Laserfiche WebLink
�9 <br />H <br />5 <br />SEE FLOOR PLAN <br />J(DIL O L O OPENINCx IN EXISTINCs CM UJ�41..L <br />SCALE: 3/8" I'-0" RM 106 SCALE: 3/8" I'-0" RM "906 SCALE: NONE <br />EXISTING BI <br />TO REMAIN <br />INTERIOR <br />NEW 4" x 3' <br />STEEL ANGI <br />EXPANSION <br />AT I6" OTC. <br />EXISTTNG BLOCK WALL <br />TO BE REMOVED <br />EXTERIOR <br />EXISTING CONCRETE <br />SLAB --\ <br />PROVIDE A MIN. /\ a <br />VAPOR BARRIER \j <br />EQUIVALENT TO <br />STEGOWRAP BELOW <br />NEW CONCRETE - TAPE \\ <br />NEW VAPOR BARRIER <br />TO EXISTING. <br />PROVIDE CLEAN COMPACTED <br />TERMITE TREATED FILL AS REQUIRED <br />NEW (2) 4" X 3 1/2" X 1/4" <br />STEEL ANGLE WITH 3/8" <br />THRU BOLTS AT 16" O.G. <br />EXISTING BLOCK <br />WALL TO REMAIN <br />REMOVE EXISTING CONC. <br />BLOCK SEE FLOOR PLAN <br />AND WINDOW SCHEDULE. <br />SAWCUT CONCRETE SLAB MIN. <br />1 1/2" DEEP AND BREAK OUT <br />EXISTING CONCRETE <br />3000 PSI CONCRETE INFILL <br />CEMENT <br />STABILIZED SAND <br />NEW PLUMBING <br />PIPING OR <br />CONDUIT AS <br />REQUIRED <br />DECK <br />EXTEND WALL TO UNDERSIDE OF <br />ROOF DECK PER U.L. DESIGN U.465 <br />STEEL CHANNEL <br />"I HOUR FIRE WALL - DO NOT PENETRATE" <br />SIGNS WITH FOUR (4) INCH LETTERING, SHALL <br />BE PLACED EVERY TEN (10) FEET MAXIMUM <br />ABOVE CEILING LEVEL ON BOTH SIDES OF <br />WALL. SIGNS MAY BE STICK ON SIGNS IN <br />CONTRASTING COLORS OR STENCILED PAINT <br />ON WALLS. <br />FIRE BLOCKING AS PER IBC 111 <br />LAY -IN ACOUSTICAL <br />OR GYPSUM BOARD <br />CEILING. <br />5/8" x 48" WIDE TYPE "X" GYPSUM WALLBOARD <br />APPLIED HORIZONTALLY OR VERTICALLY, CORNER <br />JOINTS OVER STUDS, STAGGER 16" O.G. OPPOSITE SIDES. <br />ATTACH TO STUDS AND RUNNERS WITH I" LONG TYPE "S" <br />SCREWS AT THE JOINTS 4 RUNNER CHANNELS 1/2" TO 3/4" <br />FROM EDGES OF GNU$. SCREWS SHALL BE SPACED 8" <br />O.G. ALONG EDGES OF BOARD AND 12" O.G. IN THE FIELD, <br />COVER JOINTS WITH TAPE AND JOINT COMPOUND PER <br />GA - WP - 1200. INCREASE METAL STUD THICKNESS AS <br />REQUIRED FOR PLUMBING AND ELECTRICAL. <br />FIRE BLOCKING AS PER IBC 111 <br />I SEE UL DESIGN NO. U465 I <br />R-11 BLANKET INSULATION AT <br />SOUND PROOF PARTITIONS ONLY. <br />8" GALVANIZED METAL STUDS <br />(SEE FLOOR PLAN) AT 16" O.C, 20 GA. <br />STUDS AT WALL MOUNTED EQUIPMENT <br />25 GA. GALV. STEEL CHANNEL <br />FASTEN TO SLAB AT 24" O.G. <br />FLOOR SLAB <br />104 1 TYP�C,4L FIRE RATED 10AWITION <br />101 LINTEL■ 1DETAIL J(DI 11 gAALE:1 ICUT ,/ SLA5 PATC 4 DETAIL I <br />It <br />REVEAL DETAIL <br />SCALE: 3" ■ I'-0" <br />WOOD VENEER <br />PANEL OVER <br />3/4" PLYWOOD <br />BLACK LAMINATE <br />AT REVEAL <br />LOCATIONS TYP. <br />3/4" PLYWOOD <br />Design No. U465 <br />September 27, 2005 <br />Nonbearing Wall Rating - 1 HR <br />n } <br />1. Floor and Ceiling Runners - (not shown) - Channel shaped runners, 3-5/8 in. wide (min), 1-1/4 in. legs, formed from min No. 25 MSG galv <br />steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. <br />2. Steel Studs - Channel shaped, 3-5/8 in. wide (min), 1-1/4 in. legs, 3/8 in. folded back returns, formed from min No. 25 MSG galv steel spaced <br />24 in. OC max. <br />3. Batts and Blankets* - (Optional) - Mineral wool or glass fiber batts partially or completely filling stud cavity. <br />See Batts and Blankets (BZJZ) category for names of Classified companies. <br />3A. Fiber, Sprayed* - As an alternate to Batts and Blankets (Item 3) - Spray applied cellulose material. The fiber is applied with water to <br />completely fill the enclosed cavity in accordance with the application instructions supplied with the product. Nominal dry density of 3.0 lb/ft3. <br />Alternate application method: The fiber is applied with U.S. Greenfiber LLC Type AD100 hot melt adhesive at a nominal ratio of one part <br />adhesive to 6.6 parts fiber to completely fill the enclosed cavity in accordance with the application instructions supplied with the product. <br />Nominal dry density of 2.5 IWO. <br />U S GREENFIBER L L C - Cocoon2 Stabilized or Cocoon-FRM (Fire Rated Material) <br />3B. Fiber, Sprayed* - As an alternate to Batts and Blankets (Item 3) and Item 3A - Spray applied cellulose insulation material. The fiber is <br />applied with water to interior surfaces in accordance with the application instructions supplied with the product. Applied to completely fill the <br />enclosed cavity. Minimum dry density of 4.3 pounds per cubic ft. <br />NU -WOOL CO INC - Cellulose Insulation <br />4. Gypsum Board* - 5/8 in. thick, 4 ft wide, attached to steel studs and floor and ceiling track with 1 in. long, Type S steel screws spaced 8 in. <br />OC. along edges of board and 12 in. OC in the field of the board. Joints oriented vertically and staggered on opposite sides of the assembly. <br />When attached to item 6 (resilient channels) or 6A (furring channels), wallboard is screw attached to furring channels with 1 in. long, Type S <br />steel screws spaced 12 in. OC. <br />AMERICAN GYPSUM CO - Types AG-C, AGX-I <br />BEIJING NEW BUILDING MATERIALS PUBLIC <br />LTD CO - Type DBX-1. <br />BPB AMERICA INC - Types 1, EGRG, ProRoc Type X, ProRoc Type C. <br />BPB CANADA INC - ProRoc Type C, ProRoc Type X or ProRoc Type Abuse -Resistant. <br />CANADIAN GYPSUM COMPANY - Types AR, C, IP-AR, IP-X1, IP-X2, IPC-AR SCX, SHX, WRC or WRX. <br />G-P GYPSUM CORP, SUB OF <br />GEORGIA-PACIFIC CORP - Types 5, 9, C, DAP, DD, DA, DGG, DS, GPFS6. <br />LAFARGE NORTH AMERICA INC - Types LGFC2, LGFC2A, LGFC6, LGFC6A, LGFC-C, LGFC-C/A. <br />NXTTONAL GYP9W CO - Types FSK,_F$K-C, FSK-G, FSW-C, FSW-G, FSW, FSW-3 , FSW-5. <br />PABCO BUILDING PRODUCTS L L C, DBA <br />PABCO GYPSUM - Type PG-C or PG-9 . <br />PANEL REY S A - Type PRX. <br />SIAM GYPSUM INDUSTRY (SARABURI) CO LTD - Type EX-1 <br />STANDARD GYPSUM L L C - Types FRX-6, VPBX-6, FRWRX-6, SHTGX-6, FRX-6 Exterior Gypsum Soffit Board, SG-C. <br />TEMPLE -INLAND FOREST PRODUCTS CORP - Type X, Veneer Plaster Base - Type X, Water Rated - Type X, Sheathing - Type X, Soffit - <br />Type X, TG-C. <br />UNITED STATES GYPSUM CO - Type AR, C, FRX-G, IP-AR, IP-XI, IP-X2, IPC-AR, SCX, SHX, WRC or WRX. <br />USG MEXICO S A DE C V - Type AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, WRC or WRX. <br />4A. Gypsum Board* - (As alternate to Item 4) - Nom 5/8 in. thick gypsum panels with beveled, square or tapered edges, applied vertically or <br />horizontally. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Horizontal edge joints and horizontal <br />buttjoints on opposite sides of studs need not be staggered or backed. Panels attached to steel studs and floor runner with 1 in. long Type S steel <br />screws spaced 8 in. OC when applied horizontally, or 8 in. OC along vertical and bottom edges and 12 in. OC in the field when panels are <br />applied vertically. <br />CANADIAN GYPSUM COMPANY - Types AR, C, IP-AR, IP-XI, IP-X2, IPC-AR, SCX, SHX, WRC or WRX. <br />UNITED STATES GYPSUM CO - T ype AR, C, FRX-G, IP-AR, IP-Xl, IP-X2, IPC-AR, SCX, SHX, WRC or WRX. <br />USG MEXICO S A DE C V - Type AR, C, IP-AR, IP-Xl, IP-X2, IPC-AR, SCX, SHX, WRC or WRX. <br />4B. Gypsum Board* - (As an alternate to Items 4 or 4A) - Nom 3/4 in. thick, 4 ft wide, installed as described in Item 4A with screw length <br />increased to 1-1/4 in. <br />CANADIAN GYPSUM COMPANY - Types AR, IP-AR. <br />UNITED STATES GYPSUM CO - Types AR, IP-AR. <br />USG MEXICO S A DE C V - Types AR, IP-AR. <br />5. Joint Tape and Compound - Vinyl, dry or premixed joint compound, applied in two coats to joints and screw heads; paper tape, 2 in. wide, <br />embedded in first layer of compound over all joints. As an alternate, nominal 3/32 in. thick gypsum veneer plaster may be applied to the entire <br />surface of Classified veneer baseboard. Joints reinforced. <br />6. Resilient Channel - (Optional -Not Shown) - 25 MSG galv steel resilient channels spaced vertically max 24 in. OC, flange portion attached to <br />each intersecting stud with 1/2 in. long type S- 12 panhead steel screws. <br />6A. Steel Framing Members (Not Shown)* - As an alternate to Item 3, furring channels and resilient sound isolation clip as described below: <br />a. Furring Channels - Formed of No. 25 MSG gals steel. 2-3/8 in. wide by 7/8 in. deep, spaced 24 in. OC perpendicular to studs. Channels <br />secured to studs as described in Item b. Ends of adjoining channels are overlapped 6 in. and tied together with double strand of No. 18 SWG <br />gals steel wire near each end of overlap. As an alternate, ends of adjoining channels may be overlapped 6 in. and secured together with two <br />self -tapping #6 framing screws, min. 7/16 in. long at the midpoint of the overlap, with one screw on each flange of the channel. <br />b. Steel Framing Members* - Used to attach furring channels (Item a) to studs (Item 1). Clips spaced 48 in. OC., and secured to studs with 1-5/8 <br />in. wafer or hex head Type S steel screw through the center grommet. Furring channels are friction fitted into clips. <br />PAC INTERNATIONAL INC - Type RSIC-1. <br />*Bearing the UL Classification Mark <br />UL DESIGN NO. U465 <br />SCALE: N T.S. <br />KEYED NOTES <br />OBASEBOARD - SEE FINISH SCHEDULE <br />OOPEN SPACE / KNEE SPACE BELOW COUNTER <br />OOPEN BEYOND <br />OKEYBOARD DRAWER <br />OREFRIGERATOR BY TENANT <br />OUNDERCOUNTER REFRIGERATOR BY TENANT <br />OSTAINLESS STEEL SINK - SEE PLUMBING DRAWINGS <br />OLAMINATED END PANEL <br />OLAMINATED BACKSPLASH <br />10 LAMINATED COUNTER TOP <br />11 SOLID SURFACE COUNTER TOP - SEE CABINET DETAILS AND FINISH <br />SCHEDULE. <br />12 GYPSUM WALLBOARD WRAPPED HEADER / SOFFIT - SEE <br />REFLECTED CEILING PLAN. <br />13 LAMINATED SUPPORT LEG. <br />14 FALSE LAMINATED PANEL. <br />15 3/4" WIDE x 3/4" DEEP REVEAL - SEE DETAIL 1/A3b. <br />I6 "LYNX" MOBILE CABINET PACKAGE BY TENANT. <br />11 40 INCH WIDE DUCTLESS FUME HOOD BY TENANT. <br />18 DOOR SYSTEM - SEE FLOOR PLAN AND DOOR SCHEDULE. <br />G PEW- EFRAL NOTES <br />I. SEE REFLECTED CEILING PLAN FOR ALL CEILING HEIGHTS AND <br />DECORATIVE CEILING DIMENSIONS AND DETAILS. <br />2. SUBMIT SHOP DRAWINGS TO ARCHITECT PRIOR TO FABRICATION OF <br />CABINETRY FOR APPROVAL. <br />3. SEE SHEET A4 FOR CABINET DETAILS. <br />4. SEE SHEET A5 FOR FINISH SCHEDULES AND MATERIALS. <br />REVISIONS <br />BY <br />i <br />.—.. co <br />ram. <br />►� ¢ ;0, <br />O ti <br />t- 0 <br />N <br />U <br />' E x y <br />N <br />o 2 <br />0o u N ro <br />ti > <br />0 <br />Cn <br />ti o <br />ti <br />co <br />I <br />W <br />a <br />ii <br />oo <br />6v I cv y <br />0 <br />co <br />o <br />v� <br />O <br />� � Q <br />C1. <br />C <br />U_ <br />� Z <br />O (V <br />U W Ln <br />D L. o N) <br />0-- <br />w Q <br />cn v <br />-� <br />O O <br />Q <br />O L � <br />a LLB <br />0 y <br />Lo <br />Q M L <br />°° o. <br />0 <br />a — m <br />O N <br />L. <br />J <br />LL <br />Date: 06. 03. 16 <br />Scale: AS NOTED <br />Project Mgr: AAY <br />Drawn: JDS <br />Job: 16-062 <br />Sheet <br />A3b <br />