Laserfiche WebLink
1 1 . <br />MATERIAL LEGEND <br />CONSTRUCTION NOTES <br />GENERAL NOTES <br />BUILDING CODE INFORMATION <br />INDEX OF DRAWING S <br />EARTH/ FILL <br />I. INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILING SHALL <br />I. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITION OF <br />APPLICABLE CODES AND STANDAIaDB <br />TI TITLE SHEET <br />BE IN ACCORDANCE WITH A5TM E84. ALL FINISH MATERIALS SHALL <br />THE NATIONAL FIRE CODE "FLORIDA BUILDING CODE," "FLORIDA <br />T2 ABBREVIATION SHEET <br />MEET A CLASS "B" INTERIOR FINISH RATING IN EXIT AND EXIT <br />PLUMBING CODE," "FLORIDA MECHANICAL CODE," "NATIONAL <br />THE FLORIDA BUILDING CODE, 2010 EDITION <br />BRICK <br />a . <br />n CONCRETE <br />STUCCO, CEMENT PLASTER, LIGHTWEIGHT CONCRETE <br />CMU- LARGE: SCALE <br />ACCESS AREA. CLASS "C" ELSEWHERE. <br />2. ALL EXIT DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE <br />WITHOUT THE USE OF A KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT. <br />MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS SHALL NOT <br />BE USED. <br />3" ALL GLAZING WITHIN A 24 INCH ARC OF DOORS WHOSE BOTTOM EDGE <br />IS LE55 THAN 60 INCHES ABOVE THE FLOOR AND GLASS BELOW 18" <br />AP.F. AND ALL GLAZING IN DOORS SHALL BE SAFETY GLASS, <br />TEMPERED GLASS OR ACRYLIC PLASTIC SHEET. PER F15C-2406.1 <br />ELECTRICAL CODE," AND ALL OTHER APPLICABLE LOCAL, STATE, <br />AND FEDERAL CODES AND ORDINANCES, AND ALL AUTHORITIES <br />HAVING LOCAL JURISDICTION. <br />2. THE GENERAL CONTRACTOR SHALL PERFORM ALL WORK IN <br />ACCORDANCE WITH THE CURRENT EDITION OF THE "GENERAL <br />CONDITIONS OF THE CONTRACT FOR CONSTRUCTION" AIA DOCUMENT <br />A201. <br />3. THE CONTRACTOR SHALL, UPON DISCOVERY, GIVE WRITTEN NOTICE <br />TO THE ARCHITECT OF ANY MATERIALS, EQUIPMENT, OR DESIGN <br />FEATURES WHICH HE BELIEVES TO BE INADEQUATE OR UNSUITABLE, IN <br />•BUILDING <br />s PLUMBING <br />•MECHANICAL <br />s ENERGY CONSERVATION <br />• ELECTRICAL <br />SITE PLAN <br />QI DI DEMOLITION DEMOLITION FLOOR PLAN <br />03 DEMOLITION ROOF PLAN <br />D4a DEMOLITION EXTERIOR ELEVATIONS <br />1 4b DEMOLITION EXTERIOR ELEVATIONS <br />L�� <br />ASI ARCHITECTURAL SITE PLAN <br />A 2 ARCHITECTURAL SITE DETAILS <br />A63 BOUNDAIRY SURVEY <br />2012 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION <br />FLORIDA FIRE PREVENTION CODE 2010 EDITION <br />NFPA 101 LIFE SAFETY CODE FLORIDA EDITION <br />NATIONAL ELECTRICAL CODE 2008 EDITION <br />CMU- SMALL SCALE <br />4. OBJECTS PROTRUDING FROM WALLS WITH THEIR LEADING EDGES <br />VIOLATION OF LAWS, ORDINANCES, OR RULES AND REGULATIONS OF <br />BETWEEN 21" AND 80" ABOVE THE FINISHED FLOOR SHALL <br />PROTRUDE NO MORE THAN 4" INTO WALKS, HALLS, CORRIDORS, <br />THE AUTHORITIES HAVING JURISDICTION OVER THE WORK, AND OF <br />ANY NECESSARY ITEMS OR WORK OMITTED FROM THE DRAWINGS. <br />LI LANDSCAPE PLAN <br />2010 ADA STANDARDS FOR AGGESSIBLE DE51GN <br />METAL -LARGE SCALE <br />PASSAGEWAYS, OR AISLES. OBJECTS MOUNTED AT OR BELOW 21" <br />ABOVE FINISHED FLOOR MAY NOT PROTRUDE ANY AMOUNT. FREE <br />USE ONLY SKILLED CRAFTSMEN, <br />4. ALL SUBCONTRACTORS SHALL&S <br />LIFE SAFETY <br />USE AND OCCUPANCY CLASSIFICATION <br />METAL OR SHEET METAL -SMALL SCALE <br />O O <br />WOOD FINISH <br />STANDING OBJECTS MOUNTED ON POST OR PYLONS MAY OVERHANG <br />12". PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF <br />AN ACCESSIBLE ROUTE OR MANEUVERING SPACE. <br />5. PROVIDE DEADWOOD BLOCKING WITHIN WALL CAVITIES AT <br />EXPERIENCED IN THE WORK OF THEIR TRADE, TO ENSURE FIRST <br />CLASS WORKMANSHIP. ANY WORK NOT EQUAL TO BEST TRADE <br />STANDARDS SHALL BE REMOVED AND REPLACED AT NO <br />. <br />ADDITIONAL COSTSHOULD ANY SUBCONTRACTOR REFUSE TO <br />REMOVE AND REPLACE UNSATISFACTORY WORK, THE CONTRACTOR <br />I la FLOOR PLAN <br />I lb ENL'4RGED PI-'�N`3 <br />I DIMENSIONED FLOOR PLAN <br />BUSINESS OCCUPANCY-GROUP'B' <br />CLA551FICATION OF WORK PER FEBC EXISTING BUILDING SECTION 405 - ALTERATION LEVEL 3 <br />LOCATIONS INCLUDING, BUT NOT LIMITED TO, WALL MOUNTED <br />MAY REMOVE AND REPLACE IT, AND C"ARGE THE COST TO THE <br />I REFLECTED CEILING PLAN <br />WOOD BLOCKING CONTINUOUS <br />CABINETRY, FIRE EXTINGUISHER CABINETS, TOILET ACCESSORIES, <br />GRAB BARS, WALL STOPS, ETC.. ISGA. GALV, FLAT METAL MAY BE <br />USED IN LOCATIONS APPROVED BY ARCHITECT. <br />SUBCONTRACTOR. <br />5. IT IS THE GENERAL CONTRACTOR'S SOLE RESPONSIBILITY TO <br />DETERMINE ERECTION PROCEDURE AND SEQUENCE TO ENSURE THE <br />A3b CEILING DETAILS <br />ROOF PLAN <br />EXTERIOR ELEVATIONS <br />GENERAL BUILDINGHEIGHTS AND AREAS <br />WOOD BLOCKING INTERMITTENT <br />6. ANY CONCEALED COMBUSTIBLE SPACE IN WHICH BUILDING <br />SAFETY OF PEOPLE AND OF THE BUILDING AND ITS COMPONENT <br />EXTERIOR ELEVATIONS <br />TABLE 503 <br />MAX, ALLOWEDPROVIDED <br />PLYWOOD <br />MATERIALS HAVING A FLAME SPREAD INDEX GREATER THAN CLASS <br />ARE EXPOSED SHALL BE DRAFTSTOPPED AS FOLLOWS: <br />6.L EVERY EXTERIOR AND INTERIOR WALL AND PARTITION SHALL <br />FIRESTOPPED AT EACH FLOOR LEVEL, AT THE TOP STORY <br />CEILING LEVEL, AND AT THE LEVEL OF SUPPORT FOR ROOFS <br />PARTS DURING CONSTRUCTION, THIS INCLUDES, BUT IS NOT LIMITED <br />TO, THE ADDITION OF WHATEVER TEMPORARY BRACING OR TIE <br />DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE <br />REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR <br />AFTER COMPLETION OF THE PROJECT, <br />WALL SECTIONSA <br />WALL SECTIONS <br />11C WALL SECTIONS <br />Ala INTERIOR ELEVATIONS <br />BUILDING AREA <br />9,000 SF <br />1)00 SFBE <br />BUILDING HEIGHT <br />40' <br />16'-8" <br />GYPSUM WALLBOARD <br />RIGID INSULATION <br />6.2. EVERY UNOCCUPIED ATTIC SPACE SHALL BE SUS DIVIDED BY <br />DRAFT5TOP5 INTO AREAS NOT TO EXCEED 3,000 SQFT <br />6.3.ANY CONCEALED SPACE BETWEEN THE CEILING AND THE <br />FLOOR OR ABOVE ROOF SHALL BE DRAFT5TOPPED FOR THE <br />6. ALL PRODUCTS AND PARTS SHALL FIT TOGETHER NEATLY, WITHOUT <br />DAMAGE OR DISFIGUREMENT. EXCEPT FOR SPECIFIED CURVED <br />5URFACE5, ALL PRODUCTS AND PARTS SHALL BE CONSTRUCTED/ <br />Alb INTERIOR ELEVATIONS <br />A8a CABINET DETAILS <br />Aft CABINET DETAILS <br />NUMBER OF STORIES <br />2 <br />I <br />TYPES OF CONSTRUCTION <br />BATT INSULATION <br />FULL DEPTH OF THE SPACE ALONG THE LINE OF SUPPORT FOR <br />THE FLOOR OR ROOF STRUCTURAL MEMBERS AND, IF <br />NECESSARY, AT OTHER LOCATIONS TO FORM AREAS NOT TO <br />EXCEED 1;000 SQFT FOR ANY SPACE BETWEEN CEILING AND <br />FABRICATED AND INSTALLED TRUE, IN LINE, AND PLUMB. ALL NON <br />CONFORMING u)oRK SHALL BE REJECTED AND RE -ACCOMPLISHED <br />BY THE GENERAL CONTRACTOR AT NO ADDITIONAL COSTS TO THE <br />OWNER. <br />Aga DOOR SCHEDULE / DOOR DETAILS <br />A9b WINDOW SCHEDULE / WINDOUJ DETAILS <br />AIO MISCELLANEOUS DETAILS <br />TYPE OF CONSTRUCTION - ve uNSPRINKLERED <br />TABLE 601 - FIRE RESISTANCE RATINGs FOR BUILDING ELEMENTS <br />FLOOR, AND 3,000 SOFT FOR ANY SPACE BETWEEN CEILING <br />AND ROOF <br />6.4.0RAFT6TOPPING MATERIALS SHALL BE NOT LESS THAN 1/2" <br />THICK GYPSUM BOARD, 15/32" PLYWOOD, OR OTHER <br />APPROVED MATERIALS THAT ARE ADEQUATELY SUPPORTED <br />6.5.THE INTEGRITY OF ALL DRAFT5TOP5 SHALL BE MAINTAINED <br />1, ALL WORK SHOWN ON THE DRAWINGS SHALL BE CONSTRUCTED OF <br />NEW COMPONENTS. <br />6. ALL BIDS SHALL BE PREPARED FROM A COMPLETE SET OF <br />CONSTRUCTION DOCUMENTS. COMPLETE SETS OF DOCUMENTS SHALL <br />&pi FINISH FLOOR PLAN / FINISH SCHEDULE <br />NI ARCHITECTURAL SPECIFICATIONS <br />N2 ARCHITECTURAL SPECIFICATIONS <br />BUILDING ELEMENT <br />REQUIRED <br />PROVIDED <br />PRIMARY STRUCTURAL FRAME <br />0 HR <br />0 HR <br />BEARING WALLS - EXTERIOR <br />0 HR <br />0 HR <br />BEARING WALLS - INTERIOR <br />0 HR <br />0 HR <br />NOT BE BROKEN UP FOR BID PURPOSES. SUCH ACTION MAY RESULT <br />1. WALL AND ROOF/ CEILING ASSEMBLIES NOTED AS U.L., G.A. OR OTHER <br />APPROVED TESTING AGENCIES ARE CONSIDERED PROPRIETARY. <br />PROPRIETARY ASSEMBLIES MUST BE BUILT UTILIZING THE <br />COMPONENTS, MEANS, AND METHODS SPECIFIED BY THE TESTING <br />IN A LACK OF INFORMATION IN REFERENCE TO THE SCOPE OF WORK <br />TO BE PERFORMED. <br />9. IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO <br />I la FOUNDATION PLAN <br />1 lb FOUNDATION DETAILS <br />1 2a FRAMING PLAN <br />NONBEARING WALLS AND PARTITION5 - EXTERIOR <br />0 HR <br />0 HR <br />- <br />NONBEARING WALLS AND PARTITIONS INTERIOR <br />0 HR <br />0 HR <br />FLOOR CONSTRUCTION AND SECONDARY MEMBERS <br />0 HR <br />0 HR <br />SYMBOL LEGENDAGENCY. <br />8. PROVIDE AND INSTALL PORTABLE FIRE EXTINGUISHERS AS SHOWN IN <br />THESE DOCUMENTS OR AS OTHERWISE DIRECTED BY THE LOCAL <br />FIRE MARSHAL. <br />5. INTERIOR WALL AND CEILING FINISHES SHALL BE CLASSIFIED IN <br />ACCORDANCE WITH ASTM E 84. <br />10. SUSPENDED ACOUSTICAL CEILING SYSTEMS SHALL BE INSTALLED IN <br />AC CORDANCE WITH THE PROVISIONS OF ASTM C 635 AND ASTM C <br />PERSONALLY FIELD INSPECT THE PROJECT SITE PRIOR TO THE <br />PREPARATION AND SUBMITTAL OF HIS BID. THIS INSPECTION IS <br />REQUIRED SO THAT THE CONTRACTOR SHALL BE TOTALLY FAMILIAR <br />WITH THE EXISTING CONDITIONS AND THEIR INTERFACE WITH THE NEW <br />CONSTRUCTION AS DEFINED IN THESE CONSTRUCTION DOCUMENTS. <br />10, UNLESS OTHERWISE SPECIFIED, THE G.G. SHALL FURNISH A WRITTEN <br />GUARANTEE FOR ALL WORK (EQUIPMENT, MATERIALS, AND LABOR), <br />AGAINST ANY DEFECTS IN SAID WORK FOR A PERIOD OF ONE (1) <br />YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION, WITH ALL <br />APPROPRIATE OREPAIRS OR REPLACEMENTS AT NO ADDITIONAL <br />COST TO <br />I 2b FRAMING DETAILS <br />1 2G FI?AMINKs DETAILS <br />63 STRUCTURAL SPECIFICATIONS <br />PO PLUMBING COVER SHEET <br />PI PLUMBING FLOOR PLAN - DEMOLITION <br />PLUMBING FLOOR PLAN - GRAVITY PIPING <br />1 PLUMBING FLOOR PLAN - PRESSURE PIPING <br />P4 PLUMBING FLOOR ROOF -GRAVITY PIPING <br />1 PLUMBING SANITARY RISER DIAGRAM <br />ROOF CONSTRUCTION AND SECONDARY MEMBERS <br />0 HR <br />0 HR <br />_ <br />BUILDING SECTION SYMBOL <br />TABLE 602 - FIRE RESISTANCE RATINGS FOR EXTERIOR WALLS BEARING AND NON BEARING <br />BASED ON FIRE SEPARATION DISTANCE <br />FIRE SEPARATION DISTANCES <br />REQUIRED <br />PROVIDED <br />LESS THAN 5'-0" <br />1 HR <br />N/A <br />FROM F-0" TO 10'-0' <br />1 HR <br />N/A <br />FROM 10'-0" TO 20'-0" <br />0 HR <br />N/A <br />- <br />11. MATERIAL, OTHER THAN FOAM PLASTIC USED AS INTERIOR TRIM <br />SHALL HAVE A MINIMUM CLASS C FLAME SPREAD AND <br />11. IT SHALL BE THE RESPONSIBILITY OF THE G.C. AND/OR <br />CONTRACTORS TO COMPLY WITH ALL THE REQUIREMENTS OF THE <br />1 6 PLUMBING WATER RISER DIAGRAM <br />FROM 20'-0" TO 30'-0" <br />0 HR <br />N/A <br />GREATER THAN 30'-0" <br />0 HR <br />0 HR <br />WALL SECTION SYMBOL <br />SMOKE -DEVELOPED INDEX WHEN TESTED IN ACCORDANCE WITH <br />ASTM E 84. <br />OCCUPATIONAL SAFETY AND HEALTH ACT OF 1910 BY THE U.S" <br />DEPARTMENT OF LABOR, AND REQUIRE ALL ITS SUBCONTRACTORS <br />AND EMPLOYEES TO COMPLY WITH THIS LAW, AND ANY RELATED <br />QI �'10.I MECHANICAL LEC�END� NOtEQJ� AND SCHEDULEQJ <br />M0.2 MECHANICAL SPECIFICATIONS <br />12. INTERIOR WALL SUWACES WITHIN (2) TWO FEET OF URINALS AND <br />STATE OR LOCAL LAWS. <br />MO.3 MECHANICAL SPECIFICATION <br />_ <br />DETAIL SYMBOL <br />WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONA55ORBENT <br />SUWACE TO A HEIGHT OF (4) FOUR FEET ABOVE THE FINISHED <br />FLOOR MINIMUM. THE MATERIALS USED IN SUCH WALLS SHALL BE OF <br />A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. <br />13. SIGNAGE SHALL BE PROVIDED AS REQUIRED AND AS STATED IN THE <br />2012 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION <br />AND SHALL COMPLY WITH CHAPTER 1 SECTION 103 SIGNS. <br />12. THE DATA GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS <br />COULD BE SECURED. THEIR ABSOLUTE ACCURACY IS NOT <br />GUARANTEED, AND THE G.G. SHALL OBTAIN EXACT LOCATIONS, <br />MEASUREMENTS, LEVELS, ETC. AT THE SITE AND SHALL <br />SATISFACTORILY ADAPT HIS WORK TO THE ACTUAL CONDITIONS OF <br />THE BUILDING. DO NOT SCALE PRINTS. VERIFY ALL DIMENSIONS <br />WITH THE ARCHITECT PRIOR TO COMMENCING WORK. <br />FIRE AND SMOKE PROTECTION FEATURES <br />MO.4 MECHANICAL SPECIFICATIONS <br />MI.I MECHANICAL FLOOR PLAN - DEMOLITION <br />��M�,�12 MECHANICAL ROOF PLAN - DEMOLITION <br />/ � /�,�Y .l MECHANICAL FLOOR PLAN - NEW CCNSTRI,ICTI <br />M2.2 MECHANICAL ROOF PLAN - NEW CONSTRUCTION <br />M3.I MECHANICAL DETAILS <br />ASSEMBLY FIRE RATINGS <br />REQUIRED <br />PROVIDED <br />FIRE WALL - 106.1 AND TABLE 106.4 <br />N/A <br />N/A <br />SHAFT AND EXIT ENCLOSURES - 108.4 / 101ed <br />LESS THAN 4 STORIES <br />N/A <br />N/A <br />OCCUPANCY SEPARATION - 1013.8 / 508 <br />N/A <br />N/A <br />_ <br />-- DETAIL SYMBOL <br />/ <br />13. THESE DOCUMENTS AND THE INFORMATION CONTAINED HEREIN SHALL <br />NOT BE ALTERED IN ANYWAY BY THE CONTRACTOR OR THE OWNER. <br />ALTERATIONS SHALL BE MADE ONLY BY THE ARCHITECT OF <br />RECORD. <br />ASE0 LEGEND AND L*wiws FIXTURE SCHEDULE <br />E) SITE PLAN - LIGHTING AND POWER <br />E2 FLOOR PLAN - DEMOLITION - POWER AND <br />LIGHTING <br />TENANT SEPARATION - 1013.1 <br />N/A <br />N/A <br />EXIT PASSAGEWAY - 101.3.3 / 1022.1 <br />N/A <br />N/A <br />HORIZONTAL EXIT - 1013A / 1023.1 <br />N/A <br />N/A <br />3ROOF PLAN - DEMOLITION - POWER <br />4 FLOOR PLAN - LIGHTINGA <br />$ FLOOR PLAN - POWER AND COM"ICATION <br />1(p <br />SINGLE OCCUPANCY FIRE AREA - 1013.9 <br />W <br />N/A <br />CORRIDORS (OCCUPANT LOAD LESS THAN 30) -TOP <br />1018.1 (UNSPRINKLERED) <br />N/A <br />N/AR <br />0'-0" F.F.E. ELEVATION MARK <br />OF SLAB <br />- <br />El ELECTRICAL DETAILS <br />ib POWER DISTRIBUTION RISER DIAdR4M AND <br />PANEL EDULE <br />INTERIOR ELEVATION MARK <br />INTERIOR FINISHES <br />ES SPECIFICATIONS <br />EIm SPECIFICATIONS <br />INTERIOR WALL AND CEILING FINISH REQUIREhMTS BY OCCUPANCY -TABLE 803.9 <br />KEYED DRAWING NOTES <br />Ell SPECIFICATIONS <br />GROUP: BUSINESS GROUP'5' <br />O <br />DOOR NUMBER SYMBOL <br />EXIT ENCL05URE5 AND EXIT PASSAGEWAYS <br />CLA55 A <br />jis n �S j <br />t✓ <br />� (,1.1'h <br />tt��ff <br />CORRIDORS <br />CLASS B <br />ROOMS AND ENCLOSED SPACES <br />CLASS C <br />000 ROOM NUMBER SYMBOL <br />/ 's <br />O WINDOW SYMBOL <br />MEANS OF EGRESS <br />/ ,01- <br />TABLE 1004.0 - MAXMUM FLOOR AREA ALLOWANCE PER OCCUPANTOOR <br />AREA <br />ESQ <br />I <br />FUNCTION OF SPACE <br />FT. PERM <br />OCCUPANTS <br />CCCUPANT <br />REVISION <br />PROJECT SCOPE <br />BUSINESS - GROUP'B' <br />100 SF <br />12 OCCUPANTS <br />FLORIDA PRAPPROVALODUCT <br />MEANS OF ECsRESS REQUIRED PROVIDED <br />SYSTEM <br />MANUFACTURER <br />PRODUCT <br />APPROVAL NUMBER <br />RENOVATIONS AND ADDITIONS TO AN EXISTING SINGLE STORY FREE <br />STANDING MASONRY BUILDING INCLUDING BUILDING, FULL SITE <br />DEVELOPMENT AND UTILITIES. <br />EGRE58 WIDTH PER PERSON (LEVEL) - 1005.1 <br />02" x 12 : 14.4" <br />2001. <br />DOORS <br />YKK AP <br />35DH MEDIUM STYLE <br />S112,1 <br />MINIMUM CLEAR EXIT DOOR OPENING - 1008.1.1 <br />32" <br />> 34 <br />WINDOWS <br />YKK AP <br />YES 45 FI <br />1019.1 <br />MAXIMUM COMMON PATH OF TRAVEL - 10143 <br />15 FT <br />< 15 <br />WALL TYPES <br />ROOFING <br />DURO-LAST <br />THERMOPLASTIC <br />SINGLE PLY <br />1559.1 <br />MAXIMUM TRAVEL DISTANCE - TABLE 1016.1 <br />200 FT <br />< 200 <br />MINIMUM CORRIDOR WIDTH - 10182 <br />44" <br />> 44 <br />MAXIMUM DEAD END CORRIDOR LENGTH - 1018.4 <br />20 FT <br />< 20 <br />_ <br />KEY PLAN SECTION SYMBOL <br />MINIMUM NUMBER OF EXITS - 102IJ / 10211 <br />2 <br />4 <br />LOCATION MAP <br />. j <br />��j � f>.: -• .. 1I` ' ,. 1 <br />1 _ <br />1 <br />i r` <br />; <br />��T����i'o-�; L <br />- -- � <br />n <br />m ��,ry,uie nve; � - 6alaen ovM�}f .�� :!}LcdWA,itsFinena l0 -- � v <br />0 9 <br />rOMty LA <br />.axirein <br />cw.coara I � m,Ef."aN1. <br />0o WA,, Cm�nwoW PI <br />Mtst�l89WN_ - <br />'. 11"tlWlLea nve <br />PROJECT <br />rdlwmp. � I� LOCATION <br />� � <br />m r rt <br />if.myol Nenvo, <br />;�1 mt-1 Me n-.IAr, 11 ? <br />• Fx}I A e 4_7 - n <br />¢ �Lq., 18I" Ava <br />a � f aSt1` �O <br />5 <br />PROJECT TEAM <br />ARCHITECT <br />OLIVERI ARCHITECTS <br />32101 U.S. HWY.1944- <br />PALM HARBOR, FLORIDA 34684 <br />121-181-1525 <br />STRUCTURAL <br />MOHAN ENGINEERING <br />3040 GULF TO BAY BLVD., SUITE 209 <br />CLEARWATER, FLORIDA 33159 <br />121. 191" 1505 <br />PLUMBIN[s / MECHANICAL <br />/ ELECTRICAL <br />APG ELECTRIC <br />4825 140TH AVENUE NORTH, SUITE K. <br />CLEARWATER, FLORIDA 33162-3822 <br />121-530-0011 <br />REVISIONS <br />BY <br />x � � <br />to <br />M CO <br />L J <br />�v U. <br />o 0 E <br />cli <br />a <br />� v <br />U N .4 <br />> <br />t E - <br />d _rn o <br />20- <br />O N . <br />ti <br />Cu c <br />ti o <br />CV <br />Cl) <br />tr <br />�4 <br />u <br />O ._ <br />O <br />U C' <br />-z <br />zo <br />U � � <br />O m .F J <br />o <br />-J L - -- <br />C <br />0 ��'0 <br />=U <br />t <br />a>,0 <br />0 W <br />CC �O N ao <br />Q C) <br />J <br />Q to <br />�U <br />00 <br />�W5 <br />i <br />Date: 12. 23. 14 <br />Scale: AS NOTED <br />Project Mgr: DSH <br />Drawn: SEH <br />Job: 14-137 <br />Sheet <br />T2 <br />1, , <br />1, . <br />