Laserfiche WebLink
3 <br />•v <br />m <br />0 <br />cn <br />`w <br />C <br />N <br />x <br />C1 <br />O <br />0 <br />J <br />N <br />I <br />m <br />rn <br />it <br />C <br />N <br />'s <br />0 <br />0 <br />J <br />O <br />O <br />I <br />i <br />0 <br />co <br />lY <br />CD <br />i <br />CT <br />3 <br />a <br />0 <br />E <br />0 <br />x <br />O <br />J <br />/!f <br />r7 <br />0 <br />U <br />i <br />ti <br />U <br />O <br />i <br />a <br />0 <br />_o <br />0 <br />LZ <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANELCENTER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />UNDERGROUND Dis <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER 71 <br />NEC 14, 250.94 ---/// <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />copper to lights & outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 410 SER Alu <br />4 Bare Cu Ground V/ F <br />ry� <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11.In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />P'4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />I-D <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TV <br />TELEVISION (OPTIONAL) <br />T�2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />urn_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />Ci J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />WIP H.B. <br />GFI DISC. <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />IJ L.LII I,/'11 LLJ f1Lli Gf" r /'1l�LC <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />VERIFY METER <br />LOCATION WITH <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=1'-0" <br />CV <br />0 <br />CV <br />Cfl <br />CV <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />W <br />v E <br />O OM S <br />n <br />N roo� it <br />O N <br />N tT <br />J <br />LL <br />V <br />,G O� <br />O 2 <br />� c0 C <br />t�A <br />'� J ' <br />7t LL w <br />wq N <br />Q <br />r� r-- r-L <br />l)M V <br />LL w a_ <br />ll Y <br />c�iL <br />J LL' <br />w w <br />d <br />Z <br />L <br />LU <br />(6 <br />NLu <br />¢ a <br />W <br />rog�rn <br />p <br />rn m Z <br />J 11 <br />� to O <br />NIL OU <br />U to <br />Z <br />W <br />❑❑❑ <br />z N <br />o g <br />Z N <br />15-11 <br />z o � <br />U)V) <br />N <br />M <br />z a <br />o <br />aj <br />+-� u, <br />fCS u l <br />U <br />O <br />N <br />�N <br />W o <br />w <br />i� <br />) <br />U <br />1� <br />U O N <br />C D <br />0 <br />N <br />144 � <br />o <br />CIDz <br />w <br />c0 <br />J <br />00 <br />h� <br />u_ <br />Q E <br />o <br />E <br />o�F <br />o <br />aS <br />Z® <br />v <br />co <br />— <br />O E <br />0 <br />x3 <br />U <br />aQ <br />z <br />¢o <br />u° <br />o 1 <br />-1 <br />� <br />0 <br />ttW <br />L <br />M <br />C <br />z <br />o Y <br />mo <br />N <br />J <br />hm <br />a <br />¢w <br />z <br />cn <br />cl)w <br />Qo <br />U <br />manOUG <br />� <br />U <br />� <br />�o <br />a <br />mw <br />�� <br />o' <br />o <br /><< <br />o <br />O <br />o. <br />a <br />O� <br />0 <br />c O <br />= <br />> Lo <br />O <br />rn <br />m <br />0 <br />L <br />n1 <br />� <br />0 <br />' <br />U <br />'Ct <br />Q <br />X> <br />Y <br />o <br />0 <br />CL <br />m <br />� <br />o <br />^C: <br />ET <br />T <br />� <br />r <br />V, <br />= <br />Or <br />E <br />C ^�' <br />` V <br />iri N <br />0 <br />m <br />Z <br />E O <br />E <br />c <br />a <br />U <br />Q 0 <br />JOB <br />NO: <br />21-2030 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />