Iva --z7" UZI z I a <br />GENERAL NOTES <br />1. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITION OF THE NATIONAL FIRE <br />CODE "FLORIDA BUILDING CODE," "FLORIDA PLUMBING CODE," "FLORIDA MECHANICAL <br />CODE," "NATIONAL ELECTRICAL CODE," AND ALL OTHER APPLICABLE LOCAL, STATE, AND <br />FEDERAL CODES AND ORDINANCES, AND ALL AUTHORITIES HAVING LOCAL JURISDICTION. <br />2. THE GENERAL CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH THE <br />CURRENT EDITION OF THE "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" <br />AIA DOCUMENT A201. <br />3. THE CONTRACTOR SHALL, UPON DISCOVERY, GIVE WRITTEN NOTICE TO THE ARCHITECT OF <br />ANY MATERIALS, EQUIPMENT, OR DESIGN FEATURES WHICH HE BELIEVES TO BE <br />INADEQUATE OR UNSUITABLE, IN VIOLATION OF LAWS, ORDINANCES, OR RULES AND <br />REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION OVER THE WORK, AND OF ANY <br />NECESSARY ITEMS OR WORK OMITTED FROM THE DRAWINGS, <br />4. ALL SUBCONTRACTORS SHALL USE ONLY SKILLED CRAFT <br />SMEN, EXPERIENCED <br />P ED IN THE , <br />WORK OF THEIR TRADE, TO ENSURE FIRST CLASS WORKMANSHIP. ANY WORK NOT EQUAL <br />TO BEST TRADE STANDARDS SHALL BE REMOVED AND REPLACED AT NO ADDITIONAL <br />COST. SHOULD ANY SUBCONTRACTOR REFUSE TO REMOVE AN <br />D REPLACE <br />UNSATISFACTORY WORK, THE CONTRACTOR MAY REMOVE AND REPLACE IT, AND CHARGE <br />THE COST TO THE SUBCONTRACTOR. <br />5. IT 15 THE GENERAL CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION <br />PROCEDURE AND SEQUENCE TO ENSURE THE SAFETY OF PEOPLE AND OF THE BUILDING <br />AND ITS COMPONENT PARTS DURING CONSTRUCTION. THIS INCLUDES, BUT 15 NOT LIMITED <br />TO, THE ADDITION OF WHATEVER TEMPORARY BRACING OR TIE DOWNS THAT MAY BE <br />NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY <br />OF THE CONTRACTOR AFTER COMPLETION OF THE PROJECT. <br />6. ALL PRODUCTS AND PARTS SHALL FIT TOGETHER NEATLY, WITHOUT DAMAGE OR <br />DISFIGUREMENT. EXCEPT FOR SPECIFIED CURVED SURFACES, ALL PRODUCTS AND PARTS <br />SHALL BE CONSTRUCTED/ FABRICATED AND INSTALLED TRUE, IN LINE, AND PLUMB. ALL <br />NON CONFORMING WORK SHALL BE REJECTED AND RE -ACCOMPLISHED BY THE GENERAL <br />CONTRACTOR AT NO ADDITIONAL COSTS TO THE OWNER <br />1. ALL WORK SHOWN ON THE DRAWINGS SHALL BE CONSTRUCTED OF NEW COMPONENTS. <br />8. ALL BIDS SHALL BE PREPARED FROM A COMPLETE SET OF CONSTRUCTION DOCUMENTS. <br />COMPLETE SETS OF DOCUMENTS SHALL NOT BE BROKEN UP FOR BID PURPOSES. SUCH <br />ACTION MAY RESULT IN A LACK OF INFORMATION IN REFERENCE TO THE SCOPE OF WORK <br />TO BE PERFORMED. <br />e. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO PERSONALLY FIELD <br />INSPECT THE PROJECT SITE PRIOR TO THE PREPARATION AND SUBMITTAL OF HIS BID. <br />THIS INSPECTION IS REQUIRED SO THAT THE CONTRACTOR SHALL BE TOTALLY FAMILIAR <br />WITH THE EXISTING CONDITIONS AND THEIR INTERFACE WITH THE NEW CONSTRUCTION AS <br />DEFINED IN THESE CONSTRUCTION DOCUMENTS. <br />10, UNLESS OTHERWISE SPECIFIED, THE G.C. SHALL FURNISH A WRITTEN GUARANTEE FOR ALL <br />WORK (EQUIPMENT, MATERIALS, AND LABOR), AGAINST ANY DEFECTS IN SAID WORK FOR A <br />PERIOD OF ONE 0) YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION, WITH ALL <br />APPROPRIATE REPAIRS OR REPLACEMENTS AT NO ADDITIONAL COST TO THE OWNER. <br />11. IT SHALL BE THE RESPONSIBILITY OF THE G.C. AND/OR CONTRACTORS TO COMPLY WITH <br />ALL THE REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND HEALTH ACT OF n10 BY <br />THE U.S. DEPARTMENT OF LABOR, AND REQUIRE ALL ITS SUBCONTRACTORS AND <br />EMPLOYEES TO COMPLY WITH THIS LAW, AND ANY RELATED STATE OR LOCAL LAWS. <br />12. THE DATA GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED. <br />THEIR ABSOLUTE ACCURACY IS NOT GUARANTEED, AND THE G.C. SHALL OBTAIN EXACT <br />LOCATIONS, MEASUREMENTS, LEVELS, ETC. AT THE SITE AND SHALL SATISFACTORILY <br />ADAPT HIS WORK TO THE ACTUAL CONDITIONS OF THE BUILDING. DO NOT SCALE PRINTS. <br />VERIFY ALL DIMENSIONS WITH THE ARCHITECT PRIOR TO COMMENCING WORK <br />13. THESE DOCUMENTS AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE ALTERED IN <br />ANYWAY BY THE CONTRACTOR OR THE OWNER ALTERATIONS SHALL BE MADE ONLY BY <br />THE ARCHITECT OF RECORD. <br />14. THE EXISTING FACILITY IS ACCOMMODATED WITH A FIRE SPRINKLER SYSTEM. ANY AND ALL <br />INSTALLATIONS, CHANGES, ADDITIONS, RELOCATIONS, IMPROVEMENTS AND/OR <br />MODIFICATIONS TO THE FIRE SPRINKLER SYSTEM NECESSITATED BY THE WORK IN THIS <br />PERMIT SHALL BE DONE AS PER NFPA-13 2001 EDITION, BY A LICENSED FIRE SPRINKLER <br />CONTRACTOR WITH SEPARATE PERMIT AND PLANS. <br />15. THE EXISTING FACILITY IS ACCOMMODATED WITH A FIRE ALARM SYSTEM. ANY AND ALL <br />INSTALLATIONS, CHANGES, ADDITIONS, RELOCATIONS, IMPROVEMENTS AND/OR <br />MODIFICATIONS TO THE FIRE ALARM SYSTEM SHALL BE DONE AS PER NFPA-12 2001 <br />EDITION, BY A LICENSED FIRE ALARM CONTRACTOR WITH SEPARATE PERMIT AND PLANS. <br />16. ALL FIRE PROTECTION SYSTEMS SHALL REMAIN IN SERVICE DURING CONSTRUCTION AT ALL <br />TIMES. <br />38135 MARKT SQUARE <br />-1[11 a 01 4 <br />Kea <br />rV <br />Oki <br />M%imml <br />CONSTRUCTION NOTES <br />1. INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILING SHALL BE IN ACCORDANCE <br />WITH ASTM E84. ALL FINISH MATERIALS SHALL MEET A CLA55 "B" INTERIOR FINISH RATING <br />IN EXIT AND EXIT ACCESS AREA. CLASS "C" ELSEWHERE. <br />2. ALL EXIT DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A <br />KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT. MANUALLY OPERATED FLUSH BOLTS OR <br />SURFACE BOLTS SHALL NOT BE USED. <br />3, ALL GLAZING WITHIN A 24 INCH ARC OF DOORS WHOSE BOTTOM EDGE 15 LESS THAN 60 <br />INCHES ABOVE THE FLOOR AND GLASS BELOW 18'' A.F.F. AND ALL GLAZING IN DOORS <br />SHALL BE SAFETY GLASS, TEMPERED GLASS OR ACRYLIC PLASTIC SHEET. PER <br />FBC-2406.1 <br />4. OBJECTS PROTRUDING FROM WALLS WITH THEIR LEADING EDGES BETWEEN 21" AND 80" <br />ABOVE THE FINISHED FLOOR SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, <br />CORRIDORS, PASSAGEWAYS, OR AISLES. OBJECTS MOUNTED AT OR BELOW 21" ABOVE <br />FINISHED FLOOR MAY NOT PROTRUDE ANY AMOUNT. FREE STANDING OBJECTS MOUNTED <br />ON POST OR PYLONS MAY OVERHANG 12". PROTRUDING OBJECTS SHALL NOT REDUCE THE <br />CLEAR WIDTH OF AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. <br />5. PROVIDE DEADWOOD BLOCKING WITHIN WALL CAVITIES AT LOCATIONS INCLUDING, BUT NOT <br />LIMITED TO, WALL MOUNTED CABINETRY, FIRE EXTINGUISHER CABINETS, TOILET <br />ACCESSORIES, GRAB BARS, WALL STOPS, ETC- 186A. GALV. FLAT METAL MAY BE USED IN <br />LOCATIONS APPROVED BY ARCHITECT. <br />6. PROVIDE AND INSTALL PORTABLE FIRE EXTINGUISHERS A5 SHOWN IN THESE DOCUMENTS <br />OR AS OTHERWISE DIRECTED BY THE LOCAL FIRE MARSHAL. <br />1. SIGNAGE SHALL BE PROVIDED AS REQUIRED AND AS STATED IN THE 2012 FLORIDA <br />ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION AND SHALL COMPLY WITH CHAPTER 1 <br />SECTION 103 SIGNS, <br />SYMBOL LEGEND <br />x <br />xx <br />BUILDING SECTION <br />SYMBOL <br />x <br />xx WALL SECTION <br />SYMBOL <br />x <br />xx DETAIL <br />SYMBOL <br />00 <br />'� xx DETAIL <br />SYMBOL <br />0'-0" ELEVATION MARK <br />TOP OF SLAB <br />INTERIOR ELEVATION <br />x/A MARK <br />KEYED DRAWING NOTES <br />000 DOOR NUMBER <br />SYMBOL <br />ROOM NUMBER SYMBOL <br />WINDOW <br />SYMBOL <br />REVISION <br />/X,WALL TYPES <br />WILDING CODE INFORMATION <br />APPLICABLE CODES: <br />THE FLORIDA BUILDING CODE, 2010 EDITION <br />• BUILDING 0 EXISTING BUILDING <br />• PLUMBING 0 ELECTRICAL <br />• MECHANICAL <br />• 2012 FLORIDA ACCESSIBILITY CODE FOR <br />BUILDING CONSTRUCTION <br />FLORIDA FIRE PREVENTION CODE 2010 EDITION <br />NFPA 101 LIFE SAFETY CODE FLORIDA EDITION <br />NATIONAL ELECTRICAL CODE 2006 EDITION <br />2010 ADA STANDARDS FOR ACCESSIBLE DESIGN <br />OCCUPANCY CLASSIFICATION: EXISTING <br />FBC - BUILDING, CHAPTER 3 <br />SECTION 304: BUSINESS OCCUPANCY - GROUP B SPRINKLERED <br />CLASSIFICATION OF U1OIWs EXISTING FACILITY <br />FEBC - EXISTING BUILDING, SECTION 404 <br />ALTERATION LEVEL 2 <br />HEIGHT AND BUILDING AREA: (EXISTING) <br />FBC - BUILDING, CHAPTER 5: TYPE II-B, SPRINKLERED <br />AREA MODIFICATION FOR FRONTAGE INCREASE - 506.2 <br />0.0090 <br />AREA MODIFICATION FOR AUTOMATIC SPRINKLER SYSTEM - <br />506.3 0.00% <br />ALLOWED <br />PROVIDED <br />TABLE 503: HEIGHT AND BUILDING AREA <br />MAXIMUM BUILDING HEIGHT 55, <br />30, <br />MAXIMUM STORIES 3 <br />2 <br />AREA PER FLOOR 46,000 SF <br />26,038 SF <br />CONSTRUCTION TYPE: (EXISTING) <br />FBC - BUILDING, CHAPTER 6 <br />TABLE 601 - FIRE RESISTANCE RATING FOR BUILDING ELEMENTS <br />REQ'D <br />PROVIDED <br />STRUCTURAL FRAME INCLUDING <br />BEAMS, COLUMNS, GIRDERS, TRUSSES 0 HR <br />0 HR <br />BEARING WALLS, EXTERIOR 0 HR <br />0 HR <br />BEARING WALLS, INTERIOR 0 HR <br />0 HR <br />NONBEARING WALLS, INTERIOR 0 HR <br />0 HR <br />FLOOR CONSTRUCTION INCLUDING <br />SUPPORTING BEAMS t JOISTS 0 HR <br />0 HR <br />ROOF CONSTRUCTION INCLUDING <br />SUPPORTING BEAMS t JOISTS 0 HR <br />0 HR <br />TABLE 602 - FIRE RESISTANCE RATING FOR EXTERIOR WALLS BEARING <br />AND NON BEARING BASED ON FIRE SEPARATION <br />DISTANCE <br />LESS THAN 5' 1 HR <br />N/A <br />5' TO 10' 1 HR <br />N/A <br />10 TO 20 0 HR <br />N/A <br />20' TO 30' 0 HR <br />N/A <br />30' AND OVER 0 HR <br />0 HR <br />FIRE RESISTANCE s EXISTING FACILITY <br />N/A <br />MEANS OF EGRESS: <br />FBC - BUILDING, CHAPTER 10 <br />MAXIMUM FLOOR AREA PER OCCUPANT <br />TABLE 1004.1.1: 100 5F <br />GROUND FLR 2rc,036 SF 260 <br />PERSONS <br />EGRESS WIDTH PER OCCUPANT - TABLE 1005.1 <br />2 <br />260 x 0.2 <br />52.0" <br />ALLOW <br />PROVIDED <br />KEY PLAN <br />MIN. CLEAR DOOR OPENING - 1006.1.1 <br />32" <br />2 34" <br />SECTION SYMBOL <br />MIN. CLEAR STAIR WIDTH - 1009.1 <br />441' <br />2 48" <br />COMMON PATH OF TRAVEL - 1014.3 <br />100 FT <br />100 FT <br />EXIT ACCESS TRAVEL DIST. - TABLE 1016.1 <br />300 FT <br />< 300 FT <br />MIN. CORRIDOR WIDTH - 10162 <br />44" <br />2 44" <br />DEAD END CORRIDOR - 1018.4 <br />50 FT <br />< 50 FT <br />MIN. NUMBER OF EXITS - 1021.1 / 1021,2 <br />2 <br />4 <br />NUMBER AND SIZE OF EXITS <br />PROVIDED <br />DOUBLE ENTRANCE DOORS <br />34 X 2 = 68" <br />SINGLE ENTRANCE/EXIT DOOR <br />6ro X 2 = 132" <br />WILDING CODE INFORMATION CONT. <br />INTERIOR FINISHES: <br />FBC - BUILDING, CHAPTER 6 BUSINESS - GROUP B (SPRINKLERED) <br />INTERIOR WALL AND CEILING FINISH REQUIREMENTS - TABLE 803.9 <br />VERTICAL EXITS AND EXIT PASSAGEWAYS: CLASS A <br />EXIT ACCESS CORRIDORS / EXITWAYS: CLASS B <br />ROOMS AND ENCLOSED SPACES: CLASS C <br />INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN ACCORDANCE <br />WITH ASTM E 54. <br />SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE INSTALLED IN <br />ACCORDANCE WITH THE PROVISIONS OF 45TM C 635 AND ASTM C 636. <br />MATERIAL, OTHER THAN FOAM PLASTIC USED AS INTERIOR TRIM SHALL HAVE A <br />MINIMUM CLASS C FLAME SPREAD AND SMOKE -DEVELOPED INDEX WHEN <br />TESTED IN ACCORDANCE WITH ASTM E 84. <br />INTERIOR WALL SURFACES WITHIN (2) TWO FEET OF URINALS AND WATER CLOSETS <br />SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT OF (4) <br />FOUR FEET ABOVE THE FINISHED FLOOR MINIMUM. THE MATERIALS USED IN SUCH <br />WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. <br />PROJECT SCOPE <br />PARTIAL INTERIOR RENOVATIONS OF AN EXISTING MEDICAL OFFICE <br />WITHIN AN EXISTING MEDICAL OFFICE FACILITY. <br />FIRE PROTECTION SYSTEM TO BE DESIGNED AND SUBMITTED <br />UNDER A SEPARATE PERMIT BY A LICENSED FIRE PROTECTION <br />CONTRACTOR PRIOR TO PERMIT ISSUANCE. <br />PROJECT TEAM <br />ARC 41TECT <br />OLIVERI ARCHITECTS <br />32101 U.S. HWY.113 <br />PALM HARBOR, FLORIDA 34ro84 <br />121-181-1525 <br />PLUMBING <br />MDCI FLORIDA INC. <br />405 2ND STREET SOUTH, SUITE B <br />SAFETY HARBOR, FLORIDA 34695 <br />121-698-03S8 <br />MDCI FLORIDA INC. <br />405 2ND STREET SOUTH, SUITE B <br />SAFETY HARBOR, FLORIDA 34695 <br />121-698-0398 <br />ELECTRICAL <br />ELECTRICAL CONSULTING AND <br />DESIGN, INC. <br />g225 ULMERTON ROAD - SUITE G <br />LARGO, FLORIDA 33111 <br />121-581-4318 <br />AERIAL MAP <br />l C <br />d � 'iV, k U <br />l� <br />INDEX OF: DRAWINGS <br />Tl TITLE SHEET <br />Dl EXISTING / DEMOLITION FLOOR PLAN <br />DZ EXISTING / DEMOLITION REFLECTED CEILING <br />PLAN <br />Ala FLOOR PLAN <br />Alb DIMENSIONED FLOOR PLAN <br />A2 REFLECTED CEILING PLAN AND DETAILS <br />A3a INTERIOR ELEVATIONS <br />A3b INTERIOR ELEVATIONS <br />A3e INTERIOR ELEVATIONS <br />A4 CABINET DETAILS <br />IDl FINISH FLOOR PLAN AND SCHEDULE <br />N1 ARCHITECTURAL SPECIFICATIONS <br />PI PLUMBING RENOVATION PLAN <br />MI EXISTING / DEMOLITION MECHANICAL FLOOR PLAN <br />M2 MECHANICAL FLOOR PLAN <br />El ELECTRICAL LEGEND AND SPECIFICATIONS <br />E2 ELECTRICAL LIGHTING PLAN <br />E3 ELECTRICAL POWER PLAN <br />LOCATION MAP <br />�E <br />F,Wda <br />- w, . <br />'k <br />ibd3.j k, i L _ <br />Cottomwond Pi <br />a .. <br />PROJECT ' <br />51TE <br />REVISIONS <br />BY <br />.0C <br />O N <br />M �r <br />L LL <br />O <br />L C <br />U <br />E X N <br />O U • N .� <br />L � U <br />O � <br />Eti O <br />O r- <br />Ll <br />c � <br />G N1 <br />C"J <br />C E-? <br />C7 L0 <br />C5 <br />(r <br />d <br />Q <br />N <br />fr <br />ik <br />y <br />cf� <br />U <br />S <br />_ <br />L <br />0 U <br />N <br />LiJ <br />v U <br />O Q 0 m N "v <br />C W •L <br />y L� <br />W J v <br />'LO <br />Z m = <br />O Q u') - <br />M -C <br />0 LL <br />_ 00 s <br />Z M a <br />° O <br />J N <br />v Li <br />a. <br />Date: 08. 13, 13 <br />Scale: AS NOTED <br />Project Mgr: AAY <br />Drawn: DC <br />Job: 13-46 <br />Sheet <br />Tl'- <br />