My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (119)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (119)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:25:36 PM
Creation date
2/25/2025 9:47:21 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Rodda Construction
Building Plans - Permit #
13245
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VASSAR <br />NAOMI <br />N <br />N <br />� o <br />r- <br />V- <br />N <br />O <br />V- <br />N <br />ig <br />0 <br />WH1 <br />Accgssory CO3 CO2 <br />Cart' - Breast <br />Biopsy <br />Table <br />�, -TIC <br />' 1 LEA-2,4 <br />A �-T f� 2-#8 & 1410 CB <br />IF i GRND., IN Y4"C. <br />--- C01 <br />Consul <br />SHUNT <br />---- -- -- I TRIP <br />1 LCA-7 <br />lu <br />fr <br />T�; iIf <br />1 LCA-8 <br />I <br />, O(L"I L 1 RF WV2 <br />--, <br />r •7 SHUNT 1LEA-6,8 <br />TRIP <br />�.J -- -'- ----------� - - _ 248 & 1410 <br />— -- F - - - I -- - GRND., IN %4"C. <br />WH1 <br />� 1 LEA-3,5 WV1 <br />NOTE #3 / <br />� -� <br />248 & 1-#10a j <br />GRND., IN Y, C. / FD2 --1 ,- <br />CB1 q 1 LCA-10 11 <br />FD1 C01 <br />i <br />WV 1 WV2 <br />WH1 <br />1 LCA-9 <br />SHUNT �\ -- <br />TRIP <br />1 <br />C01 FD2 <br />C61 N'a��l�✓i? '� SUB -ITV` <br />r NOTE #3 <br />m <br />I <br />FD1 I a <br />I <br />I� <br />ENLARGE ROOMS #130. 131. 133. 134 & 135 <br />SCALE: %" = V-0" <br />NOTES: <br />1. SEE VENDOR DRAWINGS ON SHEETS <br />2. "C131" DEVICES ARE FLUSH MOUNTED ENCLOSED CIRCUIT BREAKERS SIZES <br />AS FLLOWS: <br />ROOM 130 - 208 V./l0, 35 AMP BRKR. <br />ROOM 133 - 208 V./l0, 35 AMP BRLR. <br />ROOM 134 - 208 V./l0, 35 AMP BRKR. <br />SQUARE BREAKER # <br />3. PROVIDE Y4" FLEX CONDUIT FROM END OF "FD1" TO BACK OF GANTRY (C -ARM). <br />SPECIAL ELECTRICAL NOTES <br />NOTES: <br />ALL JUNCTION BOXES, CONDUIT, WALL & FLOOR DUCTS, DIVIDERS, SWITCHES, CIRCUIT BREAKERS, ETC., ARE TO <br />BE SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR. <br />CONDUIT AND DUCT RUNS SHALL HAVE SWEEP RADIUS BENDS. <br />CONDUIT AND DUCT ABOVE CEILING OR BELOW FINISHED FLOOR MUST BE INSTALLED AS NEAR TO CEILING OR <br />FLOOR AS POSSIBLE TO REDUCE RUN LENGTH. <br />GROUNDING <br />1. PROVIDE REDUNDANT GROUNDING OF ALL EQUIPMENT. <br />2. PROVIDE GROUND BUSHINGS OF ALL NIPPLES. <br />3. PROVIDE GROUND JUMPERS AT ALL DUCT JOINTS. <br />4. ALL HOLOGIC, INC. MEDICAL CABINETS MUST BE CONNECTED TO THE DUCT OR JUNTION BOXES WITH <br />DIRECT BONDING OR JUMPER WIRES. <br />5. PROVIDE GROUND WIRE FROM DUCT OR JUNCTION BOXES TO T.V. MONITOR OR X - RAY TUBE UNIT. <br />SEPARATIONS <br />1, ALL CABLES MUST BE SEPARATED BY VOLTAGE MARKED ON CABLES AND BY CLASS FROM OTHER <br />CABLES. <br />2. DUCT DIVIDERS MUST HAVE PROPER CROSS OVERS TO KEEP CLASS WIRING SEPARATED. <br />3. DIGTAIL WIRING, POWER, BUSS CABLES, COAXIAL CABLES MUST BE KEPT IN SEPARATE DUCT <br />COMPARTMENT FOR ENTIRE RUN. <br />4. TERMINATION POINTS OF MONITORS, ETC. REQUIRE SEPARATE JUNCTION BOXES AND COVERPLATES <br />FOR POWER AND VIDEO WITH BLANK COVERPLATES REQUIRED. INDIVIDUAL CONDUIT RUNS ARE <br />SUGGESTED WHEN POSSIBLE. <br />PROVIDE LISTING OF CABLE TYPES AND CLASS IN DUCTS AND CONDUIT FOR REVIEW AT FINAL INSPECTION. <br />COORDINATE ALL WORD ON THIS SHEET WITH HOLOGIC, INC. MEDICAL EQUIPMENT SUPPLIERS AND INSTALLERS. <br />Project No. 09005.00 <br />E4.2 <br />$DATE$ $TIME$ $FILEA$ <br />©2012 BHIPK Architects, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.