My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39783 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39783 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:03:44 AM
Creation date
2/25/2025 9:45:33 AM
Metadata
Fields
Template:
Building Plans
Street #
39783
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1462
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance With UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI LIL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501,17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />PE5W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />I <br />O <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THE'RMOSTAT <br />]M <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />(✓ T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />MAIN <br />0 <br />200 amp <br />150 amp <br />copper to lights & outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />UNDERGROUND jDisconnect <br />POWER CO. FEED ,.. 1 <br />INTERSYSTEM 4 Bare Cu Ground •V, qi I, <br />BONDING r, #4 GROUNDING WIRE V <br />TERMINATION PER <br />NEC 14, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />C.M <br />PA �O I CAFE <br />\ <br />III 211 <br />I VI, MTh <br />PLUMBING RISER_ <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />OWNER'S SW� ITE <br />T <br />/ ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE / <br />U M-1 <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />■A■■■■■■1 <br />I / <br />I <br />I I <br />I <br />I <br />I <br />I <br />I ` <br />I j\ <br />FAMILY RM <br />I � � <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />I LIGHT PRE -WIRE <br />I <br />U.C. OUTLET <br />I FOR DW <br />I <br />U.C. OUTLET <br />I <br />I <br />I <br />GFI Le <br />/ GFI C—---------- GFI <br />�— —� <br />I I O <br />Fr <br />I D.W. I <br />L — — —J <br />/ / I INK k DIS \ <br />it T— <br />IPENDANT AS \ <br />/ PER SPECS \ <br />/ <br />/ - \ <br />/ <br />/ to <br />db <br />WP H.B. <br />GFI DISC. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />W IRRIGATION <br />VERIFY LOCATION FGFI <br />W H <br />D ELECTRICAL PANEL <br />O I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR <br />GAR. DOOh <br />GFI <br />GFI @ 44" <br />A.F.F. <br />I <br />I I <br />I <br />I 11 <br />I <br />/ I <br />L— — — — — — — — — — — — <br />GFI @ 44" <br />4k A.F.F. <br />11 ■�■■■■■= III <br />M <br />II II <br />BEDR(f%D'10M 3) <br />I;. <br />I� :ROUGH -IN• - <br />■■■■■�LIGHT PRE -WIRE <br />1■ <br />I� .. <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=1'-0" <br />Iul <br />s <br />Q <br />�0 <br />Q <br />CV <br />0 <br />N <br />GO <br />N <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />CD <br />g <br />o MN 8 N � J <br />Q <br />oc @ 4r�7 J LL <br />•j to N u , W <br />N <br />N <br />r` J Lu LL <br />M c u- a Y <br />13o <br />-mom Oo <br />�Z/ <br />W <br />J <br />5 'gip N (O LL OJ13 <br />Z <br />LL0 W <br />co - 0 <br />a <br />Z <br />N M Z X N 0 <br />d U U D N <br />W <br />❑ ....1 ❑ <br />CD� <br />o'D <br />z <br />M <br />� <br />z <br />� <br />U <br />O <br />N <br />W o <br />Ly N <br />t;a <br />RigW <br />U <br />J <br />— E <br />i <br />Z .; <br />U oo o <br />c � d <br />• <br />N o <br />c <br />m <br />o <br />W <br />1 <br />ai E <br />o <br />E: U <br />=o <br />Wo <br />� <br />> <br /><s <br />z® <br />wa <br />rd <br />X❑R. <br />❑❑o <br />❑ <br />Z <br />1Q.1 to <br />a< <br />wo <br />❑� <br />wW <br />! L <br />Qp <br />m� <br />to <br />N <br />❑ <br />J <br />m <br />G <br />N <br />o <br />5o <br />, <br />a Z <br />�w <br />W <br />U <br />�� <br />oii <br />�k <br />�� <br />J <br />� <br />o <br />< <br />w¢ <br />CIS <br />�° <br />ou <br />0 <br />2 O <br />= <br />to <br />a; <br />W <br />ca <br />3 <br />._ <br />0 <br />o <br />O <br />A/ <br />LL <br />CD <br />�\ <br />a <br />Y <br />> <br />o <br />O <br />a� m <br />o <br />�..i <br />E N <br />T <br />-Q <br />co O <br />O <br />00 <br />T= <br />O <br />N <br />T <br />T <br />E <br />c <br />M <br />Z <br />Z <br />E O <br />d <br />E <br />U -1 <br />q 0 <br />JOB <br />NO: <br />20-8093 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />