My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39672 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39672 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:45:10 PM
Creation date
2/25/2025 9:44:54 AM
Metadata
Fields
Template:
Building Plans
Street #
39672
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 __ .J l . 1 I.d , J - -,11 <br />GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. CastAn-place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. <br />11. The exterior surface of lintels installed In exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12, Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load < 1 •O <br />Safe vertical load Safe horizontal load <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />817441B/1T8F4016/1T 8RF40OB11T 8F321B/1T <br />® © ® 8 <br />FORM dr GROUT SOLID <br />V `::*" _ R <br />N UjQ <br />p <br />#5 BAR CONE. <br />8F12-1 B/1T <br />O <br />"V" LINTEL DETAIL <br />SCALE = N.T.S. <br />E <br />F = FILLED WITH <br />GROUT / U <br />= UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />U 16- <br />BM T <br />tNOMINAL. <br />QUANTITY OF <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL - <br />HEIGHT <br />MATERIALS <br />1. c pr7MW mtels = 35DO psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 wl <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#S REBAR ALTERNATE POWERS <br />IN. (1) REQ'D <br />4 CLEAR STEEL LINTEL <br />A ° <br />r <br />4 ° .M.U. #5 REBAR AT TOP <br />a° a MIN. (1) REQ'D-� ° - d 1-1/2"CLEAR <br />4 <br />GROUT <br />D <br />° <br />n J <br />Q <br />C.M.U. <br />5 REBAR AT <br />• <br />BOTTOM OF <br />r - W <br />O_ <br />4 - <br />o <br />LINTEL CAVITY <br />wo w m W <br />w <br />\ \Q \Q <br />OTTOM <br />o ¢ CJ <br />" <br />REINFORCING <br />PROVIDED IN <br />LINTEL <br />Q ¢ r7 j <br />Z 1L o w <br />a o <br />¢ <br />N <br />D D <br />�o �. �o <br />5 REBAR AT B( <br />AS INDICATED <br />7-5/8"ACTUAL <br />" NOMINAL WIDTH <br />(VARIES) <br />tp S <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting. <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />O O <br />4'-6" LL 4'-6" LL <br />O <br />6-10" LL <br />LINTEL PLAN - ELEV-B1 <br />SCALE: Y4'=1'-0" <br />1111 <br />0 <br />O <br />* <br />OTC <br />To the best of the Engineer's knovAedge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential6th Edition. Engineer's signature and <br />seal Is on for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />9) <br />r <br />�a pp <br />p� <br />NDf � <br />Lo <br />C� <br />t-Nfco <br />p;"rn <br />LL# <br />ak <br />di <br />'7 32 <br />1L N zr� <br />N <br />LL � a <br />LL <br />a <br />y e 2 <br />y 011L SS <br />W W <br />a <br />Z0c <br />13 <br />rn <br />f <br />- <br />� <br />W <br />Cm19 5E <br />iffic T <br />m- <br />d <br />IL Z <br />rn� N O <br />�aMZ <br />O <br />z <br />N <br />O00 <br />W <br />Z N " <br />z g <br />< <br />J <br />d <br />N <br />Z <br />LL <br />D M <br />� <br />g <br />� Q <br />W•u <br />v)0 <br />C <br />C) <br />LU 0 <br />U �S <br />c g <br />Q <br />• <br />co <br />M <br />w <br />z <br />0.1 <br />Q <br />E O <br />o® <br />= <br />f- <br />'*U <br />oa <br />U V <br />Oz <br />Z <br />- <br />O E C <br />°dz a <br />z <br />r0 <br />C <br />000 <br />O <br />Ou <br />z <br />r3 <br />��O <br />W <br />Q <br />U <br />� � <br />o <br />U z <br />a <br />N W <br />� <br />C) <br />oLL <br />�_ <br />w <br />� <br />il� <br />U <br />a <br />�N <br />= <br />12 d' <br />J <br />L <br />.> <br />CM <br />U° <br />00 <br />^ <br />L.L <br />ILL <br />(D <br />o <br />r <br />O <br />C 0 <br />m <br />C7 <br />c <br />(0 <br />� <br />H <br />.o <br />E <br />T <br />a <br />•� <br />T <br />N O <br />T <br />CO <br />� <br />E <br />co <br />T <br />M <br />L0 <br />d <br />z <br />E C)H <br />E <br />` <br />a <br />0 _ <br />¢ o <br />"; <br />JOB <br />NO: <br />20-3571 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />