My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (119)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (119)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:25:36 PM
Creation date
2/25/2025 9:47:21 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Rodda Construction
Building Plans - Permit #
13245
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIRE PROTECTION NOTES <br />0 pl, <br />"wila <br />N <br />M O <br />a <br />N <br />Go <br />9 <br />Go <br />1. THIS BUILDING SHALL BE PROTECTED THROUGHOUT BY AUTOMATIC <br />SPRINKLERS. THE DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE <br />WITH NFPA 13, LATEST ENFORCEABLE EDITION. <br />2. ADHERE TO AND OBTAIN ALL PERMITS, LICENSES AND ALL GOVERNMENT <br />REQUIREMENTS. <br />3. ALL AREAS SHALL BE FIRE SPRINKLERED. THIS SHALL INCLUDE ELEVATOR <br />EQUIPMENT ROOMS, ELEVATOR SHAFT PIT, ELECTRICAL ROOMS, <br />TELEPHONE ROOMS, AND ANY CONCEALED SPACES OF COMBUSTIBLE <br />CONSTRUCTION. <br />4. REFER TO ARCHITECTURAL REFLECTED CEILING AND ELECTRICAL LIGHTING <br />DRAWINGS FOR CEILING DESCRIPTIONS AND HEIGHTS. <br />5. THE LOCATIONS OF SIAMESE CONNECTION, RISERS, FEED MAINS, CROSS <br />MAINS AND BRANCH PIPING WHERE SHOWN ON THE DRAWINGS IS APPROXIMATE. <br />FINAL LOCATION IS THE CONTRACTOR'S RESPONSIBILITY AND SHALL BE IN <br />COMPLIANCE WITH THE SPECIFICATIONS AND ALL APPLICABLE CODES OR <br />REGULATIONS. <br />6. PROVIDE HEADS GUARDS FOR SPRINKLERS IN ELECTRICAL ROOMS, ELEVATOR <br />MACHINE ROOMS AND ANY HEADS THAT ARE SUBJECT TO MECHANICAL DAMAGE <br />AND/OR BELOW T-0" <br />7. NOT ALL PIPING, VALVES AND APPURTENANCES ARE SHOWN ON PLANS. <br />REFER TO PIPING AND RISER DIAGRAMS, DETAILS AND SPECIFICATIONS <br />FOR ADDITIONAL INFORMATION. <br />8. INSPECTOR'S TEST CONNECTIONS SHALL BE PROVIDED FOR ALL ZONES SO <br />THAT THE WATER FLOW SWITCH FOR EACH ZONE CAN BE TESTED. <br />CONNECTIONS SHALL HAVE A MINIMUM 1 1/2 INCH OUTLET AND DRAIN <br />VALVE LOCATED IN AN ACCESSIBLE LOCATION PIPED TO AN APPROVED <br />LOCATION. <br />9. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON- ACCESSIBLE CEILINGS <br />AND CHASES. <br />10. ALL VALVES ON THE FIRE PROTECTION SYSTEM TO BE ELECTRICALLY <br />SUPERVISED. TYPE AND EXACT LOCATION OF FLOW AND SUPERVISORY <br />SWITCHES SHALL BE ACCOMPLISHED BETWEEN THE DIFFERENT RESPONSIBLE <br />TRADES. <br />11. PROVIDE A PERMANENTLY ATTACHED NAME TAG STATING THE REQUIRED <br />DESIGN CRITERIA FOR EACH HYDRAULICALLY DESIGNED SYSTEM. <br />12. ALL SPRINKLER HEADS MOUNTED IN CEILING SHALL BE LOCATED A MINIMUM <br />OF 4" AWAY FROM ANY WALLS, CEILING HEIGHT CHANGES OR ANY OTHER <br />VERTICAL INTERSECTING STRUCTURAL SURFACE. <br />13. PROVIDE SPRINKLERS ABOVE AND BELOW EXPOSED DUCTWORK 48" OR <br />WIDER. <br />14. PROVIDE ADDITIONAL OFFSETS OR FITTINGS REQUIRED FOR PROPER <br />INSTALLATION, COORDINATION WITH OTHER TRADES, AND/OR TO MAINTAIN <br />PROPER CLEARANCES. VERIFY STRUCTURAL, MECHANICAL, ELECTRICAL <br />INSTALLATIONS TO AVOID OBSTRUCTIONS OR INTERFERENCE WITH FIRE <br />PROTECTION PIPE ROUTING. <br />15. FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE WALLS. FIRESTOPPING SHALL <br />BE OF A U.L. LISTED ASSEMBLY. <br />16. SPRINKLER HEADS ARE TO BE COORDINATED WITH ALL DIFFUSERS, <br />SPEAKERS, LIGHTING FIXTURES, CEILING SYSTEMS AND STRUCTURAL <br />SYSTEM. <br />17. SPRINKLER SHOP DRAWINGS SHALL BE SUBMITTED TO ARCHITECT. NO <br />INSTALLATION SHALL BE PERMITTED UNTIL SPRINKLER SHOP DRAWINGS HAVE <br />BEEN APPROVED. <br />18. DESIGN CRITERIA: <br />A. ALL LIGHT HAZARD AREAS (OFFICES, TREATMENT ROOMS, ETC.) <br />SHALL BE HYDRAULICALLY DESIGNED FOR A DENSITY OF <br />0.10 GPM/SQ. FT. OVER THE MOST HYDRAULICALLY REMOTE 1,500 SQ. <br />FT. AND SHOULD INCLUDE A 100 GPM INSIDE HOSE STREAM ALLOWANCE. <br />B. ALL ORDINARY HAZARD AREAS (MECHANICAL ROOMS, STORAGE AREAS, <br />ETC.) SHALL BE HYDRAULICALLY DESIGNED FOR A DENSITY OF 0.20 <br />GPM/SQ. FT. OVER THE MOST HYDRAULICALLY REMOTE 1,500 SQ. FT. <br />AND SHOULD INCLUDE A 100 GPM INSIDE HOSE STREAM ALLOWANCE AND <br />A 150 GPM OUTSIDE HOSE STREAM ALLOWANCE. <br />20. UNLESS OTHERWISE NOTED, ALL SPRINKLER HEADS TO BE QUICK RESPONSE. <br />LEGEND <br />V 0 05 V <br />ZZo.1,017A <br />EXISTING PIPE <br />NEW PIPE <br />PIPING TO BE <br />REMOVED <br />NEW TO EXISTING <br />LIMIT OF REMOVAL <br />SPRINKLER BRANCH LINE OUTLET <br />(SPRINKLER OUTLET SHALL BE TO <br />THE SIDE, NOT DOWN.) <br />O <br />TEE CLAMP, CENTER ON TILES AS INDICATED <br />ON ARCH_ REFLECTED CEILING PLAN <br />CEILING TILE <br />CEILING GRID TEE <br />FLEXIBLE PIPE <br />PIPE CLAMP <br />TYPICAL SPRINKLER HEAD <br />FLEXIBLE PIPE OPTION <br />w <br />J <br />a <br />a <br />Y Z <br />U c <br />m= <br />C0 <br />1" CAST IRON <br />SCR. 90 DEG. ELL <br />1" CAST IRON SCR. 90 DEG. <br />ELL OR TEE (AS REQ'D) <br />SPRINKLER BRANCH LINE PIPING <br />(SPRINKLER OUTLET MAY BE TURNED <br />DOWN, DEPENDING ON SITUATION.) <br />1" PIPING TO PENDENT SPRINKLER HEAD <br />LINE OF SUSPENDED CEILING <br />u <br />TYPICAL SPRINKLER HEAD ------ Z <br />HARD PIPE OPTION <br />SUPPLY DETAIL FOR SPRINKLER HEADS <br />NTS <br />SPRINKLER SYMBOL DESCRIPTION <br />SYMBOL <br />SIZE <br />TYPE <br />RESP <br />FINISH <br />TEMP <br />K-FACTOR <br />EXISTING <br />--_ <br />r <br />__ <br />__ <br />o <br />CONCEALED <br />QR <br />WHITE <br />165 <br />5.6 <br />0 <br />y <br />SSU <br />QR <br />BRASS <br />165 <br />5.6 <br />O INDICATES SPRINKLER HEAD WITH GUARD <br />DRAWING INDEX <br />SHEET <br />NUMBER TITLE <br />FF.1 FIRE PROTECTION LEGEND, NOTES & SCHEDULES <br />FDA FIRE PROTECTION DEMOLITION PLAN - GROUND FLOOR <br />FKA FIRE PROTECTION PLAN - GROUND FLOOR <br />DEMOLITION NOTES <br />1. THE CONTRACTOR SHALL REMOVE ALL SPRINKLER HEADS, <br />PIPING, VALVES, EQUIPMENT, ETC. THAT IS OBSOLETE DUE <br />TO CHANGES IN THE BUILDING. <br />2. WHERE EXISTING CONDITIONS ARE SHOWN, THEY HAVE BEEN <br />DERIVED FROM AVAILABLE DRAWINGS AND REPRESENT THE <br />ENGINEER'S BEST ESTIMATE OF ACTUAL CONDITIONS BUT HAVE <br />NOT IN ALL CASES BEEN VERIFIED BY FIELD INVESTIGATION. <br />3. THE CONTRACTOR SHALL NOT ASSUME THAT EXISTING CONDITIONS <br />SHOWN ON THE DRAWINGS ARE COMPLETE AND ACCURATE <br />REPRESENTATIONS OF THE EXISTING FIRE PROTECTION SYSTEMS. <br />THE CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME FAMILIAR <br />WITH THE SITE CONDITIONS BEFORE SUBMITTING A BID. ANY ADDITIONAL <br />WORK CAUSED DUE TO LACK OF KNOWLEDGE OF EXISTING SYSTEMS <br />SHALL BE DONE AT NO ADDITIONAL EXPENSE TO THE OWNER. IF <br />AGREEABLE TO THE OWNER, THE CONTRACTOR CAN ESTABLISH LINE <br />ITEM COSTS FOR POSSIBLE DEMOLITION ITEMSTHAT ARE UNABLE TO <br />BE IDENTIFIED WITH REASONABLE INVESTIGATION. <br />U <br />C <br />W <br />N <br />Q <br />CD <br />N <br />� q <br />o C' <br />N <br />U � <br />O LL <br />=-m <br />O cum ccm,I <br />o <br />cacc <br />CD <br />'� o <br />_LL o <br />N M Z <br />O � <br />Cn <br />o 0 <br />C\J 0 O 0 <br />co LL II .J <br />0 <br />.Q <br />Cr <br />a <br />m <br />� N � <br />tN i <br />N r- <br />0 <br />N 1 <br />0 <br />Cn <br />W >-, <br />J � <br />N <br />L Cz <br />U CL <br />Cn O <br />cV <br />U) _7_ <br />L O <br />O LL <br />Z <br />Z <br />L' <br />L U <br />z= <br />O a� <br />U �--' <br />L Cz <br />F <br />O o0 <br />O <br />W Q <br />cc E <br />LL W <br />Project No. 09005.00 <br />FFA <br />$DATE$ $TIME$ $FILEA$ <br />02012 BWPK Architects, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.