My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39889 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39889 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 4:49:28 AM
Creation date
2/25/2025 9:45:42 AM
Metadata
Fields
Template:
Building Plans
Street #
39889
Location
Harmon Grove Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
1752
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W P <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />H9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />own <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150AI200A INDOOR <br />PANEL CENTER <br />10, #14 copper to lights & outlets <br />NEMA 1 01 #12 copper to 20 amp ckts <br />150 AMP/ <br />200 AMP #10-2 copper to WH <br />01 #10-3 copper to Dryer <br />METER <br />M&INT <br />0 r /0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND DisconneL#4GROUNDING <br />POWER CO. FEED <br />Bare Cu Ground <br />INTERSYSTEM <br />BONDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 14, 250.94 Y CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />III 2^ <br />VI`1 "IA I <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />(� _ _ IRRIGATION _ _ _ _ <br />'1 GFI ---- 1 VERIFY LOCATION GFI @ 44" A.F.F. <br />I - ! i L I Q <br />ELECTRICAL PANEL I I <br />O I I I <br />II I I I <br />W.I. C <br />ITE �fil�' <br />OWNER'S S� / - -_---. - ! I' 1 I I I <br />--- \ 2 CAR GARAGE <br />12 <br />GFI FOR I I I <br />/ ROUGH -IN FOR GAR. DOOM I I <br />/ OPT. CLG. FAN/ I CaF1 I I I <br />LIGHT PRE -WIRE -_ GFI @ 44" <br />/ <br />A.F.F. 1 <br />I I I I I <br />------------J r-�--i I I I <br />S.D. / / dVP <br />tqpL' ' I <br />C.M 0 T. OPT. I 1 1 I I I <br />N, li I I I <br />Uri_ <br />I I I <br />L------------- <br />I I <br />GFI @ 44" <br />I ` T <br />A.F.F. <br />FAMILY RM -- <br />01 1 I <br />i <br />ENTRY <br />ROUGH -IN FOR / / �� —�T - WID <br />OPT. CLG. FAN/ - GFI <br />LIGHT PRE -WIRE <br />1------- <br />U.C. OUTLET <br />t3 _ 3-- <br />FORDW--------------- ---------- <br />S.D. <br />S.D. <br />U.C. OUTLET , G <br />rM <br />1 <br />1 OPT. � <br />=GFI ----- i REF- / I FI <br />-= -� BEDROOM 2 S.D. { <br />PA I�O CAFE GFI ------ GF` -- /� / \ O I <br />�\ 1 BEDFWOOM 31 - 1 BEDROOM 4 <br />TIHGFI <br />/ I j OUGH-IN FOR �/ /� / I \ ROUGH -IN FOR <br />i ;F8 INKwIDIS OPT. CLG. FAN/ <br />OPT. CLG. FAN/ <br />VIM F4�C.-SwfTn}i' LIGHT PRE -WIRE <br />TIPENDANT tSP <br />AS QQ IsAt_ LIGHT PRE -WIRE I O \ <br />ER SPECS \ -� ROUGH -IN FOR I \ <br />OPT. CLG. FAN/ I <br />L0 \ / LIGHT PRE -WIRE <br />CPAD- <br />i 3 GFI • GFI I <br />111111111 lip <br />DEDICATED RECEPTACLE <br />WP H. <br />FOR MICROWAVE RANGE <br />GFI DISC. HOOD PER SPECS <br />ELECTRICAL PLAN — ELEV—Al <br />N <br />0 <br />N <br />cfl <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief,' <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building <br />Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />Eo <br />OD <br />nJpp <br />C <br />N 0 <br />.0LL <br />LL <br />w <br />WrC <br />jr-,aFA <br />�0 <br />LLat <br />Lu <br />C103 <br />m LL LL <br />-1 <br />. N <br />li ul S <br />O <br />Z <br />r.0 @ v <br />�7 �� N� p <br />m O J <br />W <br />Z <br />02pjO' <br />a <br />N �Z�rnO <br />Q <br />o <br />U 3 co <br />Z <br />W <br />v <br />000 <br />0 M <br />z oN <br />z <br />z <br />Q <br />J — <br />rZ <br />N <br />— N <br />M <br />zC21 <br />(� w m p a <br />U <br />0 <br />m <br />w $ <br />V) C N <br />�l� 5 <br />RigW <br />= L <br />c U) <br />Q N 0 <br />r• <br />o <br />W <br />CAM <br />a <br />Z <br />a <br />1= 0ca V <br />w j <br />_® <br />c) <br />Ica <br />X0 <br />00 <br />ZE <br />O <br />N <br />as <br />'Z-az <br />afLL0 <br />0� <br />�W <br />.2 <br />0 <br />z Z <br />Z <br />N <br />N J <br />mm <br />i7m <br />QW <br />�N <br />N 3 <br />n <br />0� <br />w0 <br />z <br />50 <br />Yw <br />W <br />U <br />12 <br />�� <br />a° <br />(00(pp <br />�l <br />zl4 <br />Ei <br />U 3 <br />0124 <br />= <br />a <br />mil/ <br />O <br />L <br />^' <br />� <br />O <br />O <br />T <br />W <br />N <br />; <br />L.J.. <br />O <br />C m <br />CO <br />T <br />O <br />O <br />= <br />N <br />r <br />•T <br />I <br />00 <br />00 <br />N <br />T <br />00 <br />T <br />E <br />Z <br />CN <br />M <br />o <br />Z <br />Z <br />E C) <br />a <br />E <br />U <br />Q <br />4ic <br />p <br />JOB <br />NO: <br />21-2032 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />