r <br />I <br />O <br />23 <br />m <br />rn <br />O <br />J <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or Window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FEPC <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />t <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />;Q, EXHAUST FAN/LIGHT COMBINATION <br />1.® ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />FE9 PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />D9 <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />_011-i <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />NEMA 1 <br />200 AMP <br />METER <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED _� <br />INTERSYSTEM <br />BONDING Q <br />TERMINATION PER �I <br />NEC 14, 250.94 J <br />#14 copper to IIgMs d outlets <br />#12 copper to 20 amp cMs <br />X10-2 copper to WH <br />*10-3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP DISC. <br />GFI H.B. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />u^nn nt-n c nt-no <br />lVV I rVr\ .V1 r r r <br />BUILDER <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: Y4"=1'-0" <br />C� <br />CDO <br />N <br />cg <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />Q <br />8 . N m G^p <br />N it <br />♦� <br />LQ <br />raj N N : LL <br />M ^ �' *k <br />:h! <br />32 LL a <br />M LLN U. <br />13 <br />y M a. to <br />art` as <br />0 <br />Z <br />�rnrn o <br />��8 mmo <br />i � O <br />Z; o (o <br />Z <br />IT M �03 <br />Z <br />❑❑❑ <br />W <br />c9 C <br />Z <br />Z c <br />v <br />J lh <br />a. <br />ro <br />-0 <br />V LL <br />_L <br />'U <br />N <br />LU <br />o " <br />� <br />V) <br />�V1�0 <br />o <br />M <br />M <br />= <br />� <br />W <br />3ZZ <br />ii <br />3 <br />R <br />o <br />E <br />(C <br />0 <br />z0 <br />0 <br />E <br />XVU <br />az <br />=) <br />oz <br />Zo <br />N <br />�L <br />gi <br />.0 <br />o <br />wz <br />M L4 <br />0 <br />C <br />"o <br />Z <br />Z <br />(n N <br />Qwz <br />Z <br />0Z <br />W <br />N <br />d <br />U� <br />$ <br />W LL <br />az <br />N W <br />A <br />o <br />NLL <br />z <br />a <br />�F <br />�o <br />co <br />W124 <br />zla <br />c4 3 <br />°N <br />= <br />W <br />W <br />c) <br />CM <br />00 <br />s <br />o <br />O <br />to <br />0 <br />rO <br />� <br />r <br />0) <br />= N <br />T <br />(0 <br />T <br />CO <br />LN <br />a� <br />@ <br />; r <br />M ` <br />N to <br />c <br />z <br />Z <br />E <br />£ig <br />N <br />�j <br />c <br />a <br />U � <br />Q p <br />JOB <br />NO: <br />20-3571 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />