My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6606 Stadium Dr (4)
Zephyrhills
>
Building Department
>
Building Plans
>
6606 Stadium Dr (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:48:47 PM
Creation date
2/25/2025 9:46:33 AM
Metadata
Fields
Template:
Building Plans
Street #
6606
Location
Stadium Dr
Contractor
Wallace Associates
Building Plans - Permit #
15912
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_. - ,-. __ _ � __— - - 1 I — �I <br />LUMINAIRE SCHEDULE <br />TYPE <br />MANUFACTURER <br />CATALOG NO. <br />VOLTAGE <br />LAMPS <br />WATTAGE <br />MOUNTING <br />DESCRIPTION <br />NOTES <br />F1 <br />METALUX <br />2GR8-232A125- <br />120 <br />2-F32T8 <br />61 <br />CEILING RECESSED <br />2' X 4' FLUORESCENT STATIC <br />UNV-EB81-U <br />GRID TROFFER WITH ACRYLIC <br />LENS <br />F1A <br />METALUX <br />2GR8-232A125- <br />120 <br />2-F32T8 <br />61 <br />CEILING RECESSED <br />2' X 4' FLUORESCENT STATIC <br />UNV-EB81- <br />GRID TROFFER WITH ACRYLIC <br />BAL140OLPACTD <br />LENS AND A SELF-CONTAINED <br />EMERGENCY BATTERY PACK <br />F2 <br />METALUX <br />2RDI-217RP- <br />120 <br />2-F17T8 <br />34 <br />CEILING RECESSED <br />2' X 2' FLUORESCENT DIRECT/ <br />UNV-EB81-U <br />INDIRECT LUMINAIRE WITH <br />CENTER -MOUNT LAMPS <br />F2A <br />METALUX <br />2RDI-217RP- <br />120 <br />2-F17T8 <br />34 <br />CEILING RECESSED <br />2' X 2' FLUORESCENT DIRECT/ <br />UNV-EB81- <br />INDIRECT LUMINAIRE WITH <br />BAL140OLPACTD <br />CENTER -MOUNT LAMPS AND A <br />SELF-CONTAINED EMERGENCY <br />BATTERY PACK <br />F3 <br />HALO <br />PD6H132E-62HWB <br />120 <br />1-32W TTT <br />36 <br />CEILING RECESSED <br />6" FLUORESCENT DOWNLIGHT <br />WITH A SPECULAR CLEAR <br />REFLECTOR <br />F4 <br />SHAPER <br />658-15-W-L1/827- <br />120 <br />LED FURNISHED <br />11 <br />WALL MOUNTED AT <br />DECORATIVE LED WALL SCONCE <br />UNV-COLOR BY AIA <br />WITH FIXTURE <br />6'-0" AFF TO C/L <br />WITH LUMINOUS SHIELD <br />F5 <br />ALL -PRO <br />ET40OLVAT-ERT403LV <br />120 <br />SOW 12V MR16 <br />50 <br />CEILING RECESSED <br />4" LOW VOLTAGE DOWNLIGHT <br />WITH A SPECULAR CLEAR <br />REFLECTOR <br />F6 <br />TERON LIGHTING <br />TLNIW-F226Q- <br />120 <br />2-26W QE <br />56 <br />WALL MOUNTED <br />EXTERIOR ARCHITECTURAL <br />FLUORECENT LUMINAIRE <br />F7 <br />TERON LIGHTING <br />TLNW-F142X- <br />120 <br />1-42W TBX <br />48 <br />WALL MOUNTED <br />EXTERIOR ARCHITECTURAL <br />DL <br />FLUORECENT LUMINAIRE, <br />DOWNLIGHT ONLY <br />F8 <br />MCGRAW-EDISON <br />TLM-400-MP-MT- <br />120 <br />1-40OW PULSE <br />452 <br />POLE MOUNTED <br />EXTERIOR ARCHITECTURAL <br />5S-FG-DP-FF-DM <br />START METAL <br />SITE LIGHTING LUMINAIRE WITH <br />HALIDE <br />TYPE V SEGMENTED DISTRIBUTION <br />AND FLAT GLASS LENS <br />®� <br />ALL -PRO <br />APX7R <br />120 <br />LED <br />1 <br />CEILING SURFACE <br />LED EXIT SIGN. NUMBER OF FACES <br />AND CHEVRONS AS INDICATED <br />ON DRAWINGS. <br />DESIGN GENERAL NOTES <br />1. VOLTAGE DROP CALCULATIONS HAVE BEEN PERFORMED AND COMPLY WITH FLORIDA BUILDING CODE 13-413. FEEDER <br />CONDUCTORS HAVE BEEN SIZED FOR A MAXIMUM VOLTAGE DROP OF 2 PERCENT AT DESIGN LOAD AND BRANCH <br />CONDUCTORS HAVE BEEN SIZED FOR A MAXIMUM VOLTAGE DROP OF 3 PERCENT AT DESIGN LOAD. DURING <br />CONSTRUCTION ALL 208/120 VOLT BRANCH CIRCUITS THAT EXCEED 120 FEET IN LENGTH FROM THE ELECTRIC PANEL <br />TO THE DEVICE SHALL REQUIRE THE CONDUCTORS TO BE UPSIZED TO THE NEXT NOMINAL SIZE SO AS NOT TO EXCEED <br />THE MAXIMUM VOLTAGE DROP. <br />2. THE INSTALLATION SHALL COMPLY WITH ALL LAWS IN EFFECT APPLYING TO ELECTRICAL INSTALLATIONS, THE FOLLOWING <br />CODES ARE APPLICABLE: <br />1. NFPA 70: NATIONAL ELECTRICAL CODE (2008) <br />2. NFPA 72: NATIONAL FIRE ALARM CODE (2007) <br />3. NFPA 101: LIFE SAFETY CODE (2009) <br />4. NFPA 241: STANDARD FOR SAFEGUARDING CONSTRUCTION ALTERATION AND DEMOLITION <br />OPERATIONS (2004) <br />5. FLORIDA BUILDING CODE 2010 <br />GENERAL ELECTRICAL CONSTRUCTION NOTES: <br />1. PROVIDE TYPED DIRECTORY CARDS UNDER PLASTIC DOORS OF BRANCH CIRCUIT PANEL - <br />BOARDS NEW AND EXISTING AFFECTED UNDER THE SCOPE OF THIS PROJECT. DIRECTORIES <br />SHALL INDICATE DEVICES BEING SERVED INCLUDING SPACE NUMBERS IN WHICH DEVICES OR <br />FIXTURES ARE LOCATED. SPACE NAMES AND NUMBERS SHALL MATCH THE GRAPHICS <br />INSTALLED IF DIFFERENT FROM THE SPACE NAMES AND NUMBERS ON THE DRAWINGS. <br />2. ELECTRICAL CONTRACTOR SHALL REFER TO THE ELECTRICAL SPECIFICATIONS FOR <br />ADDITIONAL DESIGN STANDARDS. THE ELECTRICAL SPECIFICATIONS ARE A BINDING PART <br />OF THE CONSTRUCTION DOCUMENTS. WHENEVER A CONFLICT OCCURS BETWEEN THE <br />CONTRACT DOCUMENTS AND THE SPECIFICATIONS, THE ELECTRICAL CONTRACTOR SHALL CALL <br />THE ENGINEER TO CLARIFY. <br />3. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CODE COMPLIANT PENETRATIONS FOR ALL <br />NEW CONDUITS ENTERING/EXITING FIRE RATED WALLS. REFER TO ARCHITECTURAL DRAWINGS <br />FOR LOCATIONS OF ALL FIRE RATED WALLS. ALL EXISTING NON -CODE COMPLIANT ELECTRICAL <br />PENETRATIONS WITHIN THE PROJECT SCOPE (INCLUDING BUT NOT LIMITED TO EXISTING <br />ELECTRICAL ROOMS, AND CORRIDORS) SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR <br />TO CORRECT. <br />GENERAL NOTES <br />1. AN EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED IN ALL ELECTRICAL <br />RACEWAYS AND SHALL BE SIZED IN ACCORDANCE WITH N.E.C. ARTICLE 250-122. <br />2. DISREGARD SYMBOLS AND ABBREVIATIONS WHICH ARE NOT USED ON CONTRACT <br />DOCUMENTS <br />3. LEGEND SYMBOLS SHOWN WITH AN "E" NEXT TO THE SYMBOL INDICATES EXISTING <br />DEVICE TO REMAIN. <br />ABBREVIATIONS <br />4. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REMOVE AND RE -INSTALL <br />AFF <br />ABOVE FINISHED FLOOR <br />ANY LIGHT FIXTURES OR CEILING MOUNTED DEVICES THAT NEED TO BE TEMPORARILY REMOVED, <br />AHU <br />- AIR HANDLING UNIT <br />DUE TO THE RENOVATION OF ANY MECHANICAL AND ELECTRICAL SYSTEMS. THE CONTRACTOR <br />BFG <br />C <br />- BELOW FINISHED GRADE <br />CONDUIT <br />SHALL VERIFY ALL AREAS OF POTENTIAL CEILING RE -WORK PRIOR TO BID. <br />CLG <br />CEILING MOUNTED <br />C/L <br />- CENTERLINE <br />5. THE ELECTRICAL CONTRACTOR (E.C.) SHALL VISIT THE SITE PRIOR TO BID AND ALLOW FOR <br />CU <br />- CONDENSING UNIT <br />EXISTING CONDITIONS IN HIS BID. THE E.C. SHALL ALSO MATCH THE EXISTING COLOR SCHEME <br />CW <br />DN <br />- COOL WHITE <br />DOWN <br />OF ELECTRICAL DEVICES ALREADY ESTABLISHED ON SITE AND CONFIRM WITH OWNER. <br />EDH <br />-ELECTRIC DUCT HEATER <br />EF <br />EXHAUSTFAN <br />6. COORDINATE WITH OWNER OR OWNER'S SELECTED VENDOR PRIOR TO ROUGH -IN FOR EXACT <br />ENCL <br />ENCLOSURE <br />LOCATIONS OF SPECIAL PURPOSE OUTLETS DEDICATED TO SPECIFIC EQUIPMENT. VERIFY <br />EWC <br />ELECTRIC WATER COOLER <br />REQUIRED NEMA CONFIGURATION OF ALL SUCH OUTLETS. <br />EX <br />EX <br />ELECTRIC WATER HEATER <br />-EXPLOSION PROOF <br />FCU <br />- FAN COIL UNIT <br />7. INCLUDE A GREEN -INSULATED GROUNDING CONDUCTOR SIZED PER N.E.C. TABLE 250.122 <br />FHP <br />- FRACTIONAL HORSEPOWER <br />WITH ALL BRANCH CIRCUIT CONDUCTORS CONNECTED TO LIGHTING FIXTURES, RECEPTACLES <br />FLA <br />- FULL LOAD AMPERES <br />AND MECHANICAL OR OTHER DEVICES. <br />G <br />GFI <br />- GROUND <br />-GROUND FAULT INTERRUPTER <br />GWH <br />- GAS WATER HEATER <br />HID <br />- HIGH INTENSITY DISCHARGE <br />HOA <br />- HANDS OFF AUTOMATIC <br />HORIZ - HORIZONTAL <br />LW - LOW WHITE <br />HP - HORSEPOWER, HEAT PUMP <br />HVAC - HEATING, VENTING <br />AIR CONDITIONING <br />1B <br />- JUNCTION BOX <br />LRA <br />- LOCKED ROTOR AMPERES <br />MCB <br />- MAIN CIRCUIT BREAKER <br />MLO <br />- MAIN LUGS ONLY <br />N <br />- NEUTRAL <br />NIL <br />- NIGHTLIGHT <br />OB <br />- OUTLET BOX <br />PB <br />- PULL BOX, PUSHBUTTON <br />PS <br />- PAY STATION <br />RECEPT- RECEPTACLE <br />SF <br />SUPPLY FAN <br />SPEC <br />SPECIFICATIONS <br />TL <br />- TWISTLOCK <br />TTB <br />- TELEPHONE TERMINAL BOARD <br />VERT <br />- VERTICAL <br />WP <br />- WEATHERPROOF <br />WW <br />WARM WHITE <br />XFMR <br />TRANSFORMER <br />ELECTRICAL LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />® <br />FLUORESCENT LIGHT FIXTURE <br />SEE FIXTURE SCHEDULE <br />CaFLUORESCENT <br />LIGHT FIXTURE WITH A SELF- <br />CONTAINED EMERGENCY BATTERY PACK <br />SEE FIXTURE SCHEDULE <br />"�j <br />FLUORESCENT, INCANDESCENT OR <br />HID LIGHT FIXTURE <br />SEE FIXTURE SCHEDULE <br />FLUORESCENT, INCANDESCENT OR HID <br />LIGHT FIXTURE WITH A SELF-CONTAINED <br />EMERGENCY BATTERY PACK <br />SEE FIXTURE SCHEDULE <br />FLUORESCENT, INCANDESCENT OR <br />HID LIGHT FIXTURE <br />SEE FIXTURE SCHEDULE <br />FLUORESCENT, INCANDESCENT OR HID <br />LIGHT FIXTURE WITH A SELF-CONTAINED <br />EMERGENCY BATTERY PACK <br />SEE FIXTURE SCHEDULE <br />FLUORESCENT STRIP LIGHT FIXTURE <br />SEE FIXTURE SCHEDULE <br />FLUORESCENT STRIP LIGHT FIXTURE WITH A <br />SELF-CONTAINED EMERGENCY BATTERY PACK <br />SEE FIXTURE SCHEDULE <br />® <br />EXIT LIGHT FIXTURE. (SHADED <br />QUADRANT) INDICATES FACE(S) <br />OF FIXTURES <br />SEE FIXTURE SCHEDULE <br />EXIT LIGHT FIXTURE. (SHADED <br />QUADRANT) INDICATES FACE(S) <br />OF FIXTURES <br />SEE FIXTURE SCHEDULE <br />LIGHT TRACK WITH LIGHT FIXTURES <br />SEE FIXTURE SCHEDULE <br />% 01 <br />CHANDELIER INCANDESCENT <br />SEE FIXTURE SCHEDULE <br />EMERGENCY BATTERY PACK LIGHT <br />FIXTURE <br />SEE FIXTURE SCHEDULE <br />Q <br />REMOTE EMERGENCY LIGHT HEAD <br />SEE FIXTURE SCHEDULE <br />�❑ <br />PARKING LOT OR ROADWAY LIGHT <br />FIXTURE <br />SEE FIXTURE SCHEDULE <br />QO <br />SIDEWALK BOLLARD LIGHT FIXTURE <br />SEE FIXTURE SCHEDULE <br />FLUORESCENT, INCANDESCENT OR HID <br />ADJUSTABLE LIGHT FIXTURE <br />SEE FIXTURE SCHEDULE <br />PADDLE TYPE CEILING FAN <br />SEE FIXTURE SCHEDULE <br />® <br />EXHAUST FAN <br />SEE MECHANICAL <br />DRAWINGS <br />s <br />SWITCH, SINGLE POLE <br />46" AFF TO C/L <br />S a <br />SWITCH, SINGLE POLE (SUBSCRIPT <br />INDICATES CONTROLLING SWITCH) <br />46" AFF TO C/L <br />S 2 <br />SWITCH, DOUBLE POLE <br />46" AFF TO C/L <br />S 3 <br />SWITCH, THREE-WAY <br />46" AFF TO C/L <br />S 4 <br />SWITCH, FOUR-WAY <br />46" AFF TO C/L <br />S L <br />SWITCH, LOW VOLTAGE <br />46" AFF TO C/L <br />SD <br />SWITCH, DIMMER <br />46" AFF TO C/L <br />S F <br />SWITCH, FAN <br />46" AFF TO C/L <br />So <br />OVERRIDE SWITCH, SEE DRAWINGS <br />FOR ADDITIONAL INFORMATION <br />46" AFF TO C/L <br />S P <br />SWITCH, WITH PILOT LIGHT <br />46" AFF TO C/L <br />ST <br />SWITCH, WITH TIMER <br />46" AFF TO C/L <br />S m <br />SWITCH, MOTOR RATED <br />46" AFF TO C/L <br />Ss <br />SWEEP CONTROL SWITCH, SEE DETAIL AND <br />SPECIFICATIONS FOR ADDITIONAL INFORMATION <br />46" AFF TO C/L <br />0_ <br />20 AMP SINGLE RECEPTACLE <br />18" AFF TO C/L <br />EWC 0-- <br />20 AMP SINGLE RECEPTACLE FOR <br />ELECTRIC WATER COOLER <br />COORDINATE WITH <br />GENERAL CONTRACTOR <br />20 AMP DUPLEX RECEPTACLE <br />18" AFF TO C/L <br />20 AMP DUPLEX RECEPTACLE <br />44" AFF TO C/L <br />OR AS NOTED <br />20 AMP QUADPLEX RECEPTACLE <br />18" AFF TO C/L <br />♦ <br />20 AMP GFCI DUPLEX RECEPTACLE <br />18" AFF TO C/L <br />WP <br />20 AMP GFCI DUPLEX RECEPTACLE <br />WITH WEATHERPROOF COVER <br />18" AFF TO C/L <br />20 AMP DUPLEX RECEPTACLE <br />(TOP HALF SWITCHED) <br />18" AFF TO C/L <br />IG <br />20 AMP ISOLATED GROUND DUPLEX <br />RECEPTACLE (ORANGE DEVICE) <br />18" AFF TO C/L <br />IG <br />20 AMP RECEPTACLE LATED GROUND ( <br />(ORANGE DEVICE) DUPLEX <br />44" AFF O C/L OR <br />AS NOTED <br />IG <br />20 AMP ISOLATED GROUND DUPLEX <br />RECEPTACLE (ORANGE DEVICE) <br />AND 20 AMP. DUPLEX RECEPTACLE <br />18" AFF TO C/L <br />20 AMP GFCI DUPLEX RECEPTACLE <br />44" AFF TO C/L OR <br />AS NOTED <br />125/25OV., 3P., <br />3W. MP., I (DRYER) <br />46" AFF EO C/L OR <br />OT <br />Ivu <br />lavo <br />COMBINATION MAGNETIC <br />MOTOR STARTER <br />STARTER SIZE <br />60" AFF TO TOP <br />�p <br />MANUAL MOTOR STARTER <br />STARTER SIZE <br />60" AFF TO TOP <br />MOTOR CONNECTION <br />AS NOTED <br />OS <br />SHUNT -TRIP BUTTON IN A KEYED <br />LOCK ENCLOSURE <br />46" AFF TO C/L OR <br />AS NOTED <br />ELECTRIC DUCT HEATER <br />SEE MECHANICAL <br />DRAWINGS <br />® <br />DOOR CHIME <br />84" AFF TO C/L <br />DOORBELL PUSHBUTTON <br />46" AFF TO C/L <br />Q <br />THERMOSTAT <br />SEE MECHANICAL <br />DRAWINGS <br />1 <br />MOTORIZED DAMPER <br />SEE MECHANICAL <br />DRAWINGS <br />( 1O <br />KEYED NOTES <br />- <br />PANELBOARD UNDER 250 VOLTS <br />72" AFF TO TOP <br />® <br />PANELBOARD OVER 250 VOLTS <br />72" AFF TO TOP <br />QT <br />DRY TYPE TRANSFORMER <br />SEE TRANSFORMER <br />SCHEDULE <br />8 <br />AUTOMATIC TRANSFER SWITCH <br />72" AFF TO TOP <br />QOO D <br />SD-SUPPLUCT Y RKREDTURN ETECT0R <br />DUOCTWORK UNTED 0 MECH. <br />TIME SWITCH <br />WALL MOUNTED <br />® <br />CONTACTOR <br />WALL MOUNTED <br />ELECTRICAL LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />-{�+-- <br />BRANCH CIRCUIT CONCEALED ABOVE <br />CEILING OR IN WALL. SLASH MARKS <br />INDICATE NUMBER OF CONDUCTORS. <br />SHORT SLASHES INDICATE PHASE <br />CONDUCTOR OR SWITCH LEG. LONG <br />SLASH INDICATES NEUTRAL CONDUCTOR. <br />SHORT HOOKED SLASH INDICATES <br />ISOLATED GROUND (EQUIPMENT <br />GROUND REQUIRED BUT NOT SHOWN). <br />TWO CONDUCTORS PLUS GROUND <br />REQUIRED (UNLESS OTHERWISE NOTED <br />OR MARKED). <br />-}�- <br />BRANCH CIRCUIT WITH ISOLATED GROUND <br />-�x--. <br />HOME RUN TO PANELBOARD <br />--- <br />BRANCH CIRCUIT CONDUIT CONCEALED <br />IN SLAB OR UNDERGROUND <br />- - - - <br />BRANCH CIRCUIT CONDUIT EXPOSED <br />-W- <br />SURFACE MOUNTED DECORATIVE <br />RACEWAY (EQ.: WIREMOLD) <br />-LY- <br />LOW VOLTAGE WIRING INSTALLED IN <br />CONDUIT <br />-LS- <br />LIFE SAFETY BRANCH CIRCUIT <br />_C_ <br />CRITICAL BRANCH CIRCUIT <br />-EQ- <br />EQUIPMENT BRANCH CIRCUIT <br />-� <br />CONDUIT RUN UP <br />-� <br />CONDUIT RUN DOWN <br />EQUIPMENT CONNECTION USING <br />FLEXIBLE CONDUIT <br />SO <br />PAGING/MUSIC SPEAKER <br />CEILING RECESSED <br />PAGING/MUSIC SPEAKER <br />WALL MOUNTED, COORDINATE <br />V� <br />WITH ARCH. DWGS. <br />0 <br />VOLUME CONTROL SWITCH <br />46" AFF TO C/L <br />CCTV CAMERA <br />AS INDICATED ON <br />DRAWINGS <br />QM <br />CCTV MONITOR <br />SITTING ON COUNTER <br />Q <br />DOOR CONTROL KEY PAD <br />46" AFF TO C/L <br />04 <br />SPECIAL PURPOSE RECEPTACLE <br />AS INDICATED ON <br />DRAWINGS <br />O <br />20 AMP DUPLEX RECEPTACLE <br />FLUSH WITH FINISHED <br />INSTALLED IN FLOOR BOX <br />FLOOR <br />20 AMP DUPLEX RECEPTACLE <br />MOUNTED TO UNDER <br />FLOOR DUCT <br />20 AMP DUPLEX RECEPTACLE <br />MOUNTED FLUSH WITH <br />FINISHED CEILING <br />0 <br />OUTLET, JUNCTION OR PULL BOX <br />AS NOTED <br />FRAME SIZE <br />30 3 <br />DISCONNECT SWITCH <br />60" AFF TO TOP <br />FUSE SIZE <br />MAGNETIC MOTOR STARTER <br />60" AFF TO TOP <br />STARTER SIZE <br />® <br />OCCUPANCY SENSOR <br />SEMI -FLUSH MOUNTED <br />IN THE CEILING <br />TELEPHONE, TELEVISION AND COMPUTER LEGEND <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />p <br />TELEPHONE/DATA OUTLET FOR DESK <br />18" AFF TO C/L <br />MOUNTED EQUIPMENT <br />C <br />TELEPHONE/DATA OUTLET FOR COUNTER <br />SEE ARCHITECTURAL <br />TOP MOUNTED EQUIPMENT <br />INTERIOR ELEVATIONS <br />D <br />TELEPHONE OUTLET FOR DESK <br />18" AFF TO C/L <br />MOUNTED TELEPHONE <br />W <br />TELEPHONE OUTLET FOR WALL <br />54" AFF TO C/L <br />MOUNTED TELEPHONE <br />C <br />TELEPHONE OUTLET FOR COUNTER TOP <br />SEE ARCHITECTURAL <br />TELEPHONE <br />INTERIOR ELEVATIONS <br />P <br />TELEPHONE OUTLET FOR PUBLIC PAY <br />54" AFF TO C/L <br />TELEPHONE <br />v <br />TELEVISION OUTLET <br />18" AFF TO C/L <br />UNLESS OTHERWISE INDICATED <br />Q D <br />COMPUTER OUTLET FOR DESK MOUNTED <br />18" AFF TO C/L <br />COMPUTER EQUIPMENT <br />Q C <br />COMPUTER OUTLET FOR COUNTER TOP <br />SEE ARCHITECTURAL <br />COMPUTER EQUIPMENT <br />INTERIOR ELEVATIONS <br />® <br />TELEPHONE TERMINAL BOARD "TTB" <br />WALL MOUNTED <br />T.T.B. <br />m <br />TELEPHONE TERMINAL CABINET "TTC" <br />72" AFF TO TOP <br />T.T.C. <br />m <br />COMPUTER TERMINAL CABINET "CTC" <br />72" AFF TO TOP <br />C.T.C. <br />® <br />CABLE TELEVISION TERMINAL BOARD <br />WALL MOUNTED <br />C.T.T.B. <br />1'CTTB" <br />ELECTRICAL INDEX <br />SHEET <br />DESCRIPTION <br />EO <br />LEGEND AND LIGHTING FIXTURE SCHEDULE <br />El <br />SITE PLAN - LIGHTING AND POWER <br />E2 <br />FLOOR PLAN - DEMOLITION - POWER AND LIGHTING <br />E3 <br />ROOF PLAN - DEMOLITION - POWER <br />E4 <br />FLOOR PLAN - LIGHTING <br />E5 <br />FLOOR PLAN - POWER AND COMMUNICATIONS <br />E6 <br />ROOF PLAN - POWER <br />E7 <br />ELECTRICAL DETAILS <br />E8 <br />POWER DISTRIBUTION RISER DIAGRAM AND PANEL SCHEDULES <br />E9 <br />SPECIFICATIONS <br />E10 <br />SPECIFICATIONS <br />Ell <br />SPECIFICATIONS <br />A1 <br />REVISIONS <br />BY <br />Ql 03.10.15 <br />RM <br />! u o0 <br />I�r tD M <br />• v M C") <br />¢.nti G <br />0 <br />o ti <br />ti <br />x u <br />. / C: a <br />U <br />U � N <br />ti > <br />y ti <br />ti <br />� � c <br />0 <br />N <br />m <br />Uj A <br />���dyyy A <br />Z O <br />U p; <br />O <br />U <br />ZO WUt14 <br />rn <br />�Aa � <br />O O rn <br />LZ .0 <br />C O <br />0 <br />0 <br />V <br />o 0 o m 00 <br />W <br />Z <br />oO <br />�Qnm <br />mm <br />Le) Ln U a.arc <br />W <br />^ n v <br />n n a <br />W <br />�m <br />0LL <br />Zr <br />3 <br />3 <br />a <br />v <br />_ <br />0 <br />m <br />Z <br />W <br />]C <br />61 N <br />Y N <br />D <br />00 <br />�^ m <br />t N <br />f= � <br />0 LL; <br />r^n <br />Z cn a <br />c <br />c o <br />`o c <br />Q � r <br />L LO -R V <br />.I <br />\\ <br />V A <br />w Ln N <br />r1ir iu O 0 <br />a a <br />— u <br />QVUw(7Q <br />U C' <br />— Z <br />Z 0 <br />J J <br />U � � <br />J m p _J >• <br />-0 <br />Q � t <br />C <br />cUWEvi� <br />U <br />o =0 <br />> L4- 0 <br />i <br />U <br />C �O Ns0- <br />Q J 0 N <br />Q to <br />U_ <br />OO 0 <br />W <br />LL_ <br />Date: 12. 19. 14 <br />Scale: AS NOTED <br />Project Mgr: ARK <br />Drawn: BK <br />Job: 14-137 <br />Sheet <br />EO <br />f0 THE BEST OF THE ENGINEERS KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE -SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTER 553.79 AND CHAPTER 633, FLORIDA STATUTES. <br />
The URL can be used to link to this page
Your browser does not support the video tag.