My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6748 Gall Blvd (4)
Zephyrhills
>
Building Department
>
Building Plans
>
6748 Gall Blvd (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:37:39 PM
Creation date
2/25/2025 9:46:54 AM
Metadata
Fields
Template:
Building Plans
Street #
6748
Location
Gall Blvd
Contractor
Stevens Const
Building Plans - Permit #
9118
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACCEPTANCE TEST NOTES <br />ACCEPTANCE TEST: <br />THE FIRE PROTECTION SYSTEM SHALL BE TESTED PER FLORIDA BUILDING CODE <br />( CHAPTER 9 FIRE PROTECTION SYSTEM ) AND FLORIDA FIRE PREVENTION CODE. <br />THE TESTS SHALL BE CONDUCTED IN THE PRESENCE OF THE BUILDING CODE <br />OFFICIAL. <br />CONTRACTOR SHALL NOTIFY THE AUTHORITY HAVING JURISDICTION AND OWNER'S <br />REPRESENTATIVE OF THE TIME AND DATE TESTING WILL BE PERFORMED. <br />ACCEPTANCE TEST RECOREDS SHALL BE RETAINED FOR THE LIFE OF THE SYSTEM <br />( SUBSEQUENT TESTS SHALL BE COMPARED WITH THE ACCEPTANCE TEST). <br />ACCEPTANCE TEST SHALL BE IN ACCORDANCE WITH NFPA 13, STANDARD FOR THE <br />INSTALLATION OF SPRINKLERS SYSTEM. <br />HYDROSTATIC TESTS: <br />THE NEW FIRE PROTECTION SYSTEM ( PIPING AND ATTACHED APPURTENANCES ) <br />SUBJECTED TO SYSTEM WORKING PRESSURE SHALL BE ISOLATED AND <br />HYDROSTATICALLY TESTED AT 200 PSI AND SHALL MAINTAIN THAT PRESSURE <br />WITHOUT LOSS FOR 2 HOURS. <br />LOSS SHALL BE DETERMINED BY A DROP IN GUAGE PRESSURE OR VISUAL LEAKAGE. <br />THE TEST PRESSURE SHALL BE READ FROM A GUAGE LOCATED AT THE LOW <br />ELEVATION POINT OF THE SYSTEM BEING TESTED. <br />SYSTEM OPERATIONAL TESTS: <br />WATERFLOW DETECTING DEVICES INCLUDING THE ASSOCIATED ALARM CURCUITS <br />SHALL BE FLOW TESTED THROUGH THE INSPECTOR'S TEST CONNECTION AND <br />SHALL RESULT IN AN AUDIBLE ALARM ON THE PREMISES WITHIN 5 MINUTES <br />AFTER SUCH FLOW BEGINS AND UNTIL SUCH FLOW STOPS. <br />THE MAIN DRAIN VALVE SHALL BE OPENED AND REMAIN OPEN UNTIL THE SYSTEM <br />PRESSURE STABILIZES. <br />CONTRACTOR SHALL RECORD THE STATIC AND RESIDUAL PRESSURES ON THE <br />TEST CERTIFICATE <br />OPERATING TEST: <br />CONTROL VALVE SHALL BE FULLY CLOSED AND OPENED UNDER SYSTEM WATER <br />PRESSURE TO ENSURE PROPER OPERATION. <br />FIRE PROTECTION ABBREVIATIONS <br />A.F. F. <br />ABOVE FINISHED FLOOR <br />F. E.C. <br />FIRE EXTINGUISHER CABINET <br />A.F.G. <br />ABOVE FINISHED GRADE <br />O.S. &Y. <br />OUTSIDE STEM AND YOKE <br />A.P. <br />ACCESS PANEL <br />F SR <br />FIRE STANDPIPE <br />A/S <br />AUTOMATIC SPRINKLER <br />F.D.V. <br />FIRE DEPARTMENT VALVE <br />B.F.F. <br />BELOW FINISHED FLOOR <br />F.D C. <br />FIRE DEPARTMENT CONNECTION <br />C.V. <br />CHECK VALVE <br />FIRE PROTECTION LEGEND <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />F <br />FIRE LINE OR MAIN <br />CAP AT END OF PIPE <br />A/S <br />AUTOMATIC SPRINKLER PIPING <br />CONCEALED SPRINKLER HEAD <br />D <br />DRAIN PIPING <br />0 <br />SEMI -RECESSED SPRINKLER HEAD <br />PIPE TURNED UP <br />0— <br />UPRIGHT SPRINKLER HEAD <br />PIPE TURNED DOWN <br />► <br />SIDEWALL SPRINKLER HEAD <br />CHECK VALVE <br />FLOW SWITCH <br />—I+F— <br />UNION IN PIPE <br />O.S.&Y. GATE VALVE W/ TAMPER SWITCH <br />FP-1, ETC. <br />COMPONENT IDENTIFICATION <br />CONNECT TO EXISTING <br />Q <br />HYDRAULIC CALCULATION NODE POINT <br />—NM- <br />DIRECTION OF FLOW ARROW <br />SPRINKLER HEAD LEGEND <br />TYPE <br />K-FACT <br />TEMP <br />LOCATION <br />1. RECESSED CROME PENDANT - QRS <br />5.6 <br />1550 <br />ALL SPACES UNLESS OTHERWISE NOTED <br />2. CONCEALED - QRS (W/WHITE C.P.) <br />5.6 <br />1550 <br />AS SHOWN ON FLOOR PLAN <br />3. UPRIGHT GENERAL - QRS <br />5.6 <br />1550 <br />ELECTRIC ROOMS AND ROOMS W/NO CEILINGS <br />* SEE SPECIFICATIONS FOR MODEL NUMBERS. <br />GENERAL SPRINKLER NOTES <br />1. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES. MAKE ALL PIPING OFFSETS <br />REQUIRED AS PER JOB CONDITIONS. <br />2. CONTRACTOR TO PROVIDE AND TURN OVER TO THE OWNER AT LEAST (6) SPARE SPRINKLERS <br />OF SAME TYPE AND TEMPERATURE RATING BEING INSTALLED. <br />3. PROVIDE SPRINKLER GUARDS ON HEADS IN ELECTRICAL ROOMS AND MECHANICAL ROOMS. <br />4. ALL SPRINKLER HEADS SHALL BE CENTERED IN CEILING TILE AND PRESENT A NEAT AND <br />BALANCED CEILING PATTERN UNLESS SHOWN OTHERWISE. COORDINATE SPRINKLER HEAD <br />LOCATIONS WITH ARCH. REFLECTED CEILING PLAN AND ALL OTHER CEILING DEVICES. <br />5. PROVIDE AND MAINTAIN A MINIMUM CLEARANCE OF 18" BETWEEN THE BOTTOM OF THE <br />SPRINKLER DEFLECTOR AND THE TOP OF STORAGE, FILE, SHELVING, ETC. <br />6. ALL SPACES SHALL BE PROTECTED WITH QUICK RESPONSE SPRINKLER HEADS. <br />7. THE CONTRACTOR SHALL KEEP A SET OF MARKED UP DRAWINGS AS THE JOB PROGRESSES. <br />NO MAJOR CHANGE SHALL BE MADE TO FIRE PROTECTION DESIGN/ENGINEERING UNLESS <br />IT HAS BEEN COORDINATED, DRAWN AND SUBMITTED FOR APPROVAL TO THE ARCHITECT. <br />8. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS DESCRIBED IN NFPA 13 (2002) CHAPT.14 <br />TO OWNERS INS. CO. AND LOCAL AND STATE FIRE AUTHORITIES HAVING JURISDICTION. <br />AFTER OBTAINING THESE APPROVALS SUBMIT THESE DRAWINGS TO ARCHITECT/ENGINEER <br />FOR THERE REVIEW. ALL OF THESE APPROVALS AND REVIEWS SHALL BE COMPLETED <br />BEFORE START OF PROJECT CONSTRUCTION. <br />9. CONTINUITY OF SERVICES: EXISTING BUILDING WILL REMAIN IN USE DURING CONSTRUCTION <br />OPERATIONS. WHEN AN INTERRUPTION OF AN EXISTING SERVICE IS NECESSARY, <br />CONTRACTOR SHALL COORDINATE WITH AUTHORIZED HOSPITAL PERSONNEL BEFORE MAKING <br />THE NECESSARY INTERRUPTION. <br />10. ALL EXISTING LOCATIONS ARE TAKEN FROM EXISTING DRAWINGS. IT WILL BE WITHIN THE <br />CONTRACTOR'S SCOPE OF WORK TO VERIFY EXISTING SERVICES AND THE EXACT LOCATION <br />OF PIPES, TO MAKE ALL OFFSETS; AND TO ADD NEW PIPING SYSTEMS TO THE EXISTING <br />PIPING SYSTEMS AS PART OF THE PROJECT CONTRACT. <br />11. ALL PENETRATIONS THROUGH WALLS AND FLOORS SHALL BE SLEEVED AND/OR PATCHED <br />AS DIRECTED BY THE SPECIFICATIONS. PATCHING SHALL MATCH EXISTING FINISH. <br />(SEE ARCH. DRAWINGS). <br />12. THIS PROJECT INVOLVES THE ADDITION OF 10 OR LESS AUTOMATIC SPRINKLER HEADS. <br />ACCORDINGLY, SUBMISSION OF COMPLETE AUTOMATIC SPRINKLER SYSTEM CONSTRUCTION <br />DOCUMENTS BY THE ENGINEER OF RECORD ARE NOT REQUIRED. <br />13. CONTRACTOR SHALL COORDINATE SPRINKLER SYSTEM OUTAGES WITH OWNER SO THAT A <br />FIRE WATCH IS MAINTAINED DURING THOSE OUTAGES. AT OWNERS OPTION THE CONTRACTOR <br />SHALL RE -ACTIVATE THE SPRINKLER SYSTEM DURING NON -CONSTRUCTION HOURS IN <br />ORDER TO MAINTAIN FULL SPRINKLER COVERAGE IN AREA OF RENOVATION. <br />FIRE PROTECTION DEMOLITION NOTES <br />1) CONTRACTOR SHALL REMOVE INACTIVE EXISTING SERVICES <br />TO FIRE SPRINKLERS AND EQUIPMENT THAT HAS BEEN OR WILL BE <br />REMOVED TO ALLOW FOR THIS NEW CONSTRUCTION. <br />CONTRACTOR SHALL CAP ACTIVE SERVICES NEXT TO MAINS <br />ABOVE CEILING, IN WALLS OR BELOW FLOORS, SO AS NOT TO <br />INTERFERE WITH NEW ARRANGEMENT OF RENOVATED AREA. <br />2) WHERE EXISTING FIRE PROTECTION EQUIPMENT, AUTOMATIC <br />SPRINKLER HEADS AND RELATED ITEMS ARE TO BE REMOVED <br />CONTRACTOR SHALL SUBMIT COMPLETE LIST TO THE OWNER. <br />ALL ITEMS THAT THE OWNER WISHES TO RETAIN SHALL BE <br />DELIVERED TO BUILDING STORAGE WHERE DIRECTED BY OWNER. <br />ITEMS THAT OWNER DOES NOT WISH TO RETAIN SHALL BE DISPOSED <br />OF LEGALLY. <br />3) CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING AND PATCHING <br />REQUIRED BY HIS WORK. RESTORE FINISHES TO MATCH EXISTING <br />SURFACES IN COLOR, TEXTURE AND APPEARANCE. <br />FIRE PROTECTION INDEX <br />SHEET <br />NO. <br />SHEET TITLE <br />F0.1 <br />FIRE PROTECTION SCHEDULES, NOTES, LEGENDS AND SHEET INDEX <br />F3,1 <br />FIRST FLOOR FIRE PROTECTION PLAN - NEW CONSTRUCTION <br />F4.1 <br />FIRE PROTECTION DETAILS <br />Project No. 09002.00 <br />FOO <br />1 <br />© 2009 BH(PK Architects, Inc. <br />$DATE$ $TIME$ $FILEA$ <br />