39724 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39724 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:45:12 PM
Creation date
2/25/2025 9:45:04 AM
Metadata
Fields
Template:
Building Plans
Street #
39724
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
870
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�NINININININI INI <br />MIN101010101 IFEI <br />7FEENNINININ101 111 <br />14'-0" RIDGE VENT <br />8"x8" SMOOTH <br />TEXTURES CORBELS <br />12 <br />�1" x 9" SMOOTH <br />5 <br />TEXTURED <br />FREEZE BAND HEEL <br />------------------- <br />12 <br />5;;e <br />-- -- —.� _ <br />a TEXTURED - <br />CEMENTICIOUS °O <br />FINISH ON C.M.U. <br />1 (TYP.) <br />I <br />----F.FL. • <br />�--+3" SMOOTH <br />TEXTURED BAND 1 <br />FRONT ELEVATION - B1 <br />SCALE: 1 /4"=V-0" <br />A. <br />W. <br />---------- <br />1' 0" <br />------ ------------------------------------ ---------------------------------------------------------------------------- -- - - - - - - - <br />- - _ HDR HGT. <br />TEXTURED <br />CEMENTICIOUS TEXTURED <br />FINISH ON C.M.U. CEMENTICIOUS <br />(TYP.) FINISH ON C.M.U. <br />(TYP.) <br />r. <br />---_F.FL. <br />+3" SMOOTH <br />TEXTURED <br />BAND <br />LEFT ELEVATION - B1 <br />N. <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />U <br />:• �� <br />To the best of the Engineers knawledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 8th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />0) <br />Q <br />�p �00 <br />C `8 8 N N it <br />N N ri <br />`C <br />di <br />7 7 W <br />Vi n -—0U-LL0.N�- W N <br />yto <br />a a <br />Z� <br />0 <br />0 <br />�LLLL <br />_ io <br />rn <br />�O4 <br />N <br />W��pjO' <br />-•W N�t0 m J <br />Z <br />� o IL <br />ccN O p N <br />te)N Cl) Q O <br />Z <br />W <br />(D <br />Z iv <br />Z <br />J <br />tNpp <br />u- <br />LL <br />4-J <br />W <br />�0 <br />— <br />LAJ <br />�N <br />U Cr <br />L <br />u <br />z_ <br />C <br />• <br />Q N <br />`I_ <br />C <br />M <br />M <br />o <br />W <br />L <br />EE O <br />zo <br />sz <br />>Q <br />k! <br />co <br />H <br /><. <br />i0 <br />00 <br />Wa <br />00 <br />�U <br />zN <br />i <br />�o <br />ado <br />m0 <br />z <br />r0 <br />Ca <br />:3 3 <br />N <br />ZZ <br />N O <br />op O <br />21ri <br />N <br />�m <br />81z <br />Z <br />o <br />W <br />k;3 <br />w0� <br />CD <br />�p�pl�tIw <br />� <br />ZIQ <br />0 N <br />J <br />�N <br />> <br />Las <br />m <br />W <br />O <br />4) <br />00 <br />O <br />C) <br />/�' m <br />W <br />C <br />O <br />`.�no <br />Eca <br />d. <br />r <br />= o <br />O) <br />et O <br />LO <br />oo <br />E <br />cM <br />o <br />a <br />E .. <br />'a m <br />c <br />0 � <br />¢ o <br />� <br />JOB <br />NO: <br />20-6224 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />