Template:
Building Plans
Street #
38051
Location
Market Square
Contractor
Wallace Associates LLC
Building Plans - Permit #
11806
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CABINET IN NON RATED WALL <br />MODEL NO. 1021F12 AS MANUFACTURED <br />BY J.L. INDUSTRIES. <br />CABINET IN RATED WALL <br />MODEL NO. 1021FI2 FX AS MANUFACTURED <br />BY J.L. INDUSTRIES AT 6" WALLS <br />MODEL NO. 1022FI2 FX AS MANUFACTURED <br />BY J.L. INDUSTRIES AT 4" WALLS <br />GYPSUM <br />WALLBOARD <br />PER WALL TYPE <br />FIRE <br />EXTINGUISHER <br />SEE SPECS. <br />BOTTOM OF CABINET <br />TOP OF WALL <br />4" METAL STUDS <br />AT 16" O.C. <br />FLOOR SLAB <br />101 FIRE EXTWsU1%*2Lr=T&=R <br />SCALE: 1 1/2" = I'-0" <br />20 GA. STEEL CHANNEL <br />FASTEN TO STRUCTURE <br />ABOVE <br />3 5/8" 25 GA. <br />GALV. STEEL <br />STUDS AT 6'-0" <br />ofTYPICAL PA►WITION <br />SCALE: 1 1/2" 2 I'-0" <br />LAY -IN ACOUSTICAL <br />OR GYPSUM BOARD <br />CE IL INC. <br />1/2" x 48" WIDE G.W.B. APPLIED <br />HORIZONTALLY OR VERTICALLY, <br />CORNER JOINTS OVER STUDS, <br />STAGGER I6" O.G. OPPOSITE SIDES. <br />ATTACH TO STUDS AND RUNNERS <br />WITH I" LONG TYPE "S" SCREWS AT <br />THE JOINTS 4 RUNNER CHANNELS <br />1/2" TO 3/4" FROM EDGES OF G.W.B. <br />SCREWS SHALL BE SPACED 8" O.G. <br />ALONG EDGES OF BOARD AND 12" <br />O.G. IN THE FIELD, COVER JOINTS <br />WITH TAPE AND JOINT COMPOUND <br />PER GA - WP - 1200. INCREASE <br />METAL STUD THICKNESS AS <br />REQUIRED FOR PLUMBING AND <br />ELECTRICAL. <br />3 5/8" OR 6" (SEE FLOOR PLAN) <br />GALV. STEEL STUDS AT 16" O.C, 20 <br />GA.STUDS AT WALL MOUNTED <br />EQUIPMENT <br />R-11 BLANKET INSULATION AT <br />SOUND PROOF PARTITIONS ONLY. <br />25 GA. GALV. STEEL CHANNEL <br />FASTEN TO SLAB AT 24" O.C. <br />FLOOR SLAB <br />DOOR o40 14ARDWARE SCNE_DULE <br />V-0" X 1'-0" X 1 3/4" S.C. WOOD DOOR IN H.M. FRAME WITH <br />PASSAGE HARDWARE SET AND AUTO CLOSER SEE DETAIL <br />5/Alb. <br />V-0" X 1'-0" X 1 3/4" S.C. WOOD DOOR IN H.M. FRAME WITH <br />STOREROOM HARDWARE SET. SEE DETAIL B/Alb. <br />© V-0" X 1'-0" X 1 3/4" S.C. WOOD DOOR IN H.M. FRAME WITH <br />PRIVACY HARDWARE SET. SEE DETAIL B/Alb. <br />V-0" X 1'-0" X 1 3/4" S.C. WOOD DOOR IN H.M. FRAME WITH <br />OFFICE HARDWARE SET. SEE DETAIL B/Alb. <br />0 V-0" X 1'-0" X 1 3/4" S.C. WOOD DOOR IN H.M. FRAME WITH <br />OFFIC ENTRANCE DOOR SET AND AUTOCLOSER. SEE DETAIL <br />5/Alb. <br />0 EXISTING DOOR SYSTEM TO REMAIN. VERIFY WORKING <br />CONDITION. REPLACE HARDWARE AS REQUIRED <br />HINGES <br />: CAL -ROYAL <br />- U6260 <br />- 5B31xUS26,TBH31xUS26 <br />CLOSER <br />LCN <br />- US260 <br />- 1460/1441 <br />WALL STOP <br />: CAL -ROYAL <br />- U926D <br />- CONW542 <br />FLOOR STOP <br />: CAL -ROYAL <br />- U8260 <br />- DSHPIS <br />PASSAGE SET <br />: SCHLAGE <br />- U8260 <br />- SATURN AL10S <br />PRIVACY SET <br />SCHLAGE <br />- U9260 <br />- SATURN AL40S <br />LOCK SET <br />: SCHLAGE <br />- U9260 <br />- SATURN AL50PO <br />SINGLE DUMMY TRIM <br />: SCHLAGE <br />- U5260 <br />- SATURN AL110 <br />STOREROOM LOCK <br />: SCHLAGE <br />- U9260 <br />- SATURN AL80PO <br />CLASSROOM LOCK <br />: SCHLAGE <br />- U9260 <br />- SATURN AL10P0 <br />THRESHOLD <br />: PEMKO <br />- ALUM <br />- 210A or 110A <br />DOOR SWEEP <br />: PEMKO <br />- ALUM <br />- 315CN <br />PULL HANDLE <br />: DON-JO <br />- US26D <br />- 1114 <br />KICK PLATE <br />: DON-JO <br />- ALUM <br />- J102 <br />PANIC DEVICE <br />: MONARCH <br />- MAL <br />- ISIOLDANE <br />KEYED NOTES CONT. <br />32 EXISTING STAIR - NO WORK THIS AREA. <br />33 LIGHTING MANAGER PANEL - SEE ELECTRICAL. <br />34 EYE WASH SYSTEM - SEE PLUMBING. <br />35 3 5/8" METAL STUDS FRAMED PLUMBING WALL. <br />36 THIS DOOR SHALL BE A WOOD/GLASS PANEL DOOR <br />31 PROVIDE NEW DOOR SKIN/VENEER ON OFFICE SIDE OF EXISTING <br />DOOR FINISH TO MATCH ALL NEW DOORS. <br />38 GARBAGE DISPOSAL THIS SINK - SEE PLUMBING. <br />DOOR CSENEI"L NOTES <br />I. ALL DOORS/DOOR OPENINGS SHALL COMPLY WITH FLORIDA FIRE <br />PREVENTION CODE 2001 EDITION / NFPA 101 LIFE SAFETY CODE <br />12.1.2 WIDTH <br />12.1.4 SWING AND FORCE TO OPEN <br />12.1B LOCKS AND LATCHES AND ALARM DEVICES <br />12.116 SPECIAL LOCKING ARRANGEMENTS <br />12.1.1 PANIC HARDWARE AND FIRE EXIT DEVICES <br />12.1.8 SELF CLOSING DEVICES <br />2. ALL DOOR HANDLES SHALL BE LEVER TYPE MEETING A.D.A. <br />REQUIREMENTS. <br />3. ALL INTERIOR DOOR HANDLES SHALL BE SCHLAGE "AL" SERIES <br />"SATURN" <br />4. ALL DOORS WITH AUTO CLOSERS SHALL HAVE BALL BEARING TYPE <br />HINGES <br />5. ALL NEW INTERIOR DOORS SHALL BE BIRCH VENEER <br />6. DOOR CLOSER SHALL BE INSTALLED SUCH THAT THE SWEEP PERIOD <br />OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN <br />POSITION OF 10% THE DOOR WILL TAKE AT LEAST 3 SECONDS TO <br />MOVE TO A POINT 3 INCHES (16MM) FROM THE LATCH, MEASURED TO <br />THE LEADING EDGE OF THE DOOR <br />1. THE MAXIMUM FORCE FOR PUSHING OR PULLING AN INTERIOR DOOR <br />SHALL BE 51bf (222N). <br />S. PROVIDE EITHER WALL OR FLOOR STOPS FOR ALL DOORS AS <br />REQUIRED. <br />S. SUBMIT HARDWARE SCHEDULE AND REVIEW WITH ARCHITECT PRIOR <br />TO PLACING ORDER (3 COPIES) <br />O FLOOR PLAN <br />SCALE: 3/16" = I'-0" <br />KEYED NOTES <br />OEXISTING STRUCTURAL COLUMN - MAINTAIN INTEGRITY DURING <br />CONSTRUCTION <br />O2 EXISTING EXTERIOR WALL SYSTEM <br />OEXISTING ELEVATOR <br />O4 PATCH AND REPAIR EXISTING WALL TO MATCH AND ALIGN WITH <br />ADJACENT EXISTING WALL <br />OWATER HEATER - SEE PLUMBING <br />OBASE CABINETS / COUNTERTOP - SEE INTERIOR ELEVATIONS <br />OWALL MOUNTED UPPER CABINETS - SEE INTERIOR ELEVATIONS <br />O42" HIGH COUNTER - SEE INTERIOR ELEVATIONS <br />OSTAINLESS STEEL SINK - SEE PLUMBING <br />ID U.C. REFRIGERATOR - SELECTED BY OWNER - VERIFY HEIGHT <br />II ALIGN NEW WALL WITH EXISTING WALL <br />12 LINE OF KNEE WALL BELOW <br />13 BUILT-IN SHELVING - SEE DETAIL II/A4a. <br />14 FIRE EXTINGUISHER - SEE DETAIL B/Ala. <br />15 36" HIGH WRITING SURFACE - SEE INTERIOR ELEVATIONS <br />16 NEW ELECTRICAL PANEL - SEE ELECTRICAL DRAWINGS <br />11 NEW PHONE50ARD - SEE ELECTRICAL DRAWINGS <br />18 REFRIGERATOR BY TENANT <br />19 CUBICAL CURTAIN SYSTEM BY EMPERIAL FASTENER COMPANY OR <br />EQUAL, IFC-98 TRACK WITH IFC-100 CARRIERS. <br />20 4'-0" W. x V-8" H. INTERIOR WINDOWS SYSTEM IN HOLLOW METAL <br />FRAME - SEE DETAIL D/Alb - WINDOW HEAD TO MATCH DOOR <br />HEADS. <br />21 SLIDING SATIN ANODIZED ALUMINUM CRL WINDOW X-OR-X FORMAT <br />WITH 1/4" TEMPERED CLEAR GLASS AND FIXED GLASS PANELS <br />22 FLAT PANEL TV - PROVIDED BY OWNER - INSTALLED BY G.C. - <br />PROVIDE BLOCKING AS REQUIRED. <br />23 HI-LO DRINKING FOUNTAIN - SEE PLUMBING DRAWINGS <br />24 30" WRITING SURFACE - SEE INTERIOR ELEVATION <br />25 UNDER COUNTER DISHWASHER BY TENANT <br />26 36" GRAB BARS. COORDINATE EXACT LOCATION WITH TENANT. <br />0 <br />21 BOX OUT EXISTING COLUMN WITH 1/2" G.W.B. OVER METAL STUD <br />FRAMING AS REQUIRED. KEEP SIZE TO MINIMUM. <br />28 FREEZER UNIT BY TENANT. <br />29 WOOD CASED OPENING - SEE DETAIL C/Alb. <br />30 EQUIPMENT BY TENANT. <br />31 EXISTING FIRE RATED WALL, MAINTAIN INTEGRITY DURING <br />CONSTRUCTION. <br />UJ�I L LEGEND <br />—� EXISTING DOOR SYSTEM <br />—. — EXISTING WALL PARTITION <br />—_ — EXISTING ONE HOUR RATED WALL PARTITION TO REMAIN <br />EXISTING EXTERIOR WALL SYSTEM <br />4" <br />DOOR SYSTEM - REFER TO DOOR SCHEDULE <br />METAL STUD PARTITION - REFER TO TYPICAL NON-RA1 <br />WALL PARTITION DETAIL A/Ala <br />METAL STUD SOUND INSULATED PARTITION - REFER TO <br />TYPICAL NON -RATED WALL PARTITION DETAIL A/Ala <br />GENERAL NOTES <br />I. GENERAL CONTRACTOR TO NOTIFY ARCHITECT AFTER LAYOUT IS <br />DONE AND WALL TRACK IS IN PLACE PRIOR TO FRAMING ANY WALLS. <br />2. ALL BIDDERS ARE REQUIRED TO VERIFY EXISTING CONDITIONS PRIOR <br />TO ANY BIDDING. NOTIFY ARCHITECT FOR ANY DISCREPANCY. <br />3, ALL NEW GWB TO RECEIVE SMOOTH LEVEL (4) FINISH. <br />4. PREP FLOOR SLAB FOR INSTALLATION OF NEW FLOOR FINISHES AS <br />REQUIRED. PROVIDE COMPLETE OVERLAY IF REQUIRED. <br />5. CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING CONDITIONS. <br />ANY PROPOSED DESIGN AS SHOWN ON THESE PLANS WHICH ARE IN <br />CONFLICT WITH EXISTING CONDITIONS MUST BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT / ENGINEER OF RECORD PRIOR TO ANY <br />DEMOLITION OR CONSTRUCTION COMMENCES. <br />6, SEE IDI SHEET FOR FINISH SCHEDULES. <br />1, GENERAL CONTRACTOR TO NOTIFY ARCHITECT OF ANY <br />DISCREPANCIES PRIOR TO COMMENCING WITH ANY WORK. <br />g, GENERAL CONTRACTOR TO MAINTAIN INTEGRITY OF ALL EXISTING <br />STRUCTURAL ELEMENTS AND FIRE RATED WALLS DURING <br />CONSTRUCTION AS REQUIRED. <br />S. PATCH AND REPAIR EXISTING GWB TO LOOK LIKE NEW. VENEER OVER <br />EXISTING IF REQUIRED. <br />10. SEE DOOR CLEARANCES DETAIL A/Ald <br />11. GENERAL CONTRACTOR TO COORDINATE WITH BUILDING MANAGER <br />FOR ALL NEW PLUMBING AND ELECTRICAL WORK REQUIRED BELOW <br />THE FLOOR SLAB ABOVE CEILING IN THE SUITE BELOW. <br />REVISIONS <br />BY <br />� <br />o <br />`-_" <br />oo - <br />Z o <br />M <br />U b0 <br />'- <br />�. <br />0 <br />v A U <br />E <br />= <br />- E 1i] U <br />r�r • <br />00 U . <br />�I <br />¢Q�ti o <br />Y > ti 3 <br />3 <br />._� <br />o z X <br />'_■ <br />I <br />E ~o <br />r N <br />C <br />✓ <br />ti <br />r- <br />ti <br />a <br />.F <br />Q <br />Q00 <br />N <br />^ ) <br />'C7 � <br />O O <br />^ ly CC <br />Q <br />?O o <br />U U <br />(n 61 <br />U <br />a� <br />0 <br />0 <br />I <br />U_ <br />Z <br />L <br />0 <br />J <br />0 <br />v <br />z <br />3 J <br />CV .L <br />N 0 <br />1 V <br />} LL_ <br />N i <br />mLLJ <br />0 ;.L <br />0 <br />_ <br />t <br />Lo <br />N <br />= Q <br />E 0 <br />D M <br />0 <br />L <br />QC <br />J <br />Date: 02. 09. 11 <br />Scale: AS NOTED <br />Project <br />Mgr: AAY <br />Drawn: DC <br />Job: 10-65 <br />Sheet <br />Ala <br />H:\Projects\Projects 2010\1065 - FMC ZH Rheuinatology Suite\CD\CD.A\Architectunl\A]a-FLPL.dwg, 2/14/2011 3:04:41 PM, DC <br />