My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39724 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39724 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:45:12 PM
Creation date
2/25/2025 9:45:04 AM
Metadata
Fields
Template:
Building Plans
Street #
39724
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
870
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />114 copper to lights a outlets <br />NEMA 1 10 #12 copper to 20 amp ckts <br />200 AMP <br />10 010-2 copper to WH <br />Do A`10-3 copper to Dryer <br />METER <br />r <br />or Oro SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 J <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric cede, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window, are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The Width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />� wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />R4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />I) <br />RECESSED LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FANLIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />HD <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />@ <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />.a <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGiH-IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />WP GFI DISC. DEDICATED RECEPTACLE <br />H.B. FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />\ 3 GFI '7-F]AC PAD --- <br />RANGE <br />in <br />\� PENDANT AS <br />\PER SPECS <br />— / .C. SWI C <br />SAFE I I D.W. IO SINKW/• <br />y� DISP <br />PA 7V GFI L ---- — -- ----- <br />-- - _ <br />r----- — GFI <br />I <br />I <br />U.C. OUTLET <br />I <br />I <br />I <br />U.C. OUTLET <br />I ROUGH -IN FOR FOR DW <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I \ <br />'I FAMILI RM <br />I <br />I <br />I <br />I / <br />I <br />I ' <br />I <br />I I <br />I <br />I � <br />O I <br />D') <br />\ ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PREE--WIRE <br />A <br />OWNER'S SUITE <br />I <br />0. <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ \ <br />LIGHT PRE -WIRE <br />I <br />GFI \ <br />.. BEDROOM 'i\)\L� <br />OPT. <br />REF. m m <br />I III III <br />® \1.0611.= <br />inmffis <br />RECEPT. <br />FOR ALARM <br />SYSTEM — <br />r <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />BED 600_� , <br />x C.M <br />1.3 <br />-1 @ 44" <br />A.F.F. <br />— — — — — — — — — — — — <br />/� —� I <br />n <br />� I <br />I I 1 1 <br />I 11 I <br />I <br />GFI @ 44" � I <br />A.F.F. <br />I <br />GFI FOR <br />GAR. DOO� <br />GFI <br />I <br />2 CAR GARAGE <br />I <br />I <br />I <br />I <br />O I <br />v H VERIFY LOCATION <br />IRRIGATION <br />ELECTRICAL PANEL <br />ltlllr_� FI @ 44" A.F.F._ <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />GFI <br />/ ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />/ LIGHT PRE -WIRE <br />BEDROOM 4 <br />ENTRY <br />ELECTRICAL PLAN — ELEV—Bal <br />SCALE: Y4'=V-0" <br />0 <br />N <br />0 <br />N <br />0 <br />rn <br />0 <br />To the best of the Engineers knowledge. Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential Bth Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />81, <br />N <br />(� <br />N C N LL <br />n at <br />ai <br />a <br />(ANN LL' LL a <br />4rf 52 W N <br />d W <br />JLL <br />Z <br />2 <br />LL SS G 1/' <br />t&S 0oo <br />j an m �' <br />02 <br />Z <br />00 N ° N <br />N <br />W <br />Q U 0 J <br />OU ❑❑❑ <br />0 <br />Z N ch <br />Z <br />z <br />rz � <br />N <br />Z <br />f0 <br />t.t_t <br />O <br />W s <br />N <br />U <br />• <br />mQ <br />C2 , <br />O <br />M <br />01 <br />W <br />Q <br />J <br />m rc <br />go <br />Qo <br />QO <br />i U <br />U <br />Z <br />Z <br />to <br />(n C <br />� <br />J� <br />m0 <br />O~~LL <br />QZ <br />N <br />N <br />� w <br />8 <br />wLL <br />U <br />a <br />�Z <br />W <br />v <br />°LL <br />� <br />o <br />Z <br />Mj <br />CID <br />i <br />a <br />3 <br />^L <br />W <br />O <br />O <br />00 <br />O <br />Q <br />U <br />rr2RR <br />V <br />° <br />m <br />G <br />cc <br />CN <br />CN <br />0 <br />a) <br />E <br />° TT <br />M <br />° <br />Z <br />Z <br />E O <br />B :3 <br />` <br />` <br />o- <br />U .°i <br />Q <br />JOB <br />NO: <br />20-6224 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.