L THE BUILDING IS DESIGNED TO BE 100 PERCENT SPRINKLED <br />(INCLUDING MECHANICAL EQUIPMENT, TELEPHONE EQUIPMENT, <br />ELECTRICAL EQUIPMENT ROOMS, CLOSETS AND OTHER <br />CONCEALED SPACES. SPRINKLERS THROUGHOUT THE BUILDING <br />OR OTHER APPROVED FIRE EXTINGUISHING SYSTEM(S) MUST BE <br />INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS: <br />NFPA-13 (2002) STANDARD FOR INSTALLATION OF <br />SPRINKLER SYSTEM, NFPA-101A (2001) LIFE SAFETY CODE, <br />NFPA-241 STANDARD FOR SAFEGUARDMG BUILDING <br />CONSTRUCTION AND DEMOLITION OPERATIONS (2000), <br />FLORIDA BUILDING CODE 2004—BUILDING WITH ALL CURRENT <br />REVISIONS, OR OTHER LOCAL BUILDING OR FIRE CODES, UL <br />AND FM RECUIREMENTS SHALL TAKE PRECEDENCE FOR THE <br />FIRE PROTECTION SYSTEM NSTALLATION. <br />2. THESE DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING <br />RECORD DRAWINGS WHICH MAY NOT REFLECT ACTUAL <br />FIELD CONDITIONS. THE CONTRACTOR SHALL VERIFY <br />THESE DRAWINGS WITH EXISTING FIELD CONDITIONS AND <br />NOTIFY THE ARCHITECT 4 ENGINEER IMMEDIATELY OF <br />INCONSISTENCIES BETWEEN THE DRAWINGS AND ACTUAL <br />CONDITIONS BEFORE PROCEEDING WITH CONSTRUCTION. <br />3. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT / <br />ENGINEER IMMEDIATELY IF ANY OF THE WORK <br />INDICATED IN THE CONTRACT DOCUMENTS CANNOT BE <br />PERFORMED DUE TO EXISTING FIELD CONDITIONS. <br />4. THE SUCCESSFUL FIRE PROTECTION CONTRACTOR SHALL <br />PREPARE FABRICATION DRAWINGS, AND SHALL <br />PROVIDE ALL MATERIAL 4 AND EQUIPMENT DATA USED <br />FOR THE CONSTRUCTION FOR ARCHITECT/E -%INFER <br />APPROVAL. <br />5. THIS CONTRACTOR SHALL INCLUDE COST OF INSTALLATION <br />FOR ADDITIONAL 3 (THREE) SPRINKLER HEADS WITH <br />PIPING t HANGERS AS A RESULT OF EXISTING CONDITIONS <br />AND COORDINATION WITH MECHANICAL, PLUMBING AND <br />ELECTRICAL SYSTEMS. <br />1 OR 2 HOUR FIRE RATED <br />GYM M WALLBOARD ASSEMBL <br />3M FIRE BARRIER© <br />Cr MW+ C4UL.K <br />© WALLBOARD GYPSIM • <br />CONSULT CURRENT UNDERWRITERS LABORATORIES, INC. <br />'FIRE RESISTANCE DIRECTORY" FOR DETAILS. <br />UL SYSTEM WLIVIS <br />F RATINGS -I AND 2 HR (SEE KEY NOTES ITEM 15) <br />T RATING - 0 HR <br />L RATMG AT AMBIENT - LESS THAN 1 CR" I/SQ FT <br />L RATING AT 400 F - LESS THAN I CFM/SQ FT <br />1=1RE Ph'�OTECTION NOTES <br />6. PIPE t FITTING <br />A STEEL PIPE: ASTM A53, ANSI/ASTM A135, BLACK, <br />WEIGHT, SCHEDULE 40. <br />B. STEEL FITTINGS: (ABOVE GRADE), ANSI/ASME B 1625, <br />BUTTWELD ENDS. ASTM A234, WROUGHT CARBON STEEL <br />AND ALLOY STEEL. ANSI/ASME 8165, STEEL FLANGES <br />AND FITTINGS. ANSI/ASME B WPM, FORCsED STEEL. SOCKET <br />WELDED AND THREADED. <br />C. CAST IRON FITTINGS: (ABOVE GRADE)1-1/2" AND <br />SMALLER ANSI/ASME 816.4, SCREWED FITTINGS. <br />D. GROOVED PIPING PRODUCTS: 250 PSI CUT AND <br />ROLL GROOVED PIPING CONNECTIONS 2" AND LARGER <br />(UL t FM). <br />I. HANGERS AND SUPPORTS <br />A PIPING SHALL BE SUPPORTED FROM THE BUILDING <br />STRUCTURE N ACCORDANCE WITH NFPA PAMPHLET NO. <br />13. HANGERS SHALL ALLOW FOR EXPANSION AND <br />CONTRACTION OF PIPE LINES. HANGERS SHALL BE IN <br />ACCORDANCE WITH NFPA PAMPHLET NO. 13. <br />B. WHERE PIPING IS REQUIRED TO BE HUNG FROM <br />OTHER THAN POURED CONCRETE OR METAL <br />STRUCTURE, SUBMIT PROPOSED METHOD OF SUPPORT <br />TO THE ENGINEER FOR APPROVAL PRIOR TO <br />INSTALLATION. <br />C. DISTANCE OF HANGERS FROM HEADS INSTALLED AT <br />THE END OF BRANCH LINE SHALL BE A MAXIMUM OF 2' <br />(TWO FEET) <br />8. THIS CONTRACTOR SMALL PROVIDE ALL MATERIAL, <br />EQUIPMENT AND OPTIONS REQUIRED FOR COMPLETION <br />OF THE SPRINKLERS INSTALLATION, FINAL TESTING AND <br />APPROVALS. <br />S, FINAL APPROVAL OF THE ENTIRE SYSTEM IS REQUIRED <br />FROM THE AUTHORITY HAVING JURISDICTION. <br />2O. THROUGH PENETRAN ' T - ONE METALLIC PIPE OR CONDUIT TO <br />BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY <br />WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN <br />PIPES OR CONDUITS AND PERIPHERY OF OPENING SHALL BE MIN. <br />1/4 IN. TO MAX. 2 IN. PIPE OR CONDUIT TO BE RIGIDLY <br />SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY THE <br />FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR <br />CONDUITS MAY BE USED: <br />OA STEEL PIPE - NOM 10 IN. DIAM (OR SMALLER) SCHEDULE 10 <br />(OR HEAVIER) STEEL PIPE. <br />OB. IRON PIPE - NOM 10 IN. DIAM (OR SMALLER) CAST OR <br />DUCTILE IRON PIPE. <br />CO. CONDUIT - NOM 4 IN. DIAM (OR SMALLER) ELECTRICAL <br />METALLIC TUBING, NOM 6 IN. DIAM (OR SMALLER) STEEL <br />CONDUIT OR NOM 1 IN. DIAM (OR SMALLER) FLEXIBLE STEEL <br />TUBING. <br />D. COPPER PIPE - NOM 4 N. DIAM (OR SMALLER) REGULAR (OR <br />HEAVIER) COPPER PIPE. <br />OCOPPER TUBE - NOM 4 IN. DIAM (OR SMALLER) TYPE L (OR <br />HEAVIER) COPPER TUBE. <br />1�3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF <br />THE FOLLOWING: <br />AA TALLIC SLEEVE -CYLINDRICAL SLEEVE FABRICATED FROM <br />0.0165 IN. THICK (28 GAUGE) GALV SHEET STEEL AND HAVING <br />A MIN 2 IN. LAP ALONG THE LONGITUDINAL SEAM. LENGTH OF <br />STEEL SLEEVE TO BE 1 IN. GREATER THAN THE THICKNESS OF <br />NOTES WALL. SLEEVE INSTALLED BY COILING THE SHEET STEEL TO <br />KEYlO. WALL ASSEMBLY - THE I OR 2 MR FIRE -RATED GYPSUM <br />WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED <br />OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE <br />INDIVIDUAL U300 OR U400 SERI S WALL OR PARTITION DESIGN <br />IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE <br />THE FOLLOWING CONSTRUCTION FEATURES: <br />A.STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD <br />STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST <br />OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC WITH NOM 2 BY <br />4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS <br />TO BE MIN. 3-5/8 IN. WIDE AND SPACED MAX. 24 N. OC. <br />OB. WALLBOARD, GYPSUM' - 5/8 IN. THICK, 4 FT WIDE WITH <br />SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, <br />THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET <br />ORIENTATION SHALL BE AS SPECIFIED N THE INDIVIDUAL <br />U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE <br />DIRECTORY. MAX. DIAM OF OPENING IS 13 IN. THE HOURLY <br />F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE <br />HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT <br />IS INSTALLED. <br />A DIAM SMALLER THAN THE THROUGH OPENING, INSERTING <br />THE COIL THROUGH THE OPENINGS AND RELEASING THE COIL <br />TO LET IT UNCOIL AGAINST THE CIRCULAR CUTOUTS N THE <br />GYPSUM WALLBOARD LAYERS. THE ENDS OF THE STEEL <br />SLEEVE SHALL EXTEND MIN. 1/2 IN. BEYOND EACH SURFACE <br />OF THE WALL. <br />B.B. PACKING MATERIAL - IN 2 HR FIRE RATED ASSEMBLIES, MIN. <br />6-1/8 IN. THICKNESS OF 4 PCF MINERAL WOOL FIRMLY <br />PACKED INTO OPENING AS A PERMANENT FORM. IN 1 HR FIRE <br />RATED ASSEMBLIES MIN. 4-1/8 IN. THICKNESS OF 4 PCF <br />MINERAL WOOL FIRMLY PACKED INTO OPENING AS A <br />PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM <br />BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE <br />REQUIRED THICKNESS OF FILL MATERIAL. <br />CO. FILL, VOID OR CAVITY MATERIAL• - SEALANT - MIN. 1/2 IN. <br />THICKNESS OF FILL MATERIAL WITHIN ANNULUS, FLUSH WITH <br />ENDS OF STEEL SLEEVE. A MIN. 1/4 IN. BEAD OF FILL <br />MATERIAL SHALL BE APPLIED AT THE STEEL SLEEVE/GYPSUM <br />WALLBOARD INTERFACE ON BOTH SURFACES OF WALL. <br />SPECIFIED TECHNOLOGIES INC. - SRECSEAL 100, 101 OR <br />105 SEALANT <br />• BEARING THE UL CLASSIFICATION MARKING <br />0 1 t 2 NR RATED G5 WALL PIPE PENETRATION DETAIL <br />SCALE: N.T.S. LILSYSTEM LUL 1079 - METAL PIPE <br />10. IN AREA WHERE CEILING MOUNTED EQUIPMENT TO BE <br />INSTALLED ALL SPRINKLER HEADS SHALL BE <br />CONCEALED. <br />11. ALL NEW BRANCH PIPING SHALL BE IN <br />UNLESS OTHERWISE NOTED. <br />12. SPRINKLERS 155OF 'TEMPERATURE RATING SHALL BE AS <br />PER PLANS SPECIFICATION AS NOTED ON THE <br />DRAWINGS t NFPA-13 (2002). UNLESS OTHERWISE NOTED <br />ON PLAN. <br />13. INSTALL NEW PENDENT SPRINKLER HEADS IN <br />THE CENTERS OF CEILING TILES WHERE POSSIBLE. <br />14. PROVIDE SET OF SPARE SPRINKLER HEADS, WRENCH <br />IN CABINET. INSTALL WITH SPARE HEADS CABINET IN <br />FIRE CONTROL ROOM. <br />15. NEW HEADS LOCATIONS AND DISTANCE FROM <br />WALLS FOR SMALL t LARGE ROOMS SHALL COMPLY <br />WITH NFPA-13 (2002) STANDARDS. <br />16. COORDINATE DOWNTIME FOR EACH WORK PHASE WITH <br />THE OWNER <br />11. THE CONTRACTOR DOING THE SHEET METAL SHOP <br />DRAWINGS AND THE PLUMBING, FIRE PROTECTION, <br />HVAC FOREMAN, t GENERAL CONTRACTOR SHALL <br />INSPECT t REVIEW THE CONDITIONS AND SHALL <br />COORDINATE THEIR WORK SO AS TO PROVIDE <br />ADEQUATE SPACE ALLOWANCE ABOVE CEILING FOR <br />ALL TRADES. THE FIRE PROTECTION CONTRACTOR <br />SHALL INCLUDE IN HIS BID PACKAGE RELOCATION OF <br />BRANCH PIPING AS PER NOTE 5 FROM THE AREA <br />REQUIRED FOR DUCTWORK OR HVAC EQUIPMENT. <br />ROP- IN ANCHOR <br />• <br />D <br />ROD C0UPL <br />ATR <br />IVEL RING <br />OPCL� <br />00 <br />10 <br />10 <br />00 <br />00 <br />00 <br />00 <br />00 <br />I -BEAM <br />A.T.R <br />SWIVEL R <br />TOP OF TRUSSES <br />C-CLAMP <br />STEEL TRUSSE <br />JIL <br />AT.R <br />SWIVEL <br />HAW. -ER 4 10IPE SI, FrORTS <br />o <br />ASSE1" IDLY <br />DETAIL <br />SCALE: N.T.S. <br />SCREWED ELBOW <br />EXISTING SCREWED <br />ELBOW OR TEE —\ <br />LINE (TYPICAL) <br />CEILING <br />ICI PENANT W'ER 14EAD DETAIL <br />OCALE: N.Tb. <br />FIRE PROTECTION SI-IEET INDEX <br />FPl FIRE PROTECTION NOTES t DETAILS <br />FP2 FIRE PROTECTION FLOOR PLAN t DESIGN CRITERIA <br />101 FIRE PROTECTION DETAILS t NOTES <br />SCALE: N.T.S. hR�jN <br />REVISIONS <br />BY <br />0 <br />U <br />ui <br />U <br />U <br />�00> <br />0Y ce <br />oS_ <br />x E <br />.r <br />5 EIJ <br />N <br />0. M <br />o <br />O <br />CO <br />U O <br />¢ <br />E <br />Q�ti <br />3 ti <br />o� cc <br />ti� <br />C)LO <br />N ti <br />CO <br />00 <br />ti <br />✓ <br />ti <br />N <br />ti <br />a <br />_ <br />1 <br />s <br />a <br />C <br />0 <br />Ci Z m C3 <br />C <br />m <br />c <br />w <br />�8 <br />V' <br />CD <br />C <br />c <br />> <br />¢ m co <br />w uS <br />Lb <br />U_ <br />Z L <br />0 <br />J 0 <br />O <br />L C <br />J 04 <br />�•'' <br />V) 0 <br />._ N <br />_y W <br />m LLJ <br />L <br />L <br />0 <br />0 0 <br />L <br />r E <br />M <br />� m <br />0 <br />J <br />Li. <br />Date: 02. 09. 11 <br />Scale: AS NOTED <br />Project Mgr: <br />RT <br />Drawn: <br />VK <br />Job: 10-65 <br />Sheet <br />FP1 <br />