Laserfiche WebLink
INDEX OF DRAWINGS <br />SHEET DESCRIPTION <br />SHEET <br />No. <br />CS COVER SHEET <br />1 FLOOR PLAN <br />2 INTERIOR ELEVATIONS <br />3.1 EXTERIOR ELEVATIONS <br />3.2 EXTERIOR ELEVATIONS <br />F1 FOAM DETAILS <br />4 ELECTRICAL PLAN <br />5 ROOF PLAN <br />6 FOUNDATION PLAN <br />7 ROOF FRAMING PLAN <br />8 LINTEL DETAILS <br />SN STRUCTURAL NOTES <br />ABBREVIATIONS SN1 DETAILS <br />S3M MONO DETAILS <br />AB or A.B. Anchor Bolt FIX or FXD Fixed PWDR or Pwd. Powder Room <br />ABV or Abv. Above FLR or Fir. Floor RA or R/A or R.A. Return Air S4 DETAILS <br />AC or A/C Air -Conditioner FLR SYS or Fir Sys Floor System RAD or Rad. Radius S5 DETAILS <br />ADJ orADJ. Adjustable FOM or F.O.M. Face Of Masonry RAG or Rag. Return Air Grill <br />r AFF or A. F.F. Above Finished Floor FP or F.P. Fireplace REC or Rec. Recessed SS RETROFIT DETAILS <br />AHU or A.H.U. Air Handler Unit FIR DR French Door RECEPT Receptacle D1 SECTIONS &DETAILS <br />ALT or ALT. Alternate FRT Front REF or Ref. Refrigerator <br />BC Base Cabinet FT or Ft. Foot/ Feet REINF Reinforcing WP WATERPROOFING DETAILS <br />F BF Bifold Door FTG or Fig. Footing READ or Req'd. Required PA1.0 PRODUCT APPROVAL NUMBERS <br />BK SH or Bk Sh BookShelf FXD GL Fixed Glass RM or Rm. Room <br />BILK orBLK. Block GALVorGaly. Galvanized RNDorRnd. Round PA1.1 PRODUCT APPROVAL NUMBERS <br />BLW or BLW, Below GC or G.C. General Contractor RO or R.O. Rough Opening <br />BM or Bm. Beam GFI or G.F.I. Ground Fault Interrupter RS, R/S, R/SH or R&S Rod and Shelf PA1.2 PRODUCT APPROVAL NUMBERS <br />BOT or Bot. Bottom GT or G.T. Girder Truss SD or SD. Smoke Detector PA1.3 PRODUCT APPROVAL NUMBERS <br />BP or B.P. Bypass (door) GYP BD or Gyp. Bd. Gypsum Board SGD Sliding Glass Door <br />BRG or BRG. Bearing HB Hose Bibb SH or Sh. Shelves <br />C Carpet HDR or Hdr. Header SHT Sheet <br />CAB Cabinet HGT or Hgt. Height SHWR or Shwr. Shower <br />CIR or Cir. Circle HH or H.H. Hand Held (plumbing faucet) SL or S.L. Side Lights <br />CJ or C/J Control Joint HORIZ Horizontal SPECS or SPECS. Specifications <br />CLG or Clg. Ceiling HS Hard Surface (flooring) SPF or S.P.F. Spruce Pine Fir <br />CMU Concrete Masonry Unit ILO In Lieu Of SO FT or SF or S.F. Square Foot (feet) <br />or <br />� COFF or Coff. Coffered or Tray Ceiling INSUL or Insul. Insulation SQ or Sqq . Square <br />COL or Col. Column INT or Int. Interior STO Storage <br />COMP or Comm. Community KS or K. or KlWall Kneewall SW or S.W. Shear Wall <br />a� COMP or Comp. Compressor KS or K.S. Knee Space SYP or S.Y.P. Southern Yellow Pine <br />CONN or CONN. Connection LAUN or Laun. Laundry TB Towel Bar <br />CCont. Continuous LAV or Lay. Lavatory TEMP or Temp. Tempered <br />CTT or or C.T. Ceramic Tile LF or L.F. Linear Ft. THIKN or Thik'n. Thicken <br />D or D. Dryer LL Lintel Length TOB or T.O.B. Top of Block <br />DB Door Bell LT Laundry Tub TOM or T.O.M. Top of Masonry00 <br />❑ ❑ ❑ ❑ ❑ ❑ ❑ <br />o DBL or Dbl. Double MAS or Mas. Masonry TOP or T.O.P. Top of Plate <br />o DCF Decorative Cementitious Finish MAX or Max Maximum TP Toilet Paper Holder <br />a DEC or Dec. Decorative MC Medicine Cabinet TR Towel Ring <br />DED or Ded. Dedicated (outlet) MFR or Mfr. Manufacturer TRANS WDW or Trans. Transom Window <br />' of DIA or Dia. Diameter MGT Management (room) TYP or Typ. Typical <br />R= DISP or Disp. Disposal MIN or Min Minimum UC or u.c. Under Counter <br />DIST or Dist. Distance MIR or Mir. Mirror UCL Under Cabinet Lighting <br />Q DMF Decorative Masonry Finish ML or M.L. Microlam UNO or U.N.O. Unless Noted Otherwise <br />M DS or D.S. Drawer Stack MONO or Mono Monolithic V or v. Valve (shower or tub/shower) <br />DTL Detail MW or MICRO or Micro. Microwave VB Vanity Base <br />DV or D.V. Dryer Vent NTS or N.T.S. Not to Scale VERT or Vert Vertical <br />DVP or D.V.P. Diverter Valve (plumbing) OE or O.E. Owner's Entry VL or V.L. Versalam <br />DW or D.W. Dishwasher OPNG or Opn'g. Opening VTR or VTE Vent through Roof / Exterior <br />= EA or Ea. Each OPT or Opt. Optional W or w Washer <br />L ELEC or Elec. Electrical PC Pull Chain W/ or w/ With <br />o ELEV or Elev. Elevation PED or Ped. Pedestal WA or W.A. Wedge Anchor <br />J EQ Equal PH Phone WC or WIC or W.C. Water Closet (toilet) <br />EW or E.W. Each Way PKT or Pkt. Pocket (Door) WD or Wd Wood <br />EXP or Exp, Expansion PL or P,L. Parallam WDWHDRorWDW. HDR. Window Header <br />N EXT or Ext. Exterior PLF Pounds per linear foot WH or W.H. Water Heater <br />fi > FBC Florida Building Code PLNT SHLF or Pit. Sh. Plant Shelf WIC or W.I.C. Walk-in Closet <br />FDN or Fdn. Foundation PLT HT or Pit. Ht. Plate Height WM or W.M. Wall Mounted (plumbing fixture) <br />FG Fiberglass Shower Pan PSF Pounds per square foot WP Water Proof(in) MEAN ROOF 15 FT. HIGH TYPICAL <br />9 ( ) P 9 <br />i FIN Finished PT or P.T. Pressure Treated WS Water Softener FOR SINGLE STORY HOMES <br />FIN FLR or FF or Fin. Fir. Finished Floor PW or P.W. Pre -wire WWF Welded Wire Fabric (Mesh) <br />MEAN ROOF 30 FT. HIGH TYPICAL <br />PLAN REVISIONS <br />FOR 2 STORY HOMES <br />}` DATE VERSION DESCRIPTION <br />o THIS DRAWING AND DESIGN IS VALID <br />08-20-15 1.0 NEW BASE PLAN FOR 12 MONTHS AFTER THE DATE IT <br />IS SIGNED AND SEALED OR WHILE <br />CURRENT CODE IS VALID <br />12-8-15 2.0 FRAME -WALK REVISIONS CODE REFERENCES ARE SUMMARIES <br />OF CODE SECTIONS. <br />12-28-17 3.0 2017 FBC UPDATES SEE FBCR (CURRENT VERSION) FOR <br />COMPLETE CODE INFORMATION. <br />r.� <br />0 <br />02-21-18 4.0 ADDED GRADE BEAM 150 MPH ENG. Notice to Builder & All Subcontractors <br />v It is the intent of Designer/Engineer listed in the titleblock of these <br />o documents that these documents be accurate, providing Licensed <br />08-27-19 4.1 ENG. REVIEW FOR 150—C MPH Professionals clear information. Every attempt has been made to <br />prevent error. The Builder and all subcontractors are required to <br />review all the information contained in these documents, prior to <br />09-20-19 4.2 ADD 8'-8" ELEV. FOR TR EVE STA the commencement any work. The DesignerEngineeraro not <br />a <br />responsible for any plan <br />n errors, omissions,or misinterpretations <br />undetected and not reported to the Designer / Engineer prior to <br />o construction. All construction MUST be in accordance to the <br />e o information found in these documents. Any questions regarding <br />3 the information found in these plans should be directed to our <br />0 Office at (407) 880-2333 immediately. No backcharges will be <br />14considered for reimbursement by the Designer/Engineer without <br />advanced notification and approval by the Designer/Engineer. <br />CN <br />\ , �^,� � W` tit+IE <br />t'rH PREVAILING�� Payments will be made in accordance to the terms of the <br />ALL WORK SHALL~ � � <br />c' DES FLORID <br />A 13',1� agreement. <br />o NATIONAi- Control of Construction Site: <br />-i-t THE. %,e <br />o ANC The Designer/Architect and engineer of record (EOR) have no <br />9RM4ANCES control over the construction site and shall not be responsible in <br />o any manner for control of the construction site including, but not <br />Nlimited to, scheduling and sequencing of work, jobsite safety, and <br />ventilation of the building and thereby shall not be responsible for <br />{ the indoor air quality, or the effects thereof, for any reason <br />ULUwhatsoever. The Designer/Architect and FOR has no duty to <br />RE, <br />NT protect, without limitation, the residence, construction site, <br />t `:+(.;°�w x materials, or equipment, from moisture, mold, fungus, fire, theft, <br />���� 1 91 <br />vandalism, trespass, or any other peril or condition, at any time, <br />P�a ✓ expressly including, but not limited to, the period of time before <br />construction, during the construction of the project, or after <br />m construction and the Designer/Architect and FOR has no duty to <br />D take any action or preventive measures to protect such property <br />o against any such peril at any time for any reason. <br />s N <br />I� I <br />P <br />1 1_; F ,, _a.lr'IA,w:,ui 11,mardlm.Mlun Lifi:.,H,. 1 AJ I I I ll 11 _F--T-----T­-1 II Ii i <br />fX����R <br />�a<:q�143�t1f <br />K <br />�o1 <br />e <br />rn: <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition, Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />o � , E3 00 <br />N 00 <br />N 3t <br />9 <br />0 <br />U) <br />r * - LL <br />�nrn0) _ Lu <br />�r, a LL a <br />m LL i� a air <br />zo <br />me pQY F— <br />o m O <br />�. <br />CV m <br />(2 <br />W <br />m rn ¢ a <br />0 <br />Z <br />rLL <br />00 o <br />M Z <br />O <br />M <br />Z <br />N U J <br />Q <br />U ❑0❑ <br />W <br />04 Q <br />Z N M <br />O <br />Z N <br />z o � <br />J <br />0. � <br />E3 <br />U) N <br />N <br />M <br />z <br />ty <br />0 0 <br />C6 <br />w <br />Q) <br />t/1 <br />to <br />O <br />� <br />r cn <br />U <br />r- J pE <br />0 3 <br />t <br />mI <br />JW <br />U o <br />co <br />s <br />o <br />cc' <br />J <br />w <br />co <br />z <br />Z <br />Z <br />_J <br />LL <br />E <br />o <br />o0 <br />2 <br /><� <br />i? o <br />E U <br />� <br />Z® <br />oa <br />ro <br />O E <br />CC'JD <br />R 80 <br />a'- <br />i <br />� <br />a Z <br />L <br />wo <br />6 <br />C <br />< <br />U <br />U� <br />Z <br />Z <br />m <br />Q W <br />z <br />to <br />U <br />o�� <br />LL <br />a <br />�Z <br />0 <br />aW <br />O <br />t9 <br />�r <br />a x <br />V <br />ZOR <br />° : <br />�N <br />a <br />= <br />>� <br />m <br />W <br />\ <br />/ <br />1= <br />m <br />0 <br />U <br />00 <br />� <br />r <br />C <br />> <br />O <br />C) <br />U <br />1..� <br />E o <br />d. <br />rco <br />o <br />N <br />r <br />00 L0 <br />Ltd <br />00 <br />0 <br />ai <br />m <br />r <br />C17 <br />0 <br />Z <br />Z <br />E O <br />ri <br />a <br />;_ <br />0 <br />U <br />a a? <br />Q cc <br />c <br />JOB <br />NO: <br />20-6226 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />C S <br />