Laserfiche WebLink
N <br />s <br />0 <br />0 <br />v- <br />v- <br />00 <br />N1 o <br />o <br />N <br />C* <br />c2 <br />EF <br />DIVISION I - GENERAL <br />SECTION 01045 - GUTTING AND PATCHING <br />Scope: I. Cutting and patching includes cutting into existing construction For the installation <br />or performance of other work and patching required to restore the surfaces to their <br />original condition, <br />a. Unless otherwise specified the requirements for this section also apply to <br />mechanical and electrical work. <br />b. Do not cut and patch exposed work in a manner that in the architect/Engineers <br />opinion results in lessening the buildings aesthetic qualities. Replace any work <br />judged by the Architect/Engineer to be usually satisfactory. <br />SECTION 01500 - SUBMITTALS, PRODUCTS, AND SUBSTITUTIONS <br />Scope: I. Format for submittals: as required for specific type and by individual sections. <br />2. Types of submittals and number of copies. <br />o.5hop drawings, reviewed and annotated by the general contractor 6 copies <br />b. Product data - 6 copies <br />c. Samples - 2, plus extra samples as required to indicate range of color, Finish, and <br />texture to be expected. <br />d. Mock-ups - as required in individual sections. <br />e. Inspection and test reports - 4 copies <br />F. Warranties - 2 copies <br />g. Survey data - 2 copies. <br />In. Closeout submittals - 2 copies <br />DIVISION 6 - WOOD AND PLASTICS <br />SECTION 06100 - ROUGH CARPENTRY <br />Scope: I. Provide rough carpentry work <br />a. Noilers, blocking, Furring and sleepers <br />Products:l. Lumber, finished 4 sides, Icl% maximum moisture content. <br />a. Light framing: Construction grade Douglas fir or southern pine, appearance <br />grade where exposed. <br />b. Structural Framing and timbers: No. I grade Douglas fir or southern pine, <br />appearance grade where exposed. <br />c. Boards: Construction grade <br />2. Wood for nailers, Furring and sleepers: Construction grade, finished 4 sides, <br />IcI% moisture content. Pressure preservative treat items in contact with <br />roofing, flashing, waterproofing, masonry, concrete or the ground. <br />3. Plywood, APA rated for use and exposure. <br />a. Backing: Interior A/C grade. <br />4. Building paper: Asphalt saturated felt, non -perforated, ASTM D 226, Typ I. 30 Ibs <br />5. Wood treatment: <br />a. Exterior wood AWPA standard UI and TI. Cotogories UCI, UO2, UO3A, <br />U0313, CU4A, CU4B Alkaline Copper Quaternary based treatment. <br />b. Interior wood AWPA CI Timber, AWPA Cq Plywood, AWPA 031 Lumber not <br />in contact with ground and protected From water, AWPA 5 Waterborne <br />Preservatives, AWPA M4 Disodium Octoborote based treatment. <br />6. Sealants: For settings wood bucks and nailers in exterior openings. <br />1. Fire Retardant Treated Wood: All wood blocking within the insulated building <br />envelope shall be Fire retardant treated to comply with AWPA C20 (lumber} and <br />AWPA C21 (plywood) for treatment type. <br />a. Provide UL label on each treated. Redry treated lumber. <br />SECTION 06200 FIN15H CARPENTRY <br />Description of Work: <br />Wood trim, chair rail, crown molding and door casings as indicated on drawings <br />Quality Assurance <br />A. Factory -mark each piece of lumber and plywood with type, grade, mill and grading <br />agency identification. <br />B. Comply with applicable standards of AWI Architectural Woodwork Institute <br />secion 0300 <br />I. Grade Premium <br />Materials <br />A. Nominal sizes are indicated except as shown by detail dimensions. <br />Provide dressed or worked and dressed lumber, as applicable, <br />manufactured to actual sizes and patterns as shown. <br />B. Popular painted finish. Use pieces which are made of solid lumber stock. <br />C. Fasteners and Anchorages. Provide nails screws adn other anchoring <br />devices of the type size material and Finish required. For application <br />indicated to providesecure attachment concealed where possible. <br />Adjustment, Cleaning, Finishing and Protection <br />A. Repair damaged and defective finish carpentry work Kherever possible to eliminate <br />defects Functionally and visually; where not possible to repair properly, replace <br />woodwork. Adjust joinery for uniform appearance <br />SECTION 06400 - ARCHITECTURAL WOODWORK <br />Scope: I. Provide shop fabricated woodwork and casework. <br />Products:l. Quality standard For fabrication and products: Architectural Woodwork Institute <br />Quality Standards, Custom grade Flush overlay unless otherwise noted. <br />2. Wood species <br />a. Provide sealed plywood at sinks and wet areas. <br />3. Plastic laminate: all exposed and semi -exposed surfaces <br />AWI 5wction 400 premium grade <br />a. Horizontal surfaces: GP-50 (0.050" nominal thickness) <br />b. Vertical surfaces: GP-28 (0.28" nominal thickness) <br />SECTION 06400 - ARCHITECTURAL WOODWORK (cont) <br />4.5olid Surface- Provide solid surface counter tops extent as <br />shown on the drawings <br />5. Hardware: <br />Doors: <br />I pr hinges - Blum Clip 110 degree self closing <br />I pull Stanley 348515 5" Satin Chrome <br />Drawers: <br />I pull- Stanley 346515 5" Satin Chrome <br />I pr drawer slides Knape and Bogt No 1320 self closing <br />DIV15ION 1 - INSULATION <br />SECTION 01200 - INSULATION <br />Description of Work: <br />A. Extent of insulaiton work is shown on drawings and indicated by <br />provision of this seciton. <br />B. Appplications of insulaiton specified in this secion include the Following <br />1. Unfoced Fiberglass sound attenuation butts <br />2. Fire 5afing Insulation <br />Quality Assurance <br />A. Fire Performance Choracteristices <br />I. Surface Burning Characteristics A5TM E 84 <br />2. Fire Resistance Rating A5TM E Ilq <br />Acceptable Manufacturers <br />A. Manufacturers subject to compliance with requirements provide <br />products of one of hle following <br />I. Manufacturer of Fire 5aFing <br />IIG Minwool Corp. <br />Johns- Manville Corp. <br />United States Gypsum Co. <br />2. Manufacturer of Glass Fiber Insulaiton <br />CertainTeen Corp. <br />Knouf Fiber Glass Gmb H <br />Manvill Corp <br />Owens-Corning Fiberglas Corp. <br />Insulating Materials <br />A. General: Provide insulating materials which comply with <br />requirements indicated for materials compliance with reference <br />standards and other characteristics. <br />I. Preformed units sizes to fit application indicated, selected from <br />manufacturer's standard thickness, widths and lengths. <br />2. Sound attenuation butts. Provide unFoced mineral Fiber butt <br />insulation produced by combining9 gglass fibers with thermosetting <br />resins to comply with A5TM C 6b5 for Type I (blankets/butts without <br />membrane facing). Coordinate installation of sound attenuation <br />butts with installation of gypsum board. <br />3. Where sound -rated drywall construction is indicated seal construction <br />at perimeters, control and expansion joints, openings and penetrations <br />with a continuous bead of acoustical sealant including a bead at both <br />faces of partitions. Comply with ASTM C qlq and manufacturer's <br />recommendations for location of edge trim and close off sound -Flanking <br />paths around or through construction <br />B. Fire 5afing Provide fire sofing for installation in locations as indicated <br />or required. <br />I. Manufacturer shall provide certification that insulation complies with <br />OF plicable buildingg code requirements for performance of insulation <br />within fire protecEion assembly indicated on drawings IIG Minwool or eq. <br />DIVISION 8 - DOORS AND WINOOW5 <br />SECTION 08110 - WOOD DOOR d FRAME5 <br />Scope: I. Provide wood Frames <br />2. Provide solid core wood doors. <br />Products: I. Frames: Wood Frames to match existing: <br />2. Doors: 13/4" thick, Flush <br />Doors: 13/4" thick, 6 panel - Alternate #1 <br />a. Interior doors: Solid core Poplar <br />3. Finish <br />a. Painted <br />4. Fire Rating: UL Labeled where required. <br />Alternate #1 - Provide 6 panel wood door. Solis core wood <br />SECTION 06110 - FIN15H HARDWARE <br />Scope: I. Provide Finish hardware for sliding, swinging and bi-fold doors. <br />Products: I. ADA compatible hardware, Finish and type to match existing. <br />2. Hinges, butts and pivots: Full -mortise, 5knuckles <br />ball -bearing type: Stanley <br />3. Locksets and lotchsets: <br />a. Standard duty (light commercial): 5chloge <br />A Series. Lever style <br />4. Bolts adn coordinators: Ives <br />5. Exit devices: Von Duprin <br />6. Closers <br />a. Low Frequency doors: LCN 4050/4150 series. <br />b. High frenquency door (fire -labeled doors, toilet room doors, <br />stair doors) LON 4010/4110 series. <br />1. Door Trim: Kickplates, omor plate, plastic plates; Bobrick. <br />8. Stops: Ives <br />q. Thresholds:Pemco <br />10. Finish: Brushed Stainless <br />SECTION 05800 - GLASS AND GLAZING <br />Scope: I. Provide glass and glazing For all applications, including without <br />limitation, sidelights, interior glazed partitions walls, windows <br />and mirrors. <br />2. Glass Schedule: <br />a. Clear Float glass <br />b. %4" clear tempered as required by code <br />Products: I. Glazing Sheets <br />a. Heat treated glass products, Fed. Spec 00-6-1403 <br />I. Tempered glass <br />b. Mirrors, silvering copper coating, protective organic coating <br />DIVISION q - FIN15HES <br />SECTION Og250 - GYPSUM DRYWALL <br />Scope: I. Gypsum drywall including screw type metal support systems. <br />2. Drywall Finishing. Smooth joint tape and <br />compound treatment for paint finish <br />3. Moisture resistant gypsum board for installation in wet areas <br />such as toilet rooms, mop rooms, janitors closets, food service <br />areas, behind Fiberglass showers, and <br />under the balance of wall the installations. <br />Do not install in showers. <br />4.Type C fire code gypsum drywall For rated assemblies <br />Products: I. Gypsum wallboard: ASTM C 36, of types, edge configuration and thickness indicated: <br />in maximum lengths available to minimize end -to -end butt joints <br />a. Type: Regular, unless otherwise indicated. Type "X" for rated assemblies <br />which has been tested adn listed by recognized authorities including ULFN <br />and Gypsum Association <br />b. Edges: Tapered <br />c. Thickness: As indicated, or if not otherwise indicated, as required to comply <br />with A5TM 6840 For application system and supporting spacing indicated. <br />2. Wall/Partition Support Materials: <br />a. Studs: A5TM 0645: 20 gage unless otherwise indicated. Use 16 gage steel studs <br />at shower seat supports and rolling counter service doors or where required by equipment <br />b. Use minimum 20 gage studs at high walls and door/borrowed light jambs. <br />Consult manufacturers literature limiting height/gages of all wall assemblies <br />3. Accessories: Galvanized steel corner beads, casing beads, control joints <br />4. Acoustical sealant: US Gypsum Acoustical Sealant <br />SECTION 041300- TILE <br />Decription of work: <br />A. Porcelain wall tile, Floor base and trim <br />Quality Assurance: <br />A. AN51 Standard for Ceramic Tile: Comply with AN51 A131.1 "American <br />National Standard Specifications forCeromic Tile". Furnish the complying <br />with Standard Grade requirements unless otherwise noted. <br />B. Installation guidelines: Comply with the recommendatioins of the Tile Council of <br />America 2006 edition For installation procedures. <br />C. Propietory Materials: Handle, store, mix and apply proprietary <br />setting and grouting materials in compliance with manufacturer's instructions. <br />Samples: <br />A. Submit samples of each product specified <br />Extra Materials: <br />A. Deliver extra materials to owner. Furnish 3% extra materols that match product installed as described <br />below, package with protective covering for storage adn identiFed with lobles clearly describing contents. <br />Tile Products: <br />A. As specified on sheet A6.0 and A6.1 <br />Morter and Grout: <br />A. Latex modified portlond cement dry -set morter; AN51 A118.4 <br />Grout: <br />A. As Specified on Sheets Ab.0 and A6.1 <br />Tile Installation Standards: <br />A: Comply with ANSI Standards, AN51 A108.5, ANSI A108.6, <br />B. Manufacturer's requirements <br />C. Tile Council of America Guidelines <br />Tile installation: <br />A. Extend tile into recess and under or behind equipment and fixtures <br />B. Accurately Form intersections and returns. Carefully grid cut edges adn Fit the <br />closely to electrical outlets, piping and fixtures <br />C. Unless otherwise noted lay the in grid patter. Align joints when adjoining tiles on floor <br />base and walls and trim. Adjust to minimize the cutting. Provide uniform joint widths u.o.n. <br />SECTION 001510 - ACOUSTICAL CEILIN65 <br />Scope. I. Provide acoustical ceilings and metal suspension system. <br />2. Fire Performance Characteristics: Provide materials that are identical to those tested for <br />the following fire performance characteristics, per ASTM test method indicated below, <br />by UL or other testing and inspecting organizations acceptable to authorities having <br />jurisdiction. Identify acoustical ceiling components with appropriate markings of <br />applicable testing and inspecting organizations. <br />a. Flame spread 25 or less <br />b. Smoke developed 450 or less <br />3. Install products per manufacturers recommendations. <br />Products: I. Acoustical panels. To be Armstrong Cirrus 2 x 2 with angled tegulor edge <br />Exent as indicated on drawings <br />2. Exposed grid suspension system: To match existing. <br />3. Extra materials <br />a. Provide additional panels and grid in on amount equal to 2.0 percent of each type <br />of specified for maintenance stock. <br />SECTION 001650 - RESILIENT FLOORING <br />Scope: I. Provide resilient Flooring and base as indicated on drawings <br />2. Install per manufacturers recommendations <br />3. Fire Test Performance: Provide resilient Flooring which complies with the Following <br />fire test performance criteria as determined by an independent testing laboratory <br />acceptable to authorities having jurisdiction. <br />a. Critical Radiant Flux (CRF): Not less than the Following rating per ASTM E 648. <br />0.45 watts per so, cm. <br />b. Flame Spread: Not more than 25 per A5TM E 54. <br />c. Smoke Developed: Not more than 450 per A5TM E 84 <br />d. Smoke Density: Not more than 450 per ASTM Eb62 <br />e. Vinyl Plank extent as indicated on drawings <br />Products: 2. Accessories <br />a. Wall base: 4" vinyl cove as indicated on plans <br />Alternate #2 Provide decorative scupltured vinyl base <br />3. Adhesives (Cements): Waterproof, stabilized type as recommended by Flooring <br />manufacturer to suit material and substrate conditions. <br />4. Concrete slab primer. Non -staining type compatible with adhesive as recommended by <br />Flooring manufacturer. <br />5. Leveling compound: Latex type compatible with adhesive as recommended by <br />Flooring manufacturer. <br />6. Extra materials: <br />a. Provide additional resilient flooring in the amount of 2.0 percent for each type <br />specified For maintenance stock. <br />Guarantees and Warrantees <br />I. Upon completion the resilent Flooring contractor must submit a certificate <br />guaranteeing the, installation to be freee of defects in workmanship for a <br />period of I year to include the statement: that the resilent Flooring contractor <br />shall at his own expense and upon written notice from the Architect promply <br />correct/replace any and all improper work and material that may become <br />apparent within 12 months after the date of Final completion. <br />SECTION 001680 CARPETING <br />Summary <br />A. Extent location and details of each type of carpeting in indicated <br />on the drawings and room finish schedule <br />B. Work of this section includes furnishing and insulaiton of carpeting adhesives and <br />accessories including: <br />I. Broadloom carpet for glue -down installation with moisture barrier back <br />Quality Assurance <br />A. Carpet other than that specified on the drawings must be approved by <br />the Architect 10 days prior to bid date. <br />B. Provide fire test performance. Provide Class I carpeting which complies with <br />the Following fire test perfiormonce criteriai as determined by an independent <br />testing laboratory acceptable to authorities having jurisdiction. <br />I. Critical Radiant Flux (CRF) not less than the following rating per ASTM 648 <br />0.45 watts per sq.cm. <br />2. Flame Spread Not more than 25 per ASTM E 84 <br />3. Smoke Development Not more than 450 per A5TM E84 <br />4. Smoke Density Not more than 450 per A5TM E 662 <br />Site Visit <br />A. Contractor must visit the site and be responsible for ail measurements <br />and job conditions <br />Guarantees and Warrantees <br />I. Upon completion the carpeting contractor must submit a certificate <br />guaranteeing the installation to be freee of defects in workmanship For a <br />period of I year to include the statement: that the carpeting contractor <br />shall at his own expense and upon written notice from the Architect promply <br />correct/replace any and all improper work and material that may become <br />apparent within 12 months after the date of Final completion. <br />Maintenance Stock <br />A. Supply loose stock equal to 10% of each potern and type specified <br />Products <br />A. As indicated on plans <br />Installaiton <br />A. Comply with manufacturer's recommendations For seam locations and directions <br />of carpet monintoin uniformity of carpet directions and lay of pile at doors center seams <br />and under doors. Do not place seams in traffic direction at doorway. All seams <br />must be kept to a minimum and invisible as possible <br />B. Existing or previously treated substrate with respect to wax, soap or other residual <br />build-up must be removed prior to installation. <br />SECTION 0414100 PAINTING <br />Scope: I. Provide painting and surface preparation for all interior and exterior <br />surfaces, as required <br />2. Prepare surface and apply per manufacturers recommendation. <br />Products: I. Premium products for all systems <br />2. Interior Paint Schedule: New Surfaces: <br />a. Zinc -coated Metal <br />I. Semi -Gloss Alkyd Enamel: 2 finish coats over primer <br />b. Primed Metal <br />1. 5emi-Gloss Alkyd Enamel.. Two coats over existing primer <br />c. Gypsum Board Level 5 finish <br />I. Satin Latex Finishes: Two coats over primer <br />d. Existing Zinc Coated or Primed Metal: <br />1. Semi Gloss Alkyd Enamel: (2) coats over prepared surface. <br />SECTION 10440- SPECIALTY SIGNS <br />I. Provide specialty building signage <br />2. Provide signage in compiance with ADA requirements <br />SECTION 10522-FIRE EXTEING1,1I5HER5, CABINETS AND ACCESSORIES <br />Scope: 1. Provide portable fire extinguisher cabinets. Provide mounting brackets where no cabinet is indicated <br />Products: I. Fire Extinguishers: UL listed and labeled units J.L Industries <br />a. Multi -purpose dry chemical type. <br />2. Cabinets: Enamelled steel box with trim, Frame, door and accessories; J.L. Industries <br />a. Mounting Semi -recessed <br />b. Trim- Trimless <br />c. Door and trim material- Enamelled steel, baked enamel finish <br />d. Door Style- Duo -panel, bertical vinyl die cut letters <br />SECTION 10800- TOILET AND BATH ACCESSORIES <br />Scope: I. Provide toilet accessories at toilet rooms <br />Products: I. Units: Stainless steel Fabrication with A151 No.4 bright directional polish finish; <br />Bobrick Washroom Equipment, Inc. <br />2. Mounting- Semi recessed and surface mounted <br />3. Types and quantities: <br />a. Waste dispenser <br />b. Toilet tissue disperser <br />c. Soap dispenser <br />d. Grab bars; I set per toilet room <br />e. Janitor's utility unit; 2 per closet <br />f. Shower curtain rod; I per stall <br />g. Shower Curtain and hooks; I per shower stall, mildew resistant <br />h. Hinged shower seat <br />I. Towel bars <br />j. Mirror units, Stainless steel framed <br />Lyndon T. Pollock <br />Registered Architect AR0006747 <br />omwkj <br />MARNWO <br />U <br />F--�1 <br />U <br />0 <br />44 <br />U <br />bill <br />0 <br />o <br />N <br />00 <br />0 <br />U o M <br />OZ <br />rn r=, ON <br />t3�M�DN <br />F-�•I oNo w ism, � <br />0 <br />x <br />a <br />� N v <br />a, <br />A <br />r--4 <br />T- 4 <br />N <br />Cd <br />- --b <br />V] <br />O <br />C� <br />O <br />U <br />Cd <br />4� <br />Cis <br />O � <br />C� <br />U =4 <br />U •a <br />Project No. 09005.00 <br />IA5.21 <br />61612012 1:23:16 PM ...\cd\A5.2 Speclflcotlons.dgn <br />D 2012 BH/PK Architects, Inc. <br />