<br />DIVISION I - GENERAL
<br />SECTION 01045 - GUTTING AND PATCHING
<br />Scope: I. Cutting and patching includes cutting into existing construction For the installation
<br />or performance of other work and patching required to restore the surfaces to their
<br />original condition,
<br />a. Unless otherwise specified the requirements for this section also apply to
<br />mechanical and electrical work.
<br />b. Do not cut and patch exposed work in a manner that in the architect/Engineers
<br />opinion results in lessening the buildings aesthetic qualities. Replace any work
<br />judged by the Architect/Engineer to be usually satisfactory.
<br />SECTION 01500 - SUBMITTALS, PRODUCTS, AND SUBSTITUTIONS
<br />Scope: I. Format for submittals: as required for specific type and by individual sections.
<br />2. Types of submittals and number of copies.
<br />o.5hop drawings, reviewed and annotated by the general contractor 6 copies
<br />b. Product data - 6 copies
<br />c. Samples - 2, plus extra samples as required to indicate range of color, Finish, and
<br />texture to be expected.
<br />d. Mock-ups - as required in individual sections.
<br />e. Inspection and test reports - 4 copies
<br />F. Warranties - 2 copies
<br />g. Survey data - 2 copies.
<br />In. Closeout submittals - 2 copies
<br />DIVISION 6 - WOOD AND PLASTICS
<br />SECTION 06100 - ROUGH CARPENTRY
<br />Scope: I. Provide rough carpentry work
<br />a. Noilers, blocking, Furring and sleepers
<br />Products:l. Lumber, finished 4 sides, Icl% maximum moisture content.
<br />a. Light framing: Construction grade Douglas fir or southern pine, appearance
<br />grade where exposed.
<br />b. Structural Framing and timbers: No. I grade Douglas fir or southern pine,
<br />appearance grade where exposed.
<br />c. Boards: Construction grade
<br />2. Wood for nailers, Furring and sleepers: Construction grade, finished 4 sides,
<br />IcI% moisture content. Pressure preservative treat items in contact with
<br />roofing, flashing, waterproofing, masonry, concrete or the ground.
<br />3. Plywood, APA rated for use and exposure.
<br />a. Backing: Interior A/C grade.
<br />4. Building paper: Asphalt saturated felt, non -perforated, ASTM D 226, Typ I. 30 Ibs
<br />5. Wood treatment:
<br />a. Exterior wood AWPA standard UI and TI. Cotogories UCI, UO2, UO3A,
<br />U0313, CU4A, CU4B Alkaline Copper Quaternary based treatment.
<br />b. Interior wood AWPA CI Timber, AWPA Cq Plywood, AWPA 031 Lumber not
<br />in contact with ground and protected From water, AWPA 5 Waterborne
<br />Preservatives, AWPA M4 Disodium Octoborote based treatment.
<br />6. Sealants: For settings wood bucks and nailers in exterior openings.
<br />1. Fire Retardant Treated Wood: All wood blocking within the insulated building
<br />envelope shall be Fire retardant treated to comply with AWPA C20 (lumber} and
<br />AWPA C21 (plywood) for treatment type.
<br />a. Provide UL label on each treated. Redry treated lumber.
<br />SECTION 06200 FIN15H CARPENTRY
<br />Description of Work:
<br />Wood trim, chair rail, crown molding and door casings as indicated on drawings
<br />Quality Assurance
<br />A. Factory -mark each piece of lumber and plywood with type, grade, mill and grading
<br />agency identification.
<br />B. Comply with applicable standards of AWI Architectural Woodwork Institute
<br />secion 0300
<br />I. Grade Premium
<br />Materials
<br />A. Nominal sizes are indicated except as shown by detail dimensions.
<br />Provide dressed or worked and dressed lumber, as applicable,
<br />manufactured to actual sizes and patterns as shown.
<br />B. Popular painted finish. Use pieces which are made of solid lumber stock.
<br />C. Fasteners and Anchorages. Provide nails screws adn other anchoring
<br />devices of the type size material and Finish required. For application
<br />indicated to providesecure attachment concealed where possible.
<br />Adjustment, Cleaning, Finishing and Protection
<br />A. Repair damaged and defective finish carpentry work Kherever possible to eliminate
<br />defects Functionally and visually; where not possible to repair properly, replace
<br />woodwork. Adjust joinery for uniform appearance
<br />SECTION 06400 - ARCHITECTURAL WOODWORK
<br />Scope: I. Provide shop fabricated woodwork and casework.
<br />Products:l. Quality standard For fabrication and products: Architectural Woodwork Institute
<br />Quality Standards, Custom grade Flush overlay unless otherwise noted.
<br />2. Wood species
<br />a. Provide sealed plywood at sinks and wet areas.
<br />3. Plastic laminate: all exposed and semi -exposed surfaces
<br />AWI 5wction 400 premium grade
<br />a. Horizontal surfaces: GP-50 (0.050" nominal thickness)
<br />b. Vertical surfaces: GP-28 (0.28" nominal thickness)
<br />SECTION 06400 - ARCHITECTURAL WOODWORK (cont)
<br />4.5olid Surface- Provide solid surface counter tops extent as
<br />shown on the drawings
<br />5. Hardware:
<br />Doors:
<br />I pr hinges - Blum Clip 110 degree self closing
<br />I pull Stanley 348515 5" Satin Chrome
<br />Drawers:
<br />I pull- Stanley 346515 5" Satin Chrome
<br />I pr drawer slides Knape and Bogt No 1320 self closing
<br />DIV15ION 1 - INSULATION
<br />SECTION 01200 - INSULATION
<br />Description of Work:
<br />A. Extent of insulaiton work is shown on drawings and indicated by
<br />provision of this seciton.
<br />B. Appplications of insulaiton specified in this secion include the Following
<br />1. Unfoced Fiberglass sound attenuation butts
<br />2. Fire 5afing Insulation
<br />Quality Assurance
<br />A. Fire Performance Choracteristices
<br />I. Surface Burning Characteristics A5TM E 84
<br />2. Fire Resistance Rating A5TM E Ilq
<br />Acceptable Manufacturers
<br />A. Manufacturers subject to compliance with requirements provide
<br />products of one of hle following
<br />I. Manufacturer of Fire 5aFing
<br />IIG Minwool Corp.
<br />Johns- Manville Corp.
<br />United States Gypsum Co.
<br />2. Manufacturer of Glass Fiber Insulaiton
<br />CertainTeen Corp.
<br />Knouf Fiber Glass Gmb H
<br />Manvill Corp
<br />Owens-Corning Fiberglas Corp.
<br />Insulating Materials
<br />A. General: Provide insulating materials which comply with
<br />requirements indicated for materials compliance with reference
<br />standards and other characteristics.
<br />I. Preformed units sizes to fit application indicated, selected from
<br />manufacturer's standard thickness, widths and lengths.
<br />2. Sound attenuation butts. Provide unFoced mineral Fiber butt
<br />insulation produced by combining9 gglass fibers with thermosetting
<br />resins to comply with A5TM C 6b5 for Type I (blankets/butts without
<br />membrane facing). Coordinate installation of sound attenuation
<br />butts with installation of gypsum board.
<br />3. Where sound -rated drywall construction is indicated seal construction
<br />at perimeters, control and expansion joints, openings and penetrations
<br />with a continuous bead of acoustical sealant including a bead at both
<br />faces of partitions. Comply with ASTM C qlq and manufacturer's
<br />recommendations for location of edge trim and close off sound -Flanking
<br />paths around or through construction
<br />B. Fire 5afing Provide fire sofing for installation in locations as indicated
<br />or required.
<br />I. Manufacturer shall provide certification that insulation complies with
<br />OF plicable buildingg code requirements for performance of insulation
<br />within fire protecEion assembly indicated on drawings IIG Minwool or eq.
<br />DIVISION 8 - DOORS AND WINOOW5
<br />SECTION 08110 - WOOD DOOR d FRAME5
<br />Scope: I. Provide wood Frames
<br />2. Provide solid core wood doors.
<br />Products: I. Frames: Wood Frames to match existing:
<br />2. Doors: 13/4" thick, Flush
<br />Doors: 13/4" thick, 6 panel - Alternate #1
<br />a. Interior doors: Solid core Poplar
<br />3. Finish
<br />a. Painted
<br />4. Fire Rating: UL Labeled where required.
<br />Alternate #1 - Provide 6 panel wood door. Solis core wood
<br />SECTION 06110 - FIN15H HARDWARE
<br />Scope: I. Provide Finish hardware for sliding, swinging and bi-fold doors.
<br />Products: I. ADA compatible hardware, Finish and type to match existing.
<br />2. Hinges, butts and pivots: Full -mortise, 5knuckles
<br />ball -bearing type: Stanley
<br />3. Locksets and lotchsets:
<br />a. Standard duty (light commercial): 5chloge
<br />A Series. Lever style
<br />4. Bolts adn coordinators: Ives
<br />5. Exit devices: Von Duprin
<br />6. Closers
<br />a. Low Frequency doors: LCN 4050/4150 series.
<br />b. High frenquency door (fire -labeled doors, toilet room doors,
<br />stair doors) LON 4010/4110 series.
<br />1. Door Trim: Kickplates, omor plate, plastic plates; Bobrick.
<br />8. Stops: Ives
<br />q. Thresholds:Pemco
<br />10. Finish: Brushed Stainless
<br />SECTION 05800 - GLASS AND GLAZING
<br />Scope: I. Provide glass and glazing For all applications, including without
<br />limitation, sidelights, interior glazed partitions walls, windows
<br />and mirrors.
<br />2. Glass Schedule:
<br />a. Clear Float glass
<br />b. %4" clear tempered as required by code
<br />Products: I. Glazing Sheets
<br />a. Heat treated glass products, Fed. Spec 00-6-1403
<br />I. Tempered glass
<br />b. Mirrors, silvering copper coating, protective organic coating
<br />DIVISION q - FIN15HES
<br />SECTION Og250 - GYPSUM DRYWALL
<br />Scope: I. Gypsum drywall including screw type metal support systems.
<br />2. Drywall Finishing. Smooth joint tape and
<br />compound treatment for paint finish
<br />3. Moisture resistant gypsum board for installation in wet areas
<br />such as toilet rooms, mop rooms, janitors closets, food service
<br />areas, behind Fiberglass showers, and
<br />under the balance of wall the installations.
<br />Do not install in showers.
<br />4.Type C fire code gypsum drywall For rated assemblies
<br />Products: I. Gypsum wallboard: ASTM C 36, of types, edge configuration and thickness indicated:
<br />in maximum lengths available to minimize end -to -end butt joints
<br />a. Type: Regular, unless otherwise indicated. Type "X" for rated assemblies
<br />which has been tested adn listed by recognized authorities including ULFN
<br />and Gypsum Association
<br />b. Edges: Tapered
<br />c. Thickness: As indicated, or if not otherwise indicated, as required to comply
<br />with A5TM 6840 For application system and supporting spacing indicated.
<br />2. Wall/Partition Support Materials:
<br />a. Studs: A5TM 0645: 20 gage unless otherwise indicated. Use 16 gage steel studs
<br />at shower seat supports and rolling counter service doors or where required by equipment
<br />b. Use minimum 20 gage studs at high walls and door/borrowed light jambs.
<br />Consult manufacturers literature limiting height/gages of all wall assemblies
<br />3. Accessories: Galvanized steel corner beads, casing beads, control joints
<br />4. Acoustical sealant: US Gypsum Acoustical Sealant
<br />SECTION 041300- TILE
<br />Decription of work:
<br />A. Porcelain wall tile, Floor base and trim
<br />Quality Assurance:
<br />A. AN51 Standard for Ceramic Tile: Comply with AN51 A131.1 "American
<br />National Standard Specifications forCeromic Tile". Furnish the complying
<br />with Standard Grade requirements unless otherwise noted.
<br />B. Installation guidelines: Comply with the recommendatioins of the Tile Council of
<br />America 2006 edition For installation procedures.
<br />C. Propietory Materials: Handle, store, mix and apply proprietary
<br />setting and grouting materials in compliance with manufacturer's instructions.
<br />Samples:
<br />A. Submit samples of each product specified
<br />Extra Materials:
<br />A. Deliver extra materials to owner. Furnish 3% extra materols that match product installed as described
<br />below, package with protective covering for storage adn identiFed with lobles clearly describing contents.
<br />Tile Products:
<br />A. As specified on sheet A6.0 and A6.1
<br />Morter and Grout:
<br />A. Latex modified portlond cement dry -set morter; AN51 A118.4
<br />Grout:
<br />A. As Specified on Sheets Ab.0 and A6.1
<br />Tile Installation Standards:
<br />A: Comply with ANSI Standards, AN51 A108.5, ANSI A108.6,
<br />B. Manufacturer's requirements
<br />C. Tile Council of America Guidelines
<br />Tile installation:
<br />A. Extend tile into recess and under or behind equipment and fixtures
<br />B. Accurately Form intersections and returns. Carefully grid cut edges adn Fit the
<br />closely to electrical outlets, piping and fixtures
<br />C. Unless otherwise noted lay the in grid patter. Align joints when adjoining tiles on floor
<br />base and walls and trim. Adjust to minimize the cutting. Provide uniform joint widths u.o.n.
<br />SECTION 001510 - ACOUSTICAL CEILIN65
<br />Scope. I. Provide acoustical ceilings and metal suspension system.
<br />2. Fire Performance Characteristics: Provide materials that are identical to those tested for
<br />the following fire performance characteristics, per ASTM test method indicated below,
<br />by UL or other testing and inspecting organizations acceptable to authorities having
<br />jurisdiction. Identify acoustical ceiling components with appropriate markings of
<br />applicable testing and inspecting organizations.
<br />a. Flame spread 25 or less
<br />b. Smoke developed 450 or less
<br />3. Install products per manufacturers recommendations.
<br />Products: I. Acoustical panels. To be Armstrong Cirrus 2 x 2 with angled tegulor edge
<br />Exent as indicated on drawings
<br />2. Exposed grid suspension system: To match existing.
<br />3. Extra materials
<br />a. Provide additional panels and grid in on amount equal to 2.0 percent of each type
<br />of specified for maintenance stock.
<br />SECTION 001650 - RESILIENT FLOORING
<br />Scope: I. Provide resilient Flooring and base as indicated on drawings
<br />2. Install per manufacturers recommendations
<br />3. Fire Test Performance: Provide resilient Flooring which complies with the Following
<br />fire test performance criteria as determined by an independent testing laboratory
<br />acceptable to authorities having jurisdiction.
<br />a. Critical Radiant Flux (CRF): Not less than the Following rating per ASTM E 648.
<br />0.45 watts per so, cm.
<br />b. Flame Spread: Not more than 25 per A5TM E 54.
<br />c. Smoke Developed: Not more than 450 per A5TM E 84
<br />d. Smoke Density: Not more than 450 per ASTM Eb62
<br />e. Vinyl Plank extent as indicated on drawings
<br />Products: 2. Accessories
<br />a. Wall base: 4" vinyl cove as indicated on plans
<br />Alternate #2 Provide decorative scupltured vinyl base
<br />3. Adhesives (Cements): Waterproof, stabilized type as recommended by Flooring
<br />manufacturer to suit material and substrate conditions.
<br />4. Concrete slab primer. Non -staining type compatible with adhesive as recommended by
<br />Flooring manufacturer.
<br />5. Leveling compound: Latex type compatible with adhesive as recommended by
<br />Flooring manufacturer.
<br />6. Extra materials:
<br />a. Provide additional resilient flooring in the amount of 2.0 percent for each type
<br />specified For maintenance stock.
<br />Guarantees and Warrantees
<br />I. Upon completion the resilent Flooring contractor must submit a certificate
<br />guaranteeing the, installation to be freee of defects in workmanship for a
<br />period of I year to include the statement: that the resilent Flooring contractor
<br />shall at his own expense and upon written notice from the Architect promply
<br />correct/replace any and all improper work and material that may become
<br />apparent within 12 months after the date of Final completion.
<br />SECTION 001680 CARPETING
<br />Summary
<br />A. Extent location and details of each type of carpeting in indicated
<br />on the drawings and room finish schedule
<br />B. Work of this section includes furnishing and insulaiton of carpeting adhesives and
<br />accessories including:
<br />I. Broadloom carpet for glue -down installation with moisture barrier back
<br />Quality Assurance
<br />A. Carpet other than that specified on the drawings must be approved by
<br />the Architect 10 days prior to bid date.
<br />B. Provide fire test performance. Provide Class I carpeting which complies with
<br />the Following fire test perfiormonce criteriai as determined by an independent
<br />testing laboratory acceptable to authorities having jurisdiction.
<br />I. Critical Radiant Flux (CRF) not less than the following rating per ASTM 648
<br />0.45 watts per sq.cm.
<br />2. Flame Spread Not more than 25 per ASTM E 84
<br />3. Smoke Development Not more than 450 per A5TM E84
<br />4. Smoke Density Not more than 450 per A5TM E 662
<br />Site Visit
<br />A. Contractor must visit the site and be responsible for ail measurements
<br />and job conditions
<br />Guarantees and Warrantees
<br />I. Upon completion the carpeting contractor must submit a certificate
<br />guaranteeing the installation to be freee of defects in workmanship For a
<br />period of I year to include the statement: that the carpeting contractor
<br />shall at his own expense and upon written notice from the Architect promply
<br />correct/replace any and all improper work and material that may become
<br />apparent within 12 months after the date of Final completion.
<br />Maintenance Stock
<br />A. Supply loose stock equal to 10% of each potern and type specified
<br />Products
<br />A. As indicated on plans
<br />Installaiton
<br />A. Comply with manufacturer's recommendations For seam locations and directions
<br />of carpet monintoin uniformity of carpet directions and lay of pile at doors center seams
<br />and under doors. Do not place seams in traffic direction at doorway. All seams
<br />must be kept to a minimum and invisible as possible
<br />B. Existing or previously treated substrate with respect to wax, soap or other residual
<br />build-up must be removed prior to installation.
<br />SECTION 0414100 PAINTING
<br />Scope: I. Provide painting and surface preparation for all interior and exterior
<br />surfaces, as required
<br />2. Prepare surface and apply per manufacturers recommendation.
<br />Products: I. Premium products for all systems
<br />2. Interior Paint Schedule: New Surfaces:
<br />a. Zinc -coated Metal
<br />I. Semi -Gloss Alkyd Enamel: 2 finish coats over primer
<br />b. Primed Metal
<br />1. 5emi-Gloss Alkyd Enamel.. Two coats over existing primer
<br />c. Gypsum Board Level 5 finish
<br />I. Satin Latex Finishes: Two coats over primer
<br />d. Existing Zinc Coated or Primed Metal:
<br />1. Semi Gloss Alkyd Enamel: (2) coats over prepared surface.
<br />SECTION 10440- SPECIALTY SIGNS
<br />I. Provide specialty building signage
<br />2. Provide signage in compiance with ADA requirements
<br />SECTION 10522-FIRE EXTEING1,1I5HER5, CABINETS AND ACCESSORIES
<br />Scope: 1. Provide portable fire extinguisher cabinets. Provide mounting brackets where no cabinet is indicated
<br />Products: I. Fire Extinguishers: UL listed and labeled units J.L Industries
<br />a. Multi -purpose dry chemical type.
<br />2. Cabinets: Enamelled steel box with trim, Frame, door and accessories; J.L. Industries
<br />a. Mounting Semi -recessed
<br />b. Trim- Trimless
<br />c. Door and trim material- Enamelled steel, baked enamel finish
<br />d. Door Style- Duo -panel, bertical vinyl die cut letters
<br />SECTION 10800- TOILET AND BATH ACCESSORIES
<br />Scope: I. Provide toilet accessories at toilet rooms
<br />Products: I. Units: Stainless steel Fabrication with A151 No.4 bright directional polish finish;
<br />Bobrick Washroom Equipment, Inc.
<br />2. Mounting- Semi recessed and surface mounted
<br />3. Types and quantities:
<br />a. Waste dispenser
<br />b. Toilet tissue disperser
<br />c. Soap dispenser
<br />d. Grab bars; I set per toilet room
<br />e. Janitor's utility unit; 2 per closet
<br />f. Shower curtain rod; I per stall
<br />g. Shower Curtain and hooks; I per shower stall, mildew resistant
<br />h. Hinged shower seat
<br />I. Towel bars
<br />j. Mirror units, Stainless steel framed
<br />Lyndon T. Pollock
<br />Registered Architect AR0006747
<br />omwkj
<br />MARNWO
<br />U
<br />F--�1
<br />U
<br />0
<br />44
<br />U
<br />bill
<br />0
<br />o
<br />N
<br />00
<br />0
<br />U o M
<br />OZ
<br />rn r=, ON
<br />t3�M�DN
<br />F-�•I oNo w ism, �
<br />0
<br />x
<br />a
<br />� N v
<br />a,
<br />A
<br />r--4
<br />T- 4
<br />N
<br />Cd
<br />- --b
<br />V]
<br />O
<br />C�
<br />O
<br />U
<br />Cd
<br />4�
<br />Cis
<br />O �
<br />C�
<br />U =4
<br />U •a
<br />Project No. 09005.00
<br />IA5.21
<br />61612012 1:23:16 PM ...\cd\A5.2 Speclflcotlons.dgn
<br />D 2012 BH/PK Architects, Inc.
<br />
|