PLU" 5INCH SPECIFICATIONS
<br />PART I - GENERAL
<br />1.01 GENERAL DOCUMENTS
<br />A. THE REQUIREMENTS OF THE GENERAL CONDITIONS t
<br />SPECIFICATION BOOK SHALL APPLY TO ALL
<br />PLUMBING WORK. INSTALLATION SHALL BE IN
<br />ACCORDANCE WITH THE FLORIDA BUILDING CODE
<br />2010 - PLUMBING WITH CURRENT AMENDMENTS.
<br />B. THE PLUMBING WORK SHALL FURNISHING ALL LABOR,
<br />EQUIPMENT, MATERIALS AND SERVICE NECESSARY
<br />FOR AND REASONABLY INCIDENTAL TO THE
<br />PROPER COMPLETION OF ALL PLUMBING WORK
<br />SHOWN ON THE DRAWINGS AND AS SPECIFIED. ALL
<br />MATERIAL SHALL BE NEW EXCEPT WHERE SHOWN
<br />EXISTING.
<br />C. ALL MATERIALS AND EQUIPMENT SHALL BE THE
<br />STANDARD CATALOGED PRODUCT OF A REPUTABLE
<br />MANUFACTURER REGULARLY MANUFACTURING THE
<br />PARTICULAR ITEM, FREE FROM DEFECTS AND IN NEW
<br />CONDITION.
<br />D. IT WILL BE THE RESPONSIBILITY OF THE
<br />CONTRACTOR TO VERIFY ALL GAS REQUIREMENTS
<br />FOR PROPER INSTALLATION AND OPERATING
<br />REQUIREMENTS, BEFORE PIPING IS TO BE INSTALLED.
<br />E. CONTRACTOR TO VERIFY t PROVIDE NEW ROOF
<br />SUPPORTS AND STRAPS FOR ALL EXISTING GAS
<br />LINES. CONTRACTOR TO VERIFY EXACT TYPE t
<br />QUANTITY.
<br />1.02 SUBMITTALS
<br />A. MATERIALS OR PRODUCTS SPECIFIED HEREIN
<br />AND/OR INDICATED ON DRAWINGS BY TRADE NAME,
<br />MANUFACTURER'S NAME OR CATALOG NUMBERS
<br />SHALL BE INTERPRETED AS ESTABLISHING A
<br />STANDARD OF QUALITY AND DESIGN. EQUAL TO
<br />THAT SPECIFIED. SUBSTITUTIONS SHALL NOT BE
<br />ALLOWED UNLESS THEY ARE SUBMITTED FOR REVIEW
<br />AN AND APPROVED BY 51D DATE.
<br />1.03 WORK BY OTHERS
<br />A. THE FOLLOWING SYSTEMS AND/OR EQUIPMENT ARE
<br />NOT A PART OF THIS SECTION, BUT SHALL BE
<br />PROPERLY CONNECTED WITH ALL PLUMBING
<br />SERVICES:
<br />- ELECTRICAL POWER WIRING BY ELECTRICAL
<br />SUB -CONTRACTOR
<br />1j04 SHOP DRAWINGS
<br />A. FURBISH SIX (6) COPIES OF SHOP DRAWING OF
<br />EQUIPMENT AND FIXTURES FOR APPROVAL PRIOR
<br />TO PURCHASING.
<br />1D5 RECORD DRAWINGS
<br />A. AFTER COMPLETION OF ALL WORK, THE PLUMBING
<br />CONTRACTOR SHALL PROVIDE THE OWNER,
<br />ENGINEER, AND ARCHITECT WITH AS BUILT RECORD
<br />DRAWINGS AS OUTLINED IN SPECIFICATIONS.
<br />PART 2 - INSTALLATION
<br />2.01 MATERIAL
<br />A. SOIL, WASTE, t VENT PIPING DRAINAGE PIPING:
<br />ABOVE FLOOR AND BELOW SLAB SHALL BE
<br />PVC-DWV SCHEDULE 40 PIPE AND FITTINGS WITH
<br />SOLVENT WELD JOINTS AND DRAINAGE PATTERN
<br />FITTINGS.
<br />B. DOMESTIC WATER PIPING:
<br />INTERIOR COLD, t HOT WATER PIPING ABOVE SLAB:
<br />SHALL BE SCHEDULE 40 CPVC PLASTIC PIPING WITH
<br />SOLVENT WELD JOINTS.
<br />C. PIPE INSULATIONS:
<br />HOT WATER SUPPLY PIPING SHALL BE INSULATED
<br />WITH 1" THICK FIBERGLASS OR EQUAL INSULATION
<br />WITH
<br />VAPOR JACKET, IN COMPLIANCE WITH APPLICABLE
<br />ENERGY CODES.
<br />2.02 VALVES
<br />A. EQUAL TO NIBCO, CRANE, OR WALWORTH. ALL
<br />BRONZE 150 LB. FULL PORT BALL VALVES.
<br />2.03 SPECIALTIES
<br />A. PIPE PROTECTIVE COAT►l %: FOR STEEL OR
<br />COPPER PIPE, PERMACEL OR SCOTHWRAP VINYL
<br />TAPE APPLIED OVER PIPE TO A TOTAL MINIMUM
<br />THICKNESS OF 20 MLS. APPLY TO ALL WATER PIPE
<br />IN CONTACT WITH MASONRY OR CONCRETE.
<br />B. PIPE HANGERS: HANGERS FOR BARE COPPER PIPE
<br />THROUGH 4 INCH (4") DIAMETER OR SMALLER SHALL
<br />BE ADJUSTABLE RING TYPE, PLASTIC COATED
<br />EQUAL TO MICHIGAN 102a, FOR STEEL PIPE MICHIGAN
<br />100.
<br />C. DRAINS AND CLEANOUTS: SEE SCHEDULE ON
<br />DRAWINGS.
<br />D. DIELECTRIC UNIONS: EBCO OR CAPITOL AT ALL
<br />POINTS OF CONNECTION BETWEEN DISSIMILAR PIPE
<br />METALS.
<br />E. FLASHING AND VENT STACKS: ALL VENTS EXTENDING
<br />THROUGH THE ROOF SHALL BE PROVIDED WITH
<br />FOUR POUND SHEET LEAD FLASHING EXTENDING
<br />UPWARD AROUND THE PIPE AND TURNED DOWN
<br />INSIDE THE PIPE OR AS OTHERWISE SHOWN ON THE
<br />DRAWINGS. THE ROOF FLASHING SHALL BE
<br />INSTALLED BY LICENSED ROOFING CONTRACTOR
<br />F. WATER HAMMER ARRESTORS. AT EACH FIXTURE, A
<br />GROUP PROVIDES "SA" AS SPECIFIED IN
<br />SPECIALTIES SCHEDULE AND ELSEWHERE AS
<br />REQUIRED, AND IN ALL CONNECTIONS TO EQUIPMENT
<br />WITH SOLENOID VALVE INSTALLED ON WATER
<br />SUPPLY LINE. WATER HAMMER ARRESTORS SHALL
<br />BE SIZED AND INSTALLED AS PER MANUFACTURER'S
<br />RECOMMENDATIONS AND PDI REQUIREMENTS FOR
<br />PREVENTION OF WATER HAMMER
<br />G. ESCUTCHEONS AND SLEEVES. WHERE PIPES PIERCE
<br />EXPOSED PARTITIONS, FLOORS, WALL, OR CEILINGS,
<br />PROVIDE CHROME PLATED ESCUTCHEONS TO THE
<br />COVER THE RAW EDGE.
<br />H. SLEEVES SHALL BE PROVIDED AT ALL PIPE
<br />PENETRATIONS OF MASONRY AND CONCRETE WALLS
<br />AND FLOORS.
<br />I. PROVIDE UL LISTED FIRE STOPPING PIPE
<br />PENETRATION ASSEMBLIES AT ALL PIPING THROUGH
<br />RATED WALLS AND ASSEMBLIES.
<br />PART 3 - EXECUTION
<br />3.01 INSTALLATION
<br />A. INSTALL PIPE ABOVE GROUND PLUMB AND SQUARE
<br />WITH BUILDING LINES, ADEQUATELY SUPPORTED
<br />WITHOUT SAGS OR HIGH POINTS. CONCEAL PIPING IN
<br />OCCUPIED AREAS AND MAINTAIN HEAD ROOM AND
<br />ACCESS SPACE IN UNFINISHED AREAS. SLEEVE
<br />PIPING THROUGH ALL WALLS, SLABS, OR PARTITIONS
<br />WITH ESCUTCHEONS AT ALL FINISHED SURFACE.
<br />PROVIDE UNIONS AT ALL FINAL CONNECTIONS AND
<br />STOPS ON ALL SUPPLIES. ALL PIPE OPENINGS SHALL
<br />BE PLUGGED DURING INSTALLATION.
<br />B. SANITARY DRAINAGE PIPING 4" t LARGER SHALL BE
<br />INSTALLED WITH A MINIMUM 1/8" PER FOOT SLOPE
<br />UNLESS NOTED OTHERWISE. ALL DRAINAGE PIPING 3"
<br />AND SMALLER SHALL BE INSTALLED WITH A MINIMUM
<br />OF 1/4" PITCH PER FOOT.
<br />C. ALL FIXTURES AND TRIM FOR HANDICAPPED SHALL
<br />BE INSTALLED IN COMPLIANCE WITH ADA CODE.
<br />D. INSTALL ALL PIPING TO ALLOW FOR EXPANSION.
<br />E. SEE RISER DIAGRAMS FOR ALL DRAINAGE t VENT
<br />PIPE SIZING FOR THE PLUMBING SYSTEMS. REFER TO
<br />PLUMBING FLOOR PLAN (WATER SYSTEM) t
<br />SCHEDULES FOR ALL WATER PIPING SYSTEM SIZING.
<br />F. ALL EXPOSED TO VIEW PIPING AND FITTINGS SHALL
<br />BE POLISHED CHROME FINISH.
<br />G. ALL WORK ASSOCIATED WITH HANDICAPPED TOILETS SHALL
<br />COMPLY WITH ADA REQUIREMENTS AND FLORIDA BUILDING
<br />CODE - CHAPTER 11 FLORIDA ACCESSIBILITY CODE FOR
<br />BUILDING CONSTRUCTION.
<br />H. FINAL CONNECTIONS TO DRAINAGE AND WATER
<br />SERVICE LINES TO EXISTING OR NEW AT 5-07FROM
<br />THE BUILDING WALLS SHALL BE BY THE PLUMBING
<br />CONTRACTOR
<br />3.02 DISINFECTING OF POTABLE WATER SYSTEM
<br />A. THE SYSTEM SHALL BE FILLED WITH A SOLUTION
<br />CONTAINING 50 PARTS PER MILLION OF AVAILABLE
<br />CHLORINE AND ALL ALLOWED TO STAND 24 HOURS
<br />BEFORE FLUSHING AND RETURNING TO SERVICE.
<br />DISINFECTION PROCEDURE AND RESULT SHALL BE
<br />SUBJECT TO THE APPROVAL OF THE LOCAL
<br />PLUMBING INSPECTOR
<br />3.03 TEST
<br />A. ALL PLUMBING SYSTEMS SHALL BE TESTED IN
<br />ACCORDANCE WITH THE FLORIDA BUILDING CODE
<br />PLUMBING. ALL TESTS SHALL BE APPROVED BY THE
<br />LOCAL PLUMBING INSPECTOR AND SHALL BE
<br />OBSERVED BY A REPRESENTATIVE OF THE
<br />ARCHITECT.
<br />3.04 SYSTEM IDENTIFICATION
<br />A. THE PLUMBING CONTRACTOR SHALL PROVIDE
<br />IDENTIFICATION TAGS FOR ALL NEW PIPING AND
<br />VALVES IN THE BUILDING AS PER OWNER ACCEPTED
<br />STANDARDS, THE PIPE MARKS SHALL INCLUDE
<br />PIPING SYSTEM IDENTIFICATION AND DIRECTIONS OF
<br />FLOW. EVERY 10 FEET AND CHANGED OF: DIRECTION.
<br />3D5 SPECIFICATIONS AND DRAWINGS
<br />A. PLUMBING CONTRACTOR SHALL FURBISH AND INSTALL
<br />COMPLETE SANITARY, STORM, AND DOMESTIC WATER
<br />PIPING SYSTEMS: INCLUDING ALL ASSOCIATED
<br />DEVICES, EQUIPMENT, CONTROLS, AND CONNECTIONS
<br />TO NEW SERVICES, SUPPORTS, AND HARDWARE
<br />REQUIRED FOR THE SATISFACTORY OPERATIONS OF
<br />THE SYSTEMS, WHETHER SPECIFICALLY SHOWN OR
<br />NOT ON THE DRAWINGS.
<br />B. THE PLANS SHOW THE LOCATION OF ALL FIXTURES
<br />AND EQUIPMENT AND ARE INTENDED TO DEPICT THE
<br />GENERAL INTENT OF THE WORK IN SCOPE, LAYOUT,
<br />AND QUALITY OF WORKMANSHIP. THEY ARE NOT
<br />INTENDED TO SHOW IN MINUTE DETAIL EVERY AND
<br />ALL ACCESSORIES INTENDED FOR THE PURPOSE OF
<br />EXECUTION OF THE WORK, BUT IT SHALL BE
<br />UNDERSTOOD THAT SUCH DETAILS WILL BE PART or -
<br />THIS WORK.
<br />C. WHERE DRAWINGS AND SPECIFICATIONS CONFLICT, IT
<br />SHALL BE THE RESPONSIBILITY OF THIS
<br />CONTRACTOR TO BRING SUCH CONFLICT TO THE
<br />ATTENTION OF THE ENGINEER FOR CLARIFICATION.
<br />D. REFER TO ARCHITECTURAL DRAWINGS AND VERIFY
<br />FIELD CONDITION FOR EXACT LOCATION OF ALL
<br />PLUMBING FIXTURES.
<br />E. CONTRACTOR SHALL KEEP A RECORD OF THE
<br />LOCATIONS OF ALL CONCEALED WORK AND UPON
<br />COMPLETION OF THE JOB, SHALL SUPPLY AS -BUILT
<br />DRAWINGS SHOWING IN COLORED PENCIL ON BLACK
<br />LINE PRINTS ANY DEVIATION FROM THE ORIGINAL
<br />DRAWINGS. THESE DRAWINGS SHALL INDICATE
<br />DIMENSION OF BURIED UTILITY LINES FROM BUILDING
<br />WALLS.
<br />F. ALL DOCUMENTS, TEST REPORT'S, t AS -BUILT
<br />DRAWINGS SHALL BE ATTACHED TO THE CLOSING
<br />DOCUMENTS OF THE PROJECT.
<br />3.06 WARRANTY
<br />A. THE PLUMBING CONTRACTOR SHALL WARRANT HIS WORK
<br />TO BE FREE FROM DEFECTS IN MATERIALS AND
<br />WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
<br />FINAL ACCEPTANCE OF ALL WORK
<br />3.01 COORDINATION
<br />A. GENERAL CONTRACTOR SHALL PROVIDE SHOP
<br />DRAWING COORDINATING ALL TRADES AND EXISTING
<br />OBSTACLES PRIOR TO STARTING CONSTRUCTION.
<br />B. VERIFY LOCATIONS, SIZES, AND INVERT ELEVATIONS OF
<br />SANITARY DRAIN, AND DOMESTIC WATER PIPING
<br />CONNECTIONS WITH FIELD CONDITIONS AND CIVIL
<br />ENGINEERING DRAWINGS PRIOR TO PROCEEDING WITH
<br />THE INSTALLATION OF ANY NEW WORK. SHALL ANY
<br />DISCREPANCIES BE DISCOVERED CONTRACTORS
<br />SHOULD OBTAIN DIRECTION FROM THE ENGINEER
<br />BEFORE PROCEEDING.
<br />C. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR WALL AND
<br />PARTITION CONSTRUCTION AND THICKNESS WHERE PLUMBING
<br />PIPING, FIXTURES CARRIERS OR EQUIPMENT IS INDICATED.
<br />BEFORE STARTING CONSTRUCTION. IDENTIFY ANY CONFLICT
<br />PRIOR TO STARTING CONSTRUCTION.
<br />D. COORDINATE EXACT LOCATION, ELEVATIONS, AND SIZES OF ALL
<br />SLEEVES IN NEW STRUCTURE WITH. STRUCTURAL AND
<br />ARCHITECTURAL DRAWINGS AND FIELD CONDITIONS.
<br />3.08 PERMITS
<br />A. PLUMBING CONTRACTOR SHALL OBTAIN ALL NECESSARY
<br />PERMITS AT HIS EXPENSE.
<br />B. THE PLUMBING CONTRACTOR SHALL VERIFY THESE DRAWINGS
<br />WITH EXISTING FIELD CONDITIONS AND SHALL COORDINATE WITH
<br />CIVIL ENGINEER LOCATIONS AND ELEVATIONS OF PLUMBING
<br />SERVICE LINES BEFORE PROCEEDING WITH CONSTRUCTION. THE
<br />WATER AND SEWER SERVICE LINES SHOWN ON THE DRAWINGS
<br />ARC FOR IREFERENCE AND BUILDING PERMIT ONLY. REFER TO
<br />CIVIL ENGINEERS DRAWING AND VERIFY FIELD CONDITIONS FOR
<br />DRAINAGE AND WATER SERVICE LINES LAYOUT AND DETAILS.
<br />C. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER
<br />IMMEDIATELY IF ANY OF THE WORK INDICATED IN THE CONTRACT
<br />DOCUMENTS CANNOT BE PERFORMED DUE TO EXISTING FIELD
<br />CONDITIONS.
<br />D. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL
<br />COMPLETE SANITARY AND DOMESTIC WATER PIPING SYSTEMS:
<br />INCLUDING ALL ASSOCIATED DEVICES, EQUIPMENT, CONTROLS,
<br />AND CONNECTIONS TO EXISTING SERVICES, SUPPORTS, AND
<br />HARDWARE REQUIRED FOR THE SATISFACTORY OPERATION OF
<br />THE SYSTEMS.
<br />E. PLUMBING CONTRACTOR SHALL PROVIDE ROUTING AND OFFSETS
<br />NECESSARY TO AVOID CONFLICT WITH STRUCTURE, FINISHES, AND
<br />WORK OF OTHER TRADES.
<br />F. WALL AND PARTITION CONSTRUCTION AND THICKNESS FOR
<br />PLUMBING PIPING OR EQUIPMENT IS INDICATED SHALL BE AS
<br />PER EQUIPMENT MANUFACTURERS SHOP DRAWINGS AND ANY
<br />CONFLICT SHALL BE IDENTIFIED PRIOR TO STARING
<br />CONSTRUCTION.
<br />G. COORDINATE EXACT LOCATION, SIZE, AND ELEVATIONS OF PIPE
<br />SLEEVES IN EXISTING STRUCTURE WITH STRUCTURAL. ENGINEER
<br />H, THE LOCATION AND ELEVATION OF PLUMBING PIPING AT CEILING,
<br />WALLS, AND BELOW SLAB FOR OWNER FURBISHED, CONTRACTOR
<br />INSTALLED EQUIPMENT IS SHOWN AS PER EQUIPMENT DATA
<br />SHEETS. THE CONTRACTOR SHALL PROVIDE PLUMBING
<br />ROUGH -INS AS PER OWNERS PROVIDED FINAL.
<br />PLUi' 6IW.s FI>CTI,IIRE 604EDULE
<br />MARK
<br />FIXTURE
<br />SOIL/
<br />WASTE
<br />VENT
<br />COLD
<br />WATER
<br />HOT
<br />WATER
<br />MANUFACTURER/
<br />MODEL
<br />DESCRIPTION
<br />EWC-IH
<br />ELECTRIC WATER
<br />2"
<br />2"
<br />1/2"
<br />-
<br />ELKAY
<br />-ELKAY, BARRIER -FREE COOLER, WATERSENTRY VIl FILTER SYSTEM, WALL MOUNTED TWO
<br />COOLER FOR H/C
<br />• LZSTLBC
<br />LEVEL WHEELCHAIR ACCESS, ONE PIECE STAINLESS STEEL BASIN EACH COOLER WITH
<br />INTEGRAL DRAIN GRID, t BUBBLER HEAVY-DUTY STEEL FRAME, LED -FREE CARRIER
<br />SUPPORTED FROM FLOOR (WITHSTANDING 2500 OF LOAD APPLIED ON THE FRONT OF
<br />THE FIXTURE), 115V, 601-1Z, SINGLE PHASE.
<br />ELKAY
<br />-ACCESSORY CANE APRON, THEWO-FORMED ABS PLASTIC.
<br />0 LKAPREZL
<br />ZURN M Z-1225-51-
<br />-WATER COOLER SUPPORT SYSTEM WITH TOP AND BOTTOM PLATES.
<br />COMPLETE WITH DURA-COATED RECTANGLER STEEL UPRIGHTS WITH
<br />WELDED FEET, ADJUSTABLE SUPPORT, PLATES, AND MOUNTING FASTENERS.
<br />MSB_I
<br />MOP SERVICE BASIN
<br />3"
<br />2"
<br />1/2"
<br />1/2"
<br />FIAT "TS15-300
<br />-PRE CAST TERRAZZO, FLOOR MOUNTED 32"X32"Xl2" MOP SERVICE BASIN,
<br />STRAINER 01453-515
<br />WITH STAINLESS STEEL CAPS ON ALL CURBS
<br />MOP BRACKET: '888-CC
<br />-SERVICE SINK FAUCET, 5-3/5" C-C RIGID CAST BRASS VACUUM BREAKER SPOUT WITH
<br />VINYL BUMPER
<br />3/4" MALE HOSE THREAD OUTLET, 2-3/8" METAL LEVER HANDLES, QUATURN OPERATING
<br />GUARD OE-11-AA
<br />CARTRIDGES.
<br />CHICAGO
<br />540-LD897SWXFCP
<br />L-1H
<br />LAVATORY
<br />2"
<br />2"
<br />1/2"
<br />1/2"
<br />AMERICAN STANDARD
<br />-M-1/4" X 15-3/4" ROUND VITREOUS CHINA, UNDERCOUNTER MOUNTED, 4" FAUCET
<br />UNDERCOUNTER
<br />05462.000
<br />CENTERS, REAR OVERFLOW, UNGLAZED RIM, SELF -RIMMING, FRONT OVERFLOW.
<br />MOUNTED SINK
<br />CHICAGO
<br />-ELECTRONIC LAVATORY FAUCET, DECK MOUNTED, 4" CENTERS, 5-3/8" C-C SPOUT,
<br />SENSOR TYPE
<br />0116 .106AB.1
<br />OB GPM VANDAL RESISTANT SPRAY OUTLET, 12 VOLT AC TRANSFORMER
<br />-PROVIDE OPTIONAL THERMOSTATIC MIXING VALVE, t PLUG-IN TRANSFORMER -
<br />SINGLE USE FOR ELECTRONIC LAVATORY FAUCET ABOVE.
<br />DRAIN t SUPPLIES:
<br />-(SEE NOTES 01, 2, 3 t 4)
<br />WATER CLOSET FLOOR
<br />4"
<br />2"
<br />1"
<br />-
<br />AMERICAN STANDARD
<br />-FLOOR MOUNTED FLUSHOMETER VALVE TOILET, VITREOUS CHINA, LOW
<br />MOUNTED FLUSH VALVE
<br />03461AP0
<br />CONSUMPTION 1.6 GPF, EVERCLEAN SURFACE, 10" ROUGH -IN, 16-1/2" RIM HEIGHT,
<br />FOR H/C SENSOR TYPE
<br />ELONGATED BOWL, SIPHON JET ACTION FLUSH, FULLY GLAZED 2-1/8" TRAPWAY,
<br />TOP SPUD, WHITE.
<br />SLOAN ROYAL
<br />-EXPOSED, SENSOR WATER CLOSET FLUSHOMETER, CHROME PLATED, P I.P.S.
<br />0111-116 ES-6
<br />SCREWDRIVER BAK-CHEK, ADJUSTABLE TAIL PIECE.
<br />OLSONITE 0135SS SEAT
<br />-WHITE OPEN FRONT SEAT LESS COVER
<br />SINGLE BOWL SINK
<br />2"
<br />2"
<br />1/2"
<br />1/2"
<br />ELKAY * LR-1116
<br />-11" x 16" SINK, COUNTERTOP, SINGLE COMPARTMENT, SELF
<br />SENSOR TYPE
<br />RIM, 0302 STAINLESS STEEL W/DROP LEDGE. SINGLE HOLE PUNCH
<br />CHICAGO
<br />-ELECTRONIC GOOSENECK FAUCET, DECK MOUNTED, SINGLE HOLE, POLISHED
<br />0116.428A5.1
<br />CHROME FINISH, 5-1/4" C-C RIGID/SWING GOOSENECK SPOUT, 1.5 GPM LAMINAR FLOW
<br />CONTROL DEVICE AT SPOUT INLET, 12 VOLT AC TRANSFORMER
<br />-PROVIDE OPTIONAL PLUG-N TRANSFORMER- SINGLE USE FOR ELECTRONIC
<br />GOOSENECK FAUCET ABOVE.
<br />ELKAY
<br />-POLISHED CHROME PLATED STAMPED BRASS GRID DRAIN, 1-1/2" TAILPIECE,
<br />OLK-18
<br />"P" TRAP, STOP VALVES AND SUPPLIES (SEE NOTES *I, 2 t 3)
<br />;z
<br />SINGLE BOWL SINK
<br />2"
<br />2"
<br />1/2"
<br />1/2"
<br />ELKAY OLR221S
<br />-25" x 21-1/4" SINK, COUNTERTOP, SINGLE COMPARTMENT 0302
<br />SENSOR TYPE
<br />STAINLESS STEEL WITH DROP LEDGE. SINGLE HOLE PUNCH
<br />CHICAGO
<br />-ELECTRONIC GOOSENECK FAUCET, DECK MOUNTED, SINGLE HOLE, POLISHED
<br />$116.428A13.1
<br />CHROME FINISH, 5-1/4" C-C RIGID/SWING GOOSENECK SPOUT, IB GPM LAMINAR FLOW
<br />CONTROL DEVICE AT SPOUT INLET, 12 VOLT AC TRANSFORMER
<br />-PROVIDE OPTIONAL PLUG-IN TRANSFORMER- SINGLE USE FOR ELECTRONIC
<br />GOOSENECK FAUCET ABOVE.
<br />ELKAY
<br />-POLISHED CHROME PLATED STAMPED BRASS GRID DRAIN, 1-1/2" TAILPIECE,
<br />°LK-18
<br />"P" TRAP, STOP VALVES AND SUPPLIES (SEE NOTES 01, 2 t 3)
<br />8 3
<br />SINGLE BOWL SINK
<br />2"
<br />2"
<br />1/2"
<br />1/2"
<br />ELKAY OLR221S
<br />-25" x 21-1/4" SINK, COUNTERTOP, SINGLE COMPARTMENT 0302
<br />STAINLESS STEEL WITH DROP LEDGE. SINGLE HOLE PUNCH
<br />AMERICAN STANDARD
<br />-SINGLE LEVER KITCHEN FAUCET, S-1/4" SWIVEL CAST BRASS SPOUT, ADJUSTABLE HOT
<br />0420SAW
<br />LIMIT SAFETY STOP, 2.2 GPM., METAL ESCUTCHEON PLATE.
<br />ELKAY
<br />-POLISHED CHROME PLATED STAMPED BRASS GRID DRAIN, 1-1/2" TAILPIECE,
<br />°LK-18
<br />"P" TRAP, STOP VALVES AND SUPPLIES (SEE NOTES 01, 2 t 3)
<br />EWU-1
<br />EYE WASH UNIT
<br />1-1/2"
<br />1-1/2"
<br />1/2"
<br />-
<br />BRADLEY
<br />-DECK-MOUNTED EYEWASH UNIT, 10-3/4" DIA. BOWL CORROSION RESISTANT
<br />DECK MOUNTED
<br />0819-230DT
<br />STAINLESS STEEL, CHROME -PLATED BRASS SPRAY14EAD ASSEMBLY W/ SOFT
<br />FLOW EYEWASH HEADS AND PROTECTIVE SPRAYHEAD COVERS, CHROME -PLATED
<br />BRASS 1/2" STAY -OPEN BALL VALVE, GALVANIZED STEEL PROTECTED W/
<br />BRAOTECT SAFETY YELLOW COATING. 1-1/4" DRAIN FITTING FURNISHED.
<br />[C'L
<br />ICE MAKER
<br />-
<br />-
<br />3/8"
<br />-
<br />SPECIALTY PRODUCTS
<br />-PLASTIC ICE MAKER VALVE BOX, 6-13/16" X 4-1/8" DIMENSION.
<br />VALVE BOX
<br />005-801
<br />WATTS 5-YR
<br />-IN LINE WATER FILTER
<br />DW--1
<br />DISH WASHER
<br />-
<br />-
<br />-
<br />1/2"
<br />PROVIDE BY
<br />-DISHWASHER MACHINE PROVIDED BY OWNER CONTRACTOR TO ROUGH -IN FOR <
<br />MACHINE
<br />OWNER
<br />MAKE FINAL CONNECTIONS.
<br />NOTES:
<br />I. LAVATORY, SINKS t WATER COOLERS SUPPLY SHALL BE BRASS W/ BRASS ANGLE STOPS FOR Vs" WATER SUPPLY LINES, W/ LOOSE KEY (W/CAP),
<br />AND WALL FLANGE. ALL COMPONENTS SHALL BE POLISHED CHROME FINISH. MANUFACTURER: E.BC., INC. OR APPROVED EQUAL.
<br />2. CAST BODY "P" TRAP 1-1/2" x 1-1/2" WITH HEAVY CAST J-BEND t FLAT CLEANOUT PLUG, SLIP NUTS AND WALL FLANGE. ALL COMPONENTS SHALL BE POLISHED
<br />CHROME FINISH. MANUFACTURER: E.BC., INC. OR APPROVED EQUAL.
<br />3. STRAINERS SHALL BE FURNISHED W/FIXTURES. FOR H/C FIXTURES PROVIDE OFFSET TAILPIECE.
<br />4. PROVIDE TRUEBRO MODEL 103 (WHITE), ANTIMICR05AL HANOI LAV-GUARDS INSTALLATION KIT FOR ALL WHEELCHAIR LAVATORY t SNKS FOR WATER SUPPLIES t WASTE LINE.
<br />5. ALL PLUMBING FIXTURES t TRIM SHALL BE APPROVED BY THE OWNER BEFORE FINAL ORDER IS MADE.
<br />SiO-5or-MECIALTIES SCI-I DUL
<br />MARK
<br />DESCRIPTION/LOCATION
<br />MANUF.
<br />CAT. NUMBER
<br />GENERAL NOTES
<br />1 r,O
<br />WALL CLEANOUT
<br />ZURN
<br />ZN-1446
<br />ROUND ACCESS COVER
<br />GcQ
<br />GRADE CLEANOUT
<br />ZURN
<br />Z-1414-Z5
<br />HEAVY DUTY, DURA COATED, SCORIATED COVER
<br />SA
<br />W. HAMMER ARRESTOR
<br />ZURN
<br />Z-1100 SHOKTROL
<br />SIZE FOR 3/4" t P PIPE.
<br />yg
<br />VACUUM RELIEF VALVE
<br />WATTS
<br />N36-Ml
<br />ALL BRASS BODY (INSTALL A MINIMUM
<br />OF 6" ABOVE WATER HEATER)
<br />EP-
<br />FLOOR DRAIN
<br />ZURN
<br />Z-415-ZN-P
<br />S" 0 TYPE "B" STRAINER MEMBR CLAMP.
<br />H�
<br />HOSE BIBS
<br />WOODFORD
<br />24P-3/4
<br />POLISHED CHROME FINISH W/VACUUM BREAKER
<br />_Q2
<br />GARBAGE DISPOSER
<br />IN-SINK-ERATOR
<br />BADGER 5
<br />1/2 HP, PLASTIC GRIND CHAMBER CONTINUOUS FEED, GALVANIZED STEEL
<br />GRINDING ELEMENTS WITH TWO STAINLESS SWIVEL LUGS, SELF-SERVICE
<br />WRENCH, 120/1/60.
<br />PT
<br />PLASTER TRAP
<br />J.R. SMITH
<br />811OT-ARIO
<br />WHITE DUCO COATED CAST IRON BODY AND ALUMINUM GASKETED COVER AND
<br />SEDIMENT STRAINER WITH REMOVABLE STAINLESS STEEL SCREEN. ACID
<br />RESISTANT COATING INSIDE AND OUTSIDE. PROVIDE MINIMUM OF S 1/4" SPACE
<br />ABOVE INTERCEPTOR FOR REMOVAL OF STRAINER 1 1/2" INLET/OUTLET.
<br />PLUi' S INCH SHEET INDEX
<br />PI PLUMBING SPECIFICATIONS, SCHEDULES t LEGEND
<br />P2 PLUMBING DEMOLITION FLOOR PLAN
<br />P3 PLUMBING RENOVATION FLOOR PLAN- WASTE t VENT
<br />P4 PLUMBING RENOVATION FLOOR PLAN- WATER
<br />P5 PLUMBING DETAILS
<br />Pro PLUMBING RISER DIAGRAMS
<br />PLUMING LEGEND
<br />DESCRIPTION
<br />NEW SANITARY WASTE ABOVE SLAB
<br />EXISTING SANITARY WASTE TO REMAIN
<br />EXISTING SANITARY WASTE TO BE ABANDONED
<br />NEW VENT
<br />EXISTING VENT TO REMAIN
<br />NEW COLD WATER PIPING
<br />EXISTING COLD WATER PIPING TO REMAIN
<br />NEW HOT WATER PIPING
<br />EXISTING HOT WATER PIPING TO REMAIN
<br />PIPING TO BE REMOVED
<br />NEW SHUT-OFF VALVE
<br />EXISTING PLUMBING FIXTURES TO REMAIN
<br />EXISTING PLUMBING FIXTURES TO BE REMOVED
<br />POINT OF CONNECTION TO EXISTING SYSTEM
<br />ABBREVIATIONS
<br />COLD WATER SYSTEM
<br />HOT WATER SYSTEM (120'F)
<br />INDIRECT DRAIN PIPING
<br />EXISTING
<br />FINISHED FLOOR ELEVATION.
<br />BELOW FLOOR
<br />ABOVE CEILING
<br />UNLESS OTHERWISE NOTED
<br />CIVIL ENGINEER
<br />PLUMBING CONTRACTOR
<br />GENERAL CONTRACTOR
<br />BELOW FINISH FLOOR
<br />f7Z���f-/
<br />CW
<br />HW
<br />ID
<br />EX.
<br />FFE
<br />BFL
<br />ACL
<br />U.O.N.
<br />C.E.
<br />P.C.
<br />G.C.
<br />B.F.F.
<br />CULATOR PUMP SCHEDULE
<br />DESCRIPTION
<br />MANUFACTURDEL ER
<br />G.P.M.
<br />HEAD
<br />HORSEPOWER
<br />ELECTRICAL
<br />LOCATION
<br />r,1.FU.,..
<br />20' TEMP. LOOP
<br />GRUNDFOS
<br />IB
<br />1'
<br />1/25
<br />120VAPI�/60Hz
<br />SEE PLANS
<br />RECIRC (DOMESTIC)
<br />'2P311
<br />WITH PUMP CHAMBER AND GONSTUCTION FOR DOMESTIC USES.
<br />KING PRESSURE OF 145 PAl. AND MIN. OPERATING TEMPERATURE OF 140' F.
<br />CIFICATIONS FOR ADDITIONAL REQUIREMENTS.
<br />THERMOSTATIC MIXING VALVE ASSEMMY SCr"TEMPULE
<br />MANUFACTURER
<br />MIN. FLOW
<br />MAX. FLOW CAPACITY
<br />MAX PRESSURE DROP
<br />PIPE SIZE
<br />PIPE SIZE
<br />NOTES
<br />SYMBOL
<br />t MODEL NO.
<br />G.P.M.
<br />G.P.M.
<br />P.S.I.G.
<br />INLETS
<br />OUTLET
<br />TMV-I
<br />TM-186-5015-PRY-RF-O-TC
<br />I
<br />2S
<br />10
<br />3/4"
<br />1"
<br />1,2,344
<br />NOTES
<br />I. PROVIDE PIPED ASSEMBLY WITH INLET < OUTLET SHUTOFF VALUES
<br />2. PROVIDE WALL MOUNTING BRACKET, DIAL THERMOSTAT t TEST CONNECTION ASSEMBLY.
<br />3. PROVIDE INTEGRAL STRAINER CHECKSTOPS ON INLETS, ROUGH BRONZE FINISH, LESS CABINET.
<br />4. INSTALLED AS PER MANUFACTURERS RECOMMENDATIONS.
<br />WATER rLIWEATER SCHEDULE
<br />MARK
<br />MAKE t MODEL
<br />TYPE
<br />STORAGE
<br />qJS
<br />DM
<br />( )
<br />ItC(WW
<br />AT
<br />I (MIT
<br />(BTU
<br />FLUE
<br />(
<br />TES
<br />DESCRIPTIONS
<br />KW
<br />V
<br />PH
<br />HZ
<br />E 1
<br />A.O. SMITH
<br />T _ELE.
<br />50
<br />144511
<br />3
<br />10
<br />-
<br />-
<br />(2)
<br />208
<br />1
<br />60
<br />1,2 t 3
<br />PIPE PtT RELIEF VALVE
<br />4 PAN AS PER DETAIL
<br />DEN-52
<br />W-20-I/2'
<br />6
<br />NOTES
<br />1. PROVIDE FACTORY INSTALLED CONTROLS INCLUDING T-STATS SET ON 120' F
<br />2. PROVIDE ALL REQUIRED OPTIONS TO COMPLETE THE INSTALLATION.
<br />3. INSTALL EWH-1 IN ACCORDANCE TO FLORIDA BUILDING CODE - PLUMBING, MECHANICAL
<br />t NATIONAL ELECTRIC CODES, APPLICABLE STANDARDS AND MANUFACTURERS RECOMMENDATIONS.
<br />4. WIRE FOR NON -SIMULTANEOUS ELEMENT OPERATION.
<br />5. PROVIDE A 3 YEAR WARRANTY.
<br />NSION TANK °SDUL
<br />FEXT-I
<br />ANUFACTURER
<br />t MODEL
<br />TYPE
<br />MAX. PRESS.
<br />PSI
<br />MAX OPERATING
<br />TEMP.'_
<br />TANK VOLUME
<br />GAL (TOTAL)
<br />TANK ACCEPTANCE
<br />GAL
<br />AIR PRE-C1HAWsED
<br />PSI
<br />CONNECTION SIZE
<br />TANK SIZE
<br />NOTES
<br />DIAMETER - IN
<br />LENGTH - M
<br />TTS 0 DET-5-Ml
<br />POTABLE WATER
<br />W
<br />140
<br />2.1
<br />85
<br />40
<br />3/4" MALE
<br />8-3/8"
<br />12-1/2"
<br />NOTES: 1 t 2
<br />E BRACKETS FOR TANK SUPPORT.
<br />2. TANK SHALL BE LISTED FOR POTABLE WATER INSTALLATION.
<br />REVISIONS
<br />BY
<br />�i
<br />00
<br />• .V,, m N
<br />o00
<br />_ �xti
<br />=' V
<br />N
<br />N GL G ,2
<br />�-� o c `�
<br />• N '�,
<br />� ULo
<br />it E
<br />a
<br />co 3
<br />ti
<br />�---• E a�
<br />N
<br />�-� "'
<br />1;
<br />1
<br />u i
<br />���wv]AWfi�
<br />E OEy51
<br />C L'
<br />e?�
<br />4I
<br />a
<br />r ID
<br />IV'- ®61 ®fie•
<br />10 0
<br />O _J F �¢
<br />o x > `o
<br />M ry c
<br />E
<br />U 6 m
<br />c Z c o -
<br />- o ¢ Ts
<br />w p� E
<br />E
<br />� U
<br />a)
<br />c �z
<br />� Nm
<br />> _I
<br />-a �
<br />Q - m .2
<br />00 mW
<br />w ui r, „ o
<br />-
<br />.0
<br />ul
<br />0- E N
<br />�t
<br />0 0
<br />a ¢ .z
<br />�a
<br />ms
<br />0 UC
<br />•v
<br />J I-
<br />xx-
<br />i
<br />LJ W v�
<br />U
<br />Q U) O
<br />a Uw �`'-
<br />m
<br />OO��y
<br />>�U�L
<br />O
<br />_
<br />N C-
<br />o
<br />QZLLJ
<br />00
<br />Om
<br />m J �
<br />1L.
<br />Date: 06. 12. 12
<br />Scale: AS NOTED
<br />Project Mgr: AAY
<br />Drawn:
<br />Job: 10-61
<br />Sheet
<br />p 1
<br />
|