My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39783 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39783 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:03:44 AM
Creation date
2/25/2025 9:45:33 AM
Metadata
Fields
Template:
Building Plans
Street #
39783
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1462
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 000 <br />T-0" <br />STUB -OUT FOR 1'-Oo o <br />" <br />GAS METER 0 -' o <br />U <br />O f <br />CV 0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'41 <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />1514" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking + <br />1/8" gap ° <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />FILL CELL STD. 90' HOOK BOND BEAM <br />W <br />w <br />STD. 90° CONT. #5 <br />BAR T. #5 I HOOK �F BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/min. Small 2" min. <br />2"n } gap <br />max. � 4 max. <br />Q <br />Clinch nails <br />when <br />possible <br />Tight fit L <br />2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series I Depth I End Intermediate <br />BCI5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI 6000s® <br />BCI6500su <br />9-112" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />- Hangers with side nailing. <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />5/8"[1 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) - <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />LC <br />TYPICAL SIMPSON MGT TO <br />BUILT—UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />i <br />' SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />BLOCKING PANEL, INTERIOR <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking Vertical load transfer =1900plf max. along bearing wall TYPICAL SIMPSON META12 / TYPICAL SIMPSON MTS <br />BEARING Use 3" (10d) nails at 6" o.c. Required on interior walls : - for vertical load transfer Plumbing META12 TSS INSTALLATION / HTS INSTALLATION <br />Vertical load transfer =1900 plf max along load bearing wall. Load bearing walls when load bearing - for lateral support when joists <br />Load bearing wall must stack meet over wall, or wall stacks directly over wall or <br />over squash=20 blocks and beam below Load bearing wall must stack over <br />* <br />Non -stacking walls blocking and wall or beam below.* <br />require additional wall or beam below.* Joist <br />consideration. Check <br />local building When joists meet over wall, provide <br />code for appropriate 11/16" 1 314" minimum bearing for each. I -Joist can be offset PLUMBING LINE <br />details in One 10d box up to al l avoid <br />areas=20 of high kor--20 sinker vertical plumbing TOP (2) #5's x 4'4' <br />3" max CENTERED @ PIPE PVC OR SCH40 SLEEVE <br />lateral load. nail each side A/C CHASE 4" PVC PENETRATION <br />at bearing. JOISTS OFFSET JOISTS •7 SLEEVE THRU STEM <br />N.T.S. WALL d a A <br />a a <br />Provide adequate bearing Use 10dx3" nails at kwalls <br />�I I I �I 11=—I— — ° e: a a'. <br />for each lapped joist. •• �— ' <br />blocking panel *Non -stacking — _ r i — _ , . • -`r <br />00 <br />Squash block 10d nails SECTION INT. BRG. WALL require additional consideration. j�r —I_ _ FINI GRADE <br />(2x4 minimum) @ _ _ _ _ — — <br />Bearing wall, Versa -Lam LVL or N.T.S. _— III_— �—�I I -- I I� •° Ef1ITI-rI—�7IT I <br />Glulam Beam rI rI <br />�r <br />TI=1Tf='— <br />rrr <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />rl 6"" A %" ROUND HOLE MAY J q 6" 6"^ <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1 2" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />'-,,Install tight to top flange. <br />Joist hanger <br />y \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is !laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />p depth <br />I —JOISTS BUCKETS <br />N.T.S. <br />SLEEVE THRU STEMS <br />SEE PLAN FOR----'°. , .. <br />FOUNDATION INFO <br />STEM FOUNDATION <br />l <br />REINF. SEE PLAN <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />N <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION <br />a - e d <br />'C A <br />•' a A 'A <br />io Z • ° • <br />A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />7 Q C .d A .. <br />°' A ea G <br />a <br />a .. a A. a M� <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />C) <br />r <br />f <br /><P/'� <br />R,����111lf19ilff <br />?P� <br />g• O <br />F � S <br />+i <br />8.119lt <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />N <br />Qw <br />�E IDF- <br />- <br />O M S N <br />a-o <br />N m J LL <br />0 <br />7 co N vt LL W <br />�N <br />�040o JaY <br />B <br />CaLL[L awl <br />J O <br />Z_y <br />m c O <br />v <br />Ir <br />W <br />'' N (p K J <br />Z <br />IL <br />U) Cj a <br />N M Z W SQ O <br />pV U vVi <br />Z <br />W <br />❑ ❑ ❑ <br />z N C7 <br />o o <br />z (o <br />z <br />J <br />N <br />M <br />to <br />z a <br />C9 0 <br />a--+ <br />U <br />O—� <br />N <br />r.ir o <br />v <br />w <br />— E <br />m i •....., <br />.o <br />0 <br />c <br />co <br />w <br />co <br />coo <br />J <br />n ¢ <br />Z <br />U_ <br />QE <br />O <br />E <br />N <br />�o <br />g0 <br />S <br />N <br />z9 <br />I-- <br />E <br />O C <br />x o <br />U <br />a� <br />az <br />c) H <br />p <br />°z <br />wz <br />�� L <br />< p <br />.Z <br />m o <br />O <br />z <br />QJ <br />J <br />a ° <br />z z <br />to <br />Z <br />go <br />o= <br />a <br />mw <br />w< <br />>° <br />o <br />c <br />V <br />is <br />a <br />°3 <br />NO <br />>Lo <br />6L <br />L <br />m <br />Al <br />W <br />� <br />._ <br />0 <br />O <br />CD <br />Q <br />Y <br />O <br />C) <br />/•► <br />s <br />/�\ m <br />C0 <br />(!� <br />O <br />M N <br />Cif <br />v/ <br />00 <br />LO <br />O <br />T <br />E <br />c N <br />M <br />6 <br />z <br />O <br />0 <br />m <br />E <br />U J <br />o ai <br />Q 0 <br />J <br />JOB <br />NO: <br />20-8093 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.