GENERAL NOTES & SPECIFICATIONS
<br />1
<br />A 1 2
<br />REFLECTED CEILING PLAN
<br />SCALD 1/41 = 1'-0'
<br />01
<br />DIMIISO� NNWE- EltilIHES
<br />ACOUSTICAL TILE CEILING SYSTEMS
<br />1. INSTALL SUSPENSION SYSTEM AND PANELS IN ACCORDANCE WITH THE MANUFACTURER'S
<br />INSTRUCTIONS, AND IN COMPLIANCE WITH ASTM C 636 AND WITH THE AUTHORITIES
<br />HAVING JURISDICTION.
<br />2. SUSPEND MAIN BEAM FROM OVERHEAD CONSTRUCTION WITH HANGER WIRES SPACED
<br />4'-0' ON CENTER ALONG THE LENGTH OF THE MAIN RUNNER, INSTALL HANGER WIRES
<br />PLUMB AND STRAIGHT,
<br />3, INSTALL WALL MOLDINGS AT INTERSECTION OF SUSPENDED CEILING AND VERTICAL
<br />SURFACES, MITER CORNERS WHERE WALL MOLDINGS INTERSECT OR INSTALL CORNER
<br />CAPS.
<br />4, FOR REVEAL EDGE PANELS+ CUT AND REVEAL OR RABBET EDGES OF CEILING PANELS
<br />AT BORDER AREAS AND VERTICAL SURFACES,
<br />5. INSTALL ACOUSTICAL PANELS IN C❑ORDINATION WITH SUSPENDED SYSTEM, WITH EDGES
<br />RESTING ON FLANGES OF MAIN RUNNER AND CROSS TEES. CUT AND FIT PANELS
<br />NEATLY AGAINST ABUTTING SURFACES. SUPPORT EDGES BY WALL MOLDINGS.
<br />6. ACOUSTICAL TILE SUPPORT - WHENEVER ITEMS SUCH AS SMOKE_ DETECTORS, SIGNAGE,
<br />SPEAKERS, ETC, ARE ATTACHED TO CEILING TILES, PROVIDE CROSS BRACE SUPPORT
<br />SECURED TO EACH SIDE OF ITEM, BRACE SHALL BE LOCATED TO PROVIDE FULL
<br />SUPPORT OF ITEM INDEPENDENTLY OF TILE WITHOUT ANY SAG, BOW OR TWIST OF
<br />CEILING OR GRID.
<br />GYPSUM BOARD MATERIALS
<br />1. PROVIDE 5/8' REGULAR GYPSUM BOARD, 5/8' TYPE 'X' FIRE -RATED GYPSUM B13ARD
<br />AND 5/8' WATER-RESISTANT GYPSUM BACKING BOARD AS INDICATED IN THE DRAWINGS
<br />AND COMPLYING WITH ASTM C 1396, BOARD SIZE AS SUITABLE FOR USE TO MINIMIZE
<br />JOINTS.
<br />2, ALL GYPSUM DRYWALL TO BE TAPED, SPACKLED AND SANDED SMOOTH PRIOR TO
<br />PAINTING. COMPLY WITH ASTM C 754 FOR INSTALLATION AND FINISHING PROCEDURES,
<br />ACOUSTICAL TREATMENT
<br />1. SOUND -ATTENUATION BLANKETSi ASTM C 665, TYPE I BLANKETS WITHOUT MEMBRANE
<br />FACING, FIRE -RATED AS REQUIRED BY ASSEMBLY,
<br />2. ACOUSTICAL SEALANTt NON -HARDENING, NON-DRYING, NON -SKINNING, NON -STAINING,
<br />NON -BLEEDING, GUNNABLE TYPE AS RECOMMENDED BY MANUFACTURER FOR USE IN
<br />CONJUNCTION WITH GYPSUM BOARD,
<br />PAINTING
<br />1. PAINT ALL EXPOSED SURFACES UNLESS
<br />OTHERWISE INDICATED.
<br />2. EXTERIOR
<br />PAINT SCHEDULE
<br />CONCRETE,
<br />STUCCO AND MASONRY,
<br />1
<br />COAT ACRYLIC LATEX PRIMER
<br />2
<br />COATS FLAT ACRYLIC LATEX
<br />EXTERIOR
<br />ALUMINUMi
<br />1
<br />COAT ZINC CHROMATE PRIMER
<br />2
<br />COATS FLAT ALKYD ENAMEL
<br />EXTERIOR
<br />WOOD TRIM,
<br />1
<br />COAT ACRYLIC LATEX PRIMER
<br />2
<br />COATS FLAT ACRYLIC LATEX
<br />EXTERIOR
<br />STEEL & FERROUS M%,
<br />2
<br />COATS RUST INHIBITIVE WATER BASED PRIMER
<br />2
<br />COATS EXTERIOR LATEX
<br />3, INTERIOR
<br />PAINT SCHEDULE
<br />CONCRETE
<br />AND MASONRY,
<br />1
<br />COAT BLOCK FILLER
<br />2
<br />COATS WALL SATIN
<br />PLASTER
<br />AND DRYWALL,
<br />1
<br />COAT LATEX PRIMER SEAL
<br />2
<br />COATS LATEX ENAMEL
<br />MOISTURE
<br />RESISTANT GYPSUM BOARD,
<br />2
<br />COATS SELF -PRIMING SCRUBBABLE LATEX
<br />INTERIOR
<br />WOOD TRIM,
<br />1
<br />COAT ENAMEL UNDERCOAT
<br />2
<br />COATS SEMI -GLOSS ENAMEL
<br />CERAMIC TILE & STONE
<br />1. PROVIDE GLAZED CERAMIC FLOOR AND WALL TILE THAT COMPLIES WITH ANSI A1371
<br />2. PROVIDE STONE THRESHOLDS UNIFORM IN COLOR AND FINISH, 2' WIDE BY FULL WIDTH
<br />OF WALL OR FRAME OPENING, 1/2' THICK, AND COMPLYING WITH ASTM C 503,
<br />3. INSTALL TILE AND GROUT IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF ANSI
<br />4108.1 THROUGH A108,13,
<br />RESILIENT BASE
<br />1. RESILIENT BASE SHALL BE MANUFACTURER'S BEST GRADE, RUBBER OR VINYL BASE,
<br />WITH P:REMOLDED INTERNAL AND EXTERNAL CORNER PIECES. THE HEIGHT AND COLOR
<br />SHALL BE AS SHOWN ON THE PLANS,
<br />2. ADHESIVE SHALL BE AS RECOMMENDED BY BASE MANUFACTURER,
<br />3. BASES SHALL BE FIRMLY AND TOTALLY ATTACHED TO WALLS WITH ADHESIVE AND
<br />SHALL BE ACCURATELY SCRIBED TO TRIM, MOLDING AND CABINETS. ALL JOINTS
<br />SHALL BE TIGHT FITTING. FILLER PIECES SHALL BE NOT LESS THAN 18 INCHES,
<br />REFELCTED CEILING LEGEND
<br />SYM, I DESCRIPTION
<br />�g
<br />LIGHT FIXTURE - 2' TRACK
<br />0
<br />2'X4' LAY -IN FLUORESCENT
<br />LIGHT FIXTURE
<br />El
<br />2'X4' LAY -IN FLUORESCENT
<br />LIGHT FIXTURE
<br />El
<br />2'X4' SURFACE MTD. FLUORESCENT
<br />LIGHT FIXTURE
<br />1--i
<br />FLUORESCENT LIGHT FIXTURE - 3' STRIP
<br />C7
<br />FLUORESCENT LIGHT FIXTURE - 3' STRIP
<br />O
<br />LIGHT FIXTURE - RECESSED CAN 75W
<br />D
<br />LIGHT FIXTURE - WALL SCONCE
<br />LIGHT FIXTURE - PENDANT
<br />L�
<br />EMERGENCY BATTERY UNIT WITH TWO
<br />ADJ HEADS
<br />®
<br />EXIT LIGHT - BATTERY BACK-UP
<br />SUPPPLY DIFFUSER
<br />1 ® 1 SUPPPLY DIFFUSER
<br />RETURN GRILLE
<br />0 EXHAUST FAN
<br />Q SPRINKLER HEAD
<br />OM
<br />�
<br />°'
<br />y
<br />8
<br />c
<br />o
<br />¢
<br />N
<br />4
<br />�
<br />0
<br />C
<br />°'
<br />o 0.°
<br />0 rn
<br />w
<br />a
<br />0o
<br />CZ
<br />Lo
<br />En
<br />U
<br />J
<br />C
<br />Q
<br />y
<br />c
<br />C
<br />.J
<br />LL
<br />od
<br />0
<br />0
<br />0
<br />t7;?
<br />0
<br />N
<br />�'L
<br />a U")
<br />0
<br />N
<br />LLJ'
<br />x
<br />..a.l
<br />0 Ix tU)
<br />_.,
<br />U.
<br />Z
<br />�
<br />� J
<br />O
<br />Ll_
<br />W_.1WJ
<br />Ill
<br />J . j
<br /><�
<br />a
<br />d
<br />O
<br />NMN
<br />LJL
<br />Revisions:
<br />Uj
<br />:5
<br />U
<br />a`
<br />J
<br />Z
<br />4
<br />LL
<br />W
<br />G'
<br />!"
<br />U
<br />o
<br />:;
<br />Project Number
<br />10052
<br />Date
<br />06-01-10
<br />Sheet Number
<br />A-2