 P® 411 <br />0. s <br />° <br />�w <br />ors �o <br />ce) ^ A <br />0 <br />=a <br />a m <br />Z �m <br />C c LL$ <br />o2 V �$ <br />G <br />� a <br />C E <br />w �� <br />00 <br />E Us <br />� UZ <br />U �m <br />'m <br />> <br />-o In > s <br />Q _m� .W <br />m <br />w�LQ ma <br />a s" <br />O O r <br />a `a <br />(J <br />� U <br />Z J <br />CL () Z m <br />w W v� <br />-o —� U <br />C Q (/) O <br />Q UW <br />�� <br />o 0=�v� <br />Q L _ <br />W p •— <br />D <br />o�U� <br />C- <br />aCi Q o <br />00 <br />MN <br />-LLJ <br />-� 0 <br />'3 J D <br />m <br />Date: 06. 12. 12 <br />Scale: AS NOTED <br />Project Mgr: AAY <br />Drawn: <br />Job: 10-61 <br />Sheet <br />MG1 <br />