Laserfiche WebLink
IN <br />X-RAY EQUIPMENT TYPICAL INSTALLATION 15 SHOWN <br />SEE MANUFACTURER SHOP DRAWINGS FOR ALL SITE <br />SPECIFIC REQUIREMENTS PRIOR TO ROUGH -IN <br />X-RAY EQUIPMENT/ACCESORIES BY CONTRACTOR <br />OA 100A, 3POLE, SHUNT TRIP ENCLOSED N-1 CIRCUIT BREAKER, 22,000 AIC, FLUSH MOUNTED <br />Al X-RAY IN USE WARNING LIGHT CONSULT X-RAY MANUFACTURER <br />FBI <br />© 6"X6"X4" FLUSH MOUNTED 5OX,12"AFF, PROVIDE 2" CHASE NIPPLE IN CENTER OF COVER <br />6"X6"X4" FLUSH MOUNTED 50X,36"AFF, PROVIDE 2" CHASE NIPPLE IN CENTER OF COVER <br />© 1"X12- SURFACE MOUNTED WIREWAY W/ 2 ELBOWS FOR MXR/S1 INSTALLERS <br />PROVIDE J-BOX AS DIRECTED BY MXR/SI INSTALLERS <br />4 MUSHROOM STYLE PUSHBUTTON FOR SHUNT TRIP CONTROL OF PANEL A MOUNTED IN A <br />FLUSH BACK BOX. PROVIDE PLACARD "X-RAY EMERGENCY POWER OFF" <br />HVAC UNITS DISCONNECT AND FEEDER SCHEDULE <br />UNIT ID, <br />WIRE AND CONDUIT SIZES <br />DISCONNECT <br />MOCP <br />MCA <br />RTU-1 <br />3 N 4 AND 1 OS Ewa_ - 1" C <br />100/3/10/3R <br />15 <br />42 <br />RTU-2 <br />3 N 6 AND 1 *10 E.G, - 1" C <br />60/3/45/31R, <br />45 <br />55 <br />RTU-3 <br />3 * 4 AND 1 016 ECG. - P C <br />100/3/10/3R <br />i0 <br />42 <br />RTU-4 <br />3 04 AND 108 EG_ - P C <br />60/3/60 <br />10 <br />55 <br />CU-1 <br />3 M 4 AND 1 010 E.G. - 1" C <br />60/3/60/3R <br />ro0 <br />42 <br />AHI <br />3 " 4 AND 1 010 E�G_ - P C <br />60/3/60 <br />60 <br />55 <br />- VERIFY EACH HVAC UNIT NAMEPLATE WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN <br />XfUY EQUIPMENT LEGEND CONNECTION 3C 1�ULE <br />SCALE.. NOT TO SCALE IG)—[WVAC <br />SCALE; NOT TO SCALE <br />STUB -OUT CONDUIT ABOVE <br />CEILING- PROVIDE AN <br />INSULATED THROAT <br />CONNECTOR AT END OF <br />CONDUIT <br />PROVIDE PULL WIRE FOR DATA <br />AND PHONE TECH_ <br />HARD CEILING <br />DROP CEILING <br />1) 1" EMT EMPTY CONDUIT <br />4x4x2-1/8" DEEP JUNCTION BOX V OR� <br />WITH PLASTER RING. MOUNTING <br />HEIGHT 18" ON CENTER —� <br />WALL <br />FLOOR _\ <br />IG)l COMMUNICATION OUTLET DETAIL] <br />IDI EL EGO, I 'IC POWER PLAN <br />SCALE-- 3/16" ■ I' -Oil <br />KEYED NOTES <br />I. PROVIDE FINAL CONNECTION TO XRAY EQUIPMENT. <br />COORDINATE WITH SHOP DRAWINGS FROM MFR <br />2, PROPOSED LOCATION FOR BUILDING ELECTRICAL <br />SERVICE, <br />3. LOCATE RECEPTACLE AND DATA OUTLET IN MILLWORr, <br />COORDINATE WITH CABINET INSTALLER <br />4. PROVIDE A 4' WIDE X 8' TALL PLYWOOD BACKBOARD <br />FOR TELEPHONE EQUIPMENT_ PAINT WITH 2 COATS OF FIRE <br />RETARDANT PAINT TO MATCH WALL. <br />5. PROVIDE (1) 2" CONDUIT TO THE PROPERTY LINE AS <br />DIRECTED BY TELEPHONE COMPANY_ COORDIANTE STUB <br />UP LOCATION WITH THE TELEPHONE COMPANY. STUB UP <br />AND CAP CONDUIT PROVIDE LABEL ON EACH OF <br />CONDUIT INDICATING LOCATION OF OTHER END OF <br />CONDUIT SYSTEM <br />Co- PROVIDE (1) 2" CONDUIT TO PROPERTY LINE AS <br />DIRECTED BY CATV COMPANY, STUB UP AND CAP <br />CONDUIT PROVIDE LABEL ON EACH OF CONDUIT <br />INDICATING LOCATION OF OTHER END OF CONDUIT <br />SYSTEM <br />'i_ EXTEND A 04 GEC TO THE BUILDING: GROUND <br />ELECTRODE SYSTEM. PROVIDE A GROUND BAR AT THE <br />TELEPHONE BOARD, <br />S. PROVIDE FINAL CONNECTION TO ELECTRIC WATER <br />COOLER PROVIDE CORD AND CAP IF REQUIRED OR <br />HARD WIRED CONNECTION. COORDINATE WITH PLUMBING <br />CONTRACTOR <br />S_ LOCATE MICROWAVE OUTLET IN UPPER CABINET <br />MILLWORK AS DIRECTED BY ARCHITECT AS REQUIRED <br />FOR THE BUILT-IN MICROWAVE_ COORDINATE WITH <br />MILLWORK INSTALLER <br />10_ COORDINATE EXACT HEIGHT AND LOCATION OF TV <br />OUTLET AND RECEPTACLE WITH TENANT PRIOR TO <br />ROUGH -IN <br />11_ MOUNT ELECTRICAL EQUIPMENT AT 60" TO BOTTOM_ <br />12. PROVIDE FINAL CONNECTION TO VACUUM PUMP <br />COORDINATE WITH MECHANICAL CONTRACTOR <br />13, PROVIDE FINAL CONNECTION TO MED GAS ALARM <br />PANEL. COORDINATE EXACT LOCATIONS WITH MED GAS <br />INSTALLER PROVIDE CONDUITS TO REMOTE PANELS AT <br />NURSE STATIONS. REFER TO THE MECHANICAL PLANS <br />14. PROVIDE FINAL CONNECTION TO MED GAS CONTROLLER <br />COORDINATE EXACT LOCATION WITH MED GAS <br />INSTALLER <br />15, PROVIDE FINAL CONNECTION TO GARBAGE DISPOSAL <br />16. RECEPTACLE AND DATA OUTLET FOR EMPLOYEE TIME <br />CLOCK, VERIFY EXACT LOCATIONS WITH OWNER PRIOR <br />TO ROUGH -IN <br />ii. PROVIDE FINAL CONNECTION TO UC DISHWASHER <br />GrtENEiUL NOTES <br />L BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE <br />THEMSELVES WITH EXISTING CONDITIONS AND SATISFY <br />THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. <br />THE SUBMISSION OF A BID WILL BE EVIDENCED THAT <br />SUCH AN EXAMINATION HAS BEEN MADE_ LATER CLAIMS <br />FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED, OR <br />FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE <br />BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL <br />NOT BE ALLOWED_ <br />2. ALL EXISTING CIRCUITS TO REMAIN SHALL BE <br />RECONNECTED WHETHER INDICATED OR NOT ON <br />PROJECT DOCUMENTS. <br />3. NEW AND EXISTING CIRCUIT DESIGNATIONS MAY NOT <br />REPRESENT ACTUAL FIELD CONDITIONS_ FIELD VERIFY <br />WHERE REQUIRED AND INDICATE ACTUAL CIRCUIT USED <br />ON THE AS -BUILT DRAWINGS. <br />4, COORDINATE WITH OTHER TRADES FOR ITEMS IN THEIR <br />SCOPE OF WORK WHICH WOULD REQUIRE ELECTRICAL <br />WORK (DISCONNECTION/RECONNECTION ETC.) AND ARE <br />NOT INDICATED ON THE ELECTRICAL PLANS. <br />5_ WHERE EXISTING PARTITIONS OR WALLS ARE SHOWN TO <br />BE REMOVED CONTRACTOR SHALL REMOVE DEVICES <br />TO NEAREST SOURCE JUNCTION BOX AND SHALL <br />MAINTAIN SERVICE TO REMAINING DOWNSTREAM <br />ELECTRICAL OUTLETS_ COORDINATE THE DEMOLITION <br />OF THE EXISTING WALLS WITH ARCHITECTURAL DRAWINGS, <br />6. PROTECT EXISTING ELECTRICAL EQUIPMENT AND <br />INSTALLATIONS NECESSARY TO REMAIN, IF DAMAGED <br />OR DISTURBED IN THE COURSE OF THE WORK, REMOVE <br />DAMAGED PORTIONS AND INSTALL NEW PRODUCTS OF <br />EQUAL CAPACITY, QUALITY, AND FUNCTIONALITY. <br />i_ REMOVE ELECTRICAL EQUIPMENT AND INSTALLATIONS, <br />INDICATED TO BE DEMOLISHED, IN THEIR ENTIRETY_ <br />WHERE THE EXISTING EQUIPMENT INDICATED TO BE <br />DEMOLISHED CONTAINS BRANCH CIRCUITRY SERVICING <br />OUTLETS THAT ARE EXISTING TO REMAIN, RELOCATE THE <br />BRANCH CIRCUIT TO AN ALTERNATE PANEL AND <br />INDICATE THE CHANGE ON THE AS -BUILT DRAWINGS, <br />8. ABANDONED WORK CUT OR REMOVE RACEWAY <br />SLEEVES AND WIRING, INDICATED TO BE ABANDONED IN <br />PLACE, BELOW THE SURFACE OF ADJACENT <br />CONSTRUCTION_ CAP RACEWAYS AND PATCH SURFACE <br />TO MATCH EXISTING FINISH. <br />S_ THE CONTRACTOR SHALL INCLUDE WITHIN THE BID ALL <br />REQUIRED OFF HOUR, OVERTIME, AND NON -BUSINESS <br />HOUR WORK AS REQUIRED TO PERFORM THE <br />DEMOLITION WITHOUT DISRUPTING THE BUILDING TENANTS <br />NORMAL BUSINESS OPERATIONS_ <br />10. ALL DEMOLISHED EQUIPMENT AND WIRING SHALL BE <br />REMOVED FROM SITE AND PROPERLY DISPOSED OF, <br />OR TURNED OVER TO THE OWNER AT THE OWNER'S SOLE <br />OPTION_ <br />11_ COORDINATE THE EXACT LOCATIONS AND MOUNTING <br />HEIGHTS OF RECEPTACLES, VOICEMATA OUTLETS AND <br />ALL OTHER ELECTRICAL DEVICES WITH THE OWNER <br />PRIOR TO ROUGH -IN, <br />REVISIONS BY <br />00 <br />�00 <br />Q4.00 <br />►�-� p 0 h E <br />U ro ti U <br />C RU <br />d o <br />oxti . <br />ua <br />N <br />m <br />it <br />w <br />a <br />4 <br />Y �'N <br />h h <br />N Y <br />Z Z to h <br />CA <br />J � <br />w <br />i <br />O_ —� <br />• Z LLJ <br />a _I H <br />Z N <br />W UW a� <br />-p J V C:r <br />c < va c <br />a C) W LL— <br />c a� <br />00Q� <br />1- W v •- <br />o C) <br />O <br />a <br />� �Z C0pN <br />_WM <br />C E2 <br />0 W <br />':) J :=) <br />m L L_ <br />Date: 06. 12. 12 <br />Scale: AS NOTED <br />Project Mgr: MY <br />Drawn: WR <br />Job: 10-61 <br />Sheet <br />E2 <br />