Laserfiche WebLink
w <br />J <br />co <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />Rlr)(,F 1 INF <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + o <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + +�, <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ + <br />+ + <br />+ <br />+ + <br />+ <br />+ + <br />+++ <br />+++ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + q <br />+ + <br />+ + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + + <br />+ + <br />++ <br />+ + + <br />++++++++ <br />+ <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />BRIDGE LINE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE a <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" <br />5000s 1.8/1.7 <br />p nel <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />,�, Panels <br />2x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8"or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />90 2.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />-t i <br />1/8" gap <br />x / <br />FILL CELL STD. 90" HOOK BOND BEAM <br />w <br />STD. 90" CONT. #5 <br />CONT. #5BAR --� I HOOK BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from <br /># OF 2nd FLOOR <br />above to bearing below. <br />STUDS <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min.) Small 2" min. <br />2" max <br />gap <br />4 max. <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2 min. <br />required when indicated or 4' max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y" GAP @ TOP sides by 6". - Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION top irdsmouth cuts. <br />- Birdsmouth cuts. N.T.S. <br />- ----- - --- - -- - - - Under 2nd floor wh rmn w1 Inane <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriatefV <br />details in <br />One 10d box <br />areas=20 of high <br />or-20 sinker <br />lateral load. <br />nail each side <br />10'-0" <br />at bearing. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 000 <br />5'-0" <br />STUB -OUT FOR 0 o <br />GAS METER o <br />fV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) -12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />-P-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16- O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />V-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />1 X-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24.O.C. <br />154-4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOBNAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d1 nails at 6" o.c. <br />Provide adequate bearing <br />for each lapped joist. <br />nails SECTION INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 1003" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. <br />— <br />'7 <br />• ■ <br />• <br />►-•! <br />7=ROUND <br />A 1 ' ROUND HOLE MAY O NOT CUT HOLES <br />BE CUT ANYWHERE IN ARGER THANTHE WEB. PROVIDE AT IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />8 <br />1'-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />1'-3" <br />1'-3" <br />V-T' <br />1' 11" <br />2' 4" <br />2'-9" <br />3'-7" <br />16" joist 12 <br />7 <br />1'-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />1'-3" <br />V-9" <br />2"-4" <br />2'-11" <br />3'-7" <br />4'-2" <br />74�-9" <br />5. 4"Span <br />(ft) 16 <br />1'-0" <br />1'-1" <br />1'-2" <br />1'-2" <br />V-7" <br />2'-5" <br />S-2" <br />3'-10" <br />4' 9" <br />5'-7" <br />T-2"_._. <br />—Any <br />0 <br />i -0" <br />1'-1" <br />1'-2" <br />1'-2" <br />2'-0" <br />3'-0" <br />V-9' <br />4'-10" <br />5'-11" <br />6'-11" <br />" <br />8'-11"24 <br />1'-0" <br />1'-1" <br />i'-2" <br />1'-3" <br />2'-5" <br />3'-T' <br />4'-9 <br />5'-i0" <br />T-2" <br />8'-4" <br />10'-9" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation _ <br />Series Depth End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />- <br />BCI 6000se <br />BC16500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI600 <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190s® <br />11-7/ " <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5_16d <br />16" <br />6-16d <br />6-16d <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />GIRDER TRUSS <br />2X TOP PLATE <br />5/8" 0 <br />THRU <br />BOLT <br />2 X B.U.0 <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT—UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />In tight to top flange. SLEEVE THRU STEM7_4 <br />SEE PLAN FORFOUNDATION INFO e' <br />STEM FOUNDATION <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />oo 0.6 X Joist <br />" depth <br />oo <br />lo <br />I —JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />.a <br />r-REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A • • (WHEN <br />w/ (18)10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />III�11�11�11. <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />e <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />co Z • o • <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'4' <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />G ° / do L' <br />.a <br />e a <br />o e' ° a e <br />e <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />r�,e�r, <br />)AO, <br />4 <br />( — <br />12 �r`�✓ <br />_J <br />r <br />�� •*,' F L, O <br />ROrESs►oN <br />NN <br />S§ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />Q <br />EEro pppp <br />C 4 8 N N a <br />N N N LL <br />a; n x CD <br />to J # W <br />a <br />Q <br />rn �.- LL LL a <br />di M M W <br />u- <br />Z <br />t " W 2 <br />rr$o <br />19 <br />W <br />N G m <br />co o 2 <br />IL tL z <br />CP Ci _ <br />- NO �(n <br />10 <br />N Q J <br />Z <br />O U 1:100 <br />W <br />(D <br />z <br />(D <br />z <br />a <br />a <br />(V <br />M <br />z <br />4-J <br />a) f>3 <br />- <br />W <br />C, <br />� <br />V <br />0 <br />., , 8 <br />kn <br />�kn <br />N <br />U g <br />t <br />= <br />¢ <br />- A. <br />� <br />N� <br />W <br />M <br />J <br />LL21 <br />z <br />z <br />�yQ <br />Q <br />E <br />V <br />go <br />�z <br />18 <br />pa <br />F'•- f0 <br />x c�i< <br />O <br />UO <br />o o <br />k <br />0 E <br />N <br />w 0z <br />ao <br />it <br />¢ � <br />zN <br />.29, <br />U <br />NO <br />O <br />ow <br />Z <br />QW <br />CIO J <br />so <br />v� <br />pd <br />MillJ�'�Z <br />o <br /><<` <br />0 <br />o <br />o <br />zla <br />3 <br />124 <br />d'; <br />J <br />nL' <br />c` <br />W <br />•� <br />O <br />00 <br />O` <br />C) <br />mo <br />I... <br />E <br />qqT <br />cc <br />= o <br />to <br />+� <br />N <br />T- <br />�' <br />I �r, <br />N <br />00 <br />N <br />M <br />.— <br />M <br />T <br />01) <br />w <br />o <br />z <br />O <br />H <br />m <br />l0 <br />c <br />t_too <br />a <br />U <br />v <br />Q p <br />c <br />� <br />JOB <br />NO : <br />20-6224 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />