COMMUNICATIONS SYMBOLS <br />u <br />WOTIAr".41rd, <br />N <br />Nt <br />N <br />co <br />go <br />0 <br />COMMUNICATIONS SYSTEMS: <br />NOTE: NOT ALL SYMBOLS SHOWN MAY BE REQUIRED FOR THIS PROJECT. <br />NURSE CALL SYSTEMS: FIRE ALARM SYSTEMS: <br />CONDUIT & RACEWAYS: <br />OS MUSIC. FP FIREMAN'S PHONE RACEWAYEXPOSED CR'NN ICATES RACEWAY DUIT OR SURFACE GENERAL NOTES: <br />M SINGLE PATIENT NURSE CALL STATION, 1. THE EXISTING CONDITIONS ARE SHOWN AS ACCURATELY AS FIELD CONDITIONS <br />60" ABOVE FLOOR OR AS NOTED. FCP FIRE ALARM CONTROL PANEL WOULD PERMIT. BIDDERS SHALL THOROUGHLY EXAMINE THE CONTRACT DOCUMENTS, <br />OS SPEAKER OUTLET RECESSED IN CEILING (UNLESS CONDUIT CONCEALED IN WALL OR VISIT THE SITE &VERIFY ALL EXISTING CONDITIONS. THE CONTRACTOR SHALL <br />R NOTED OTHERWISE) - S INDICATES SURFACE FSA FIRE ALARM SYSTEM ANNUNCIATOR CEILING CONSTRUCTION REPORT TO THE ARCHITECT/ENGINEERING FIRM BEFORE SUBMITTING A BID, AN <br />TYPE - C INDICATES SPEAKER CONCEALED ABOVE DUAL PATIENT NURSE CALL STATION, FTR FIRE ALARM TRANSPONDER / TRANSMITTER I ' Y <br />CEILING -'P' INDICATES PROJ. HORN TYPE -'DF' 60" ABOVE FLOOR OR AS NOTED. , _ - - - _ , CONDUIT CONCEALED IN FLOOR CONDITIONS WHICH MIGHT MAKE INSTALLATION OF REQUIRED EQUIPMENT A PROBLEM. <br />INDICATES DOUBLE FACE TYPE. ESR ELEVATOR STATUS RECALL CONSTRUCTION OR UNDERGROUND NO CONSIDERATION OR ALLOWANCE WILL BE GRANTED FOR FAILURE TO INVESTIGATE <br />FAC FIRE ALARM COMMUNICATOR CONDITIONS OR MISUNDERSTANDINGS OF THE CONTRACTURAL REQUIREMENTS. <br />SPEAKER OUTLET RECESSED IN WALL (UNLESS EMERGENCY CALL STATION - �MT� SPECIAL SYSTEM WIRING TO CENTRAL 2. IT IS THE INTENT OF THESE DRAWINGS TO CALL FOR FINISHED WORK TESTED & <br />OTHERWISE NOTED) - MOUNTED +84" ABOVE FLOOR OR AS 'PB' INDICATES PUSH BUTTON (+42") HCP HALON CONTROL PANEL EQUIPMENT, PANEL, TERMINAL CABINET READY FOR OPERATION. THE WORD "PROVIDE" MEANS "FURNISHED & INSTALL <br />NOTED -'S' INDICATES SURFACE TYPE. 'PC' INDICATES PULL CORD. (+42") FM2 FM-200 PANEL OR NEXT DEVICE. COMPLETE & READY FOR USE". <br />TYPE -'P' INDICATES PROJECTION HORN TYPE -'DF' INDICATES DOUBLE FACE TYPE. 'FS' INDICATES FOOT SWITCH (FLOOR) HVA I HVAC / STAIR PRESSURIZATION CONTROL PANEL TD = TELEPHONE AND DATA 3. SEAL ALL FLOOR & FIRE -RATED WALL PENETRATIONS WITH UL APPROVED <br />F PULL STATION MOUNTED @ + 42" ABOVE FLOOR MT = EMPTY FIREPROOFING MATERIALS. <br />0 VOLUME CONTROL - NUMERAL DESIGNATES NURSE CALL DOME LIGHT - NUMERAL CP = MASTER CLOCK & PROGRAM SYSTEM 4. MOUNTING HEIGHT GIVEN ON ELECTRICAL DRAWINGS ARE FOR BIDDING PURPOSES <br />'Z' <br />I ASSOCIATED SPEAKERS. INDICATES TYPE - AFTER NUMERAL S SPEAKER - WALL MOUNTED + 80" ABOVE FLOOR MC = MASTER CLOCK SYSTEM <br />q @ IC INTERCOM SYSTEM ONLY. REFER TO ARCHITECTURAL ELEVATION DRAWINGS FOR MOUNTING HEIGHTS OF <br />INDICATES ZONE DOME LIGHT. <br />OM MICROPHONE OUTLET - IN FLOOR BOX re") TV - TELEVISION SYSTEM ALL WIRING DEVICES & EQUIPMENT JUNCTION BOXES. WHERE DISCREPANCIES OCCUR <br />M MICROPHONE OUTLET - IN WALL A SPEAKER - CEILING MOUNTED TVC -TELEVISION REMOTE CONTROL BETWEEN ELECTRICAL & ARCHITECTURAL DOCUMENTS, THE ARCHITECTURAL <br />I NURSE CALL DOME LIGHT WITH NC =NURSE CALL SYSTEM ELEVATIONS TAKE PRECEDENCE. <br />�, <br />CLOCK OUTLET IN CEILING WITH PROGRAM NORMAL CALL LAMP. HORN WITH LIGHT AS ONE ASSEMBLY - P =PAGING SYSTEM 5. FOR ACTUAL LOCATION OF RECESSED SPEAKERS AND SMOKE DETECTORS, SEE <br />OR OTHER SYSTEM CLOCK AS SPECIFIED- � WALL MOUNTED @ + 80" ABOVE FLOOR T -TELEPHONE SYSTEM ARCHITECTURAL REFLECTED CEILING PLANS. <br />'DF' INDICATES DOUBLE FACE CLOCK NURSE CALL DOME LIGHT WITH GF = CIRCUIT TO GROUND FAULT <br />DIMENSION INDICATES DIAL SIZE. TT <br />EMERGENCY CALL LAMP(S). � CHIME WITH LIGHT AS ONE ASSEMBLY - CIRCUIT BREAKER 6. EACH TELEPHONE OUTLET SHALL HAVE ONE DOUBLE GANG BOX WITH SINGLE GANG <br />o PLASTER RING AND ONE 3/4" CONDUIT TO NEAREST CORRIDOR CABLE TRAY SYSTEM. <br />CLOCK OUTLET IN WALL WITH PROGRAM XX WALL MOUNTED @ + 80" ABOVE FLOOR EIL = EQUIPMENT INTERLOCK SELECTED OUTLETS MUST BE LOCATED ABOVE OR IN CASEWORK RESPECTIVELY. <br />OR OTHER SYSTEM CLOCK AS SPECIFIED NURSE CALL DOME LIGHT WITH NORMAL yy <br />MP = MUSIC / PAGING SYSTEM CHECK ARCHITECTURAL ELEVATIONS, CASEWORK AND EQUIPMENT DRAWINGS. <br />'DF' INDICATES DOUBLE FACE CLOCK AND EMERGENCY CALL LAMPS. BELL WITH LIGHT AS ONE ASSEMBLY - CPP = CENTRAL PAGE / PROGRAM SYSTEM 7. EACH INFORMATION MANAGEMENT OUTLET IMO SHALL HAVE ONE DOUBLE GANG <br />DIMENSION INDICATES DIAL SIZE. WALL MOUNTED @ + 80" ABOVE FLOOR STV = SECURITY TELEVISION SYSTEM BOX WITH SINGLE GANG PLASTER RING & ONE 1" CONDUIT TO NEAREST CORRIDOR <br />MOUNTED +84" ABOVE FLOOR OR AS NOTED. M = MUSIC SYSTEM <br />NURSE CALL DOME LIGHT WITH NORMAL, CABLE TRAY SYSTEM. SELECTED OUTLETS MUST BE LOCATED ABOVE OR IN <br />COMBINATION CLOCK AND SPEAKER EMERGENCY AND CODE BLUE CALL LAMPS. o HORN WITH LIGHT AS ONE ASSEMBLY - DS CAMER SECURITY CASEWORK RESPECTIVELY. CHECK ARCHITECTURAL ELEVATIONS, CASEWORK & <br />OUTLETS IN COMMON BACK BOTH - WITH CEILING MOUNT _ _ _ EQUIPMENT DRAWINGS. <br />CLOCK AND SPEAKER AS SPECIFIED. NURSE CALL DOME LIGHT WITH CODE XX DIRECT BURIAL CABLE 8. COORDINATE THE LOCATION OF DUCT DETECTOR CONNECTIONS WITH MECHANICAL <br />MOUNTED +84" ABOVE FLOOR OR AS NOTED. BLUE CALL LAMPS. � STROBE - WALL MOUNTED @ + 80" ABOVE FLOOR HOME RUN TO PAN ELBOARD-N UMBER OF DRAWINGS AND CONTRACTOR. <br />PROGRAM OR SIGNAL BELL - MOUNTED +84" ABOVE ARROWS INDICATES NUMBER OF CIRCUITS <br />��t I FLOOR OR AS NOTED. VT NURSE CALL DOME LIGHT WITH CODE ;o� STROBE - CEILING MOUNT EXPLOSION BUZZER - MOUNTED +84" ABOVE FLOOR OR AS NOTED. BLUE AND EMERGENCY CALL LAMPS. - NO - SET 1 W CONDUIT EALS.OF CONDUIT WITH <br />XX SUBSCRIPT @ WATT <br />TELEVISION ANTENNA SYSTEM OUTLET, STAFF LOCATOR DOME LIGHT WITH 1/4 - SET @ 1/4 WATT <br />a-- WITH REMOTE CONTROL STATION, IN WALL FOUR COLOR CODED LAMPS. 1/2 - SET @ 1/2 WATT LAY IN WIREWAY DUCT, SIZE AS NOTED. <br />AT +84" ABOVE FLOOR OR AS NOTED. 2 - SET @ 2 WATT CABLE TRAY, SIZE AS NOTED. <br />TELEVISION ANTENNA SYSTEM OUTLET, NURSE CALL AUDIBLE ALARM SIGNAL. YY - NO SUBSCRIPT -15 CANDELA RATED <br />WITH REMOTE CONTROL STATION 30 - 30 CANDELA RATED FEEDER DUCT -RATING AND NUMBER <br />MOUNTED IN CEILING. NURSE CALL DUTY STATION - MOUNTED +54" ABOVE 60 - 60 CANDELA RATED OF CONDUCTORS AS NOTED. <br />TELEVISION ANTENNA SYSTEM OUTLET IN FLOOR OR AS NOTED. ('D' INDICATES DOUBLE.) 95 - 95 CANDELA RATED <br />WALL AT +18" ABOVE FLOOR OR AS NOTED. 110 -110 CANDELA RATED PLUG IN DUCT -RATING AND NUMBER <br />TELEVISION CAMERA OR VIDEO TAPE JACK. NURSE CALL STAFF STATION - MOUNTED +54" ABOVE SMOKE DETECTOR ( GENERIC) OF CONDUCTORS AS NOTED. <br />FLOOR OR AS NOTED. ('D' INDICATES DOUBLE.) O- SMOKE DETECTOR, SPECIFIC TYPES PLUG IN STRIP TYPE RECEPTACLES OR <br />CLOSED CIRCUIT TELEVISION OUTLET, ASD. AIR SAMPLER OTHER OUTLETS AS NOTED. <br />IN WALL AT +18" ABOVE FLOOR OR AS NOTED. NURSE CALL EQUIPMENT JACK - MOUNTED +54" ABOVE <br />FLOOR OR AS NOTED: BF. BELOW FLOOR <br />TELEVISION ANTENNA SYSTEM IN CEILING. BR. BEAM RECEIVER — — - E- — — UNDER FLOOR DUCT -ELECTRICAL <br />CLOSED CIRCUIT TELEVISION OUTLET, BT. BEAM TRANSMITTER UNDERFLOOR DUCT - TELEPHONE OR <br />Ce IN CEILING XS NURSE CALL TRANSFER SWITCH. I. IONIZATION PRODUCES OF COMBUSTION DETECTOR T <br />C INTERCOM MASTER -DESK MOUNTED. j <br />P. PHOTOELECTRIC PRODUCTS OF COMBUSTION DETECTOR OTHER LOW TENSION AS NOTED. <br />M ❑ SS NURSE CALL SWING SWITCH. SMOKE DETECTOR IN DUCT Q CONDUIT UP <br />M IC INTERCOM MASTER - WALL MOUNTED 60" 0. OUTSIDE AIR DUCT <br />ABOVE FLOOR OR AS NOTED. � CODE BLUE CALL STATION - R. RETURN AIR DUCT CONDUIT DOWN <br />I C INTERCOM REMOTE UNIT - DESK MOUNTED. 'PB' INDICATES PUSH BUTTON S. SUPPLY AIR DUCT PULL BOX <br />'FS'�INDICATES FOOT SWITCH <br />INTERCOM REMOTE UNIT - WALL MOUNTED +42 ABOVE OF FLOOR OR AS NOTE. HEAT DETECTOR (GENERIC) <br />GROUND <br />+60" ABOVE FLOOR OR AS NOTED. � HEAT DETECTOR, SPECIFIC TYPES <br />TELEPHONE OUTLET - IN WALL +18" ABOVE � NURSE CALL DUTY STATION (VISUAL SYSTEM). - 000a BUS DUCT <br />FLOOR AS NOTED. MOUNTED +54 ABOVE OF FLOOR OR AS NOTE. R/F. COMBINATION RATE OF RISE <br />AND FIXED TEMPERATURE POWER/COMMUNICATIONS LINEAR RACEWAY <br />TELEPHONE OUTLET - IN FLOOR BOX. AUDIO-VISUAL NURSE CALL SYSTEM R/C. RATE COMPENSATION _ _ _ - - - - - <br />AV E <br />INFORMATION MANAGEMENT (IMO) WALL MOUNTED CENTRAL EQUIPMENT WITH POWER SUPPLY. F. FIXED TEMPERATURE MAPNET CIRCUIT <br />+18 ABOVE FLOOR OR AS NOTED. 'R' INDICATES RECESSED IN FINISHED WALL. R. RATE OF RISE ONLY <br />INFORMATION MANAGEMENT OUTLET (IMO) 'TS' INDICATES TOUCH SCREEN Oj LINE -TYPE DETECTOR ( HEAT -SENSITIVE CABLE) ZI FLOOR DUCT <br />IN FLOOR BOX. VISUAL NURSE CALL SYSTEM CENTRAL EQUIPMENT © FIRE SERVICE OR EMERGENCY TELEPHONE STATION <br />UP <br />INFORMATION MANAGEMENT (IMO) WALL MOUNTED WITH POWER SUPPLY.'R' INDICATES RECESSED <br />+18" ABOVE FLOOR OR AS NOTED. WIRE ALL IN FINISHED WALL. TYPES OF FIRE SERVICE OR EMERGENCY TELEPHONE STATION <br />DEVICES WITH THIS SYMBOL. ©. A. ACCESSIBLE FIRE SERVICE OR EMERGENCY TELEPHONE STATION <br />PAY TELEPHONE OUTLET - IN WALL 48" ABOVE NC NURSE CALL CONSOLE -DESK MOUNTED. J. JACK FOR FIRE SERVICE OR EMERGENCY TELEPHONE STATION NOTES: <br />FLOOR OR AS NOTED. F AUTOMATIC DOOR RELEASE CONNECTION <br />P COMBINATION FLOOR BOX DOUBLE DUPLEX V N C VISUAL NURSE CALL ANNUNCIATOR. O 1. REFER TO PROJECT MANUAL AND/OR PROJECT <br />� � 'CB' INDICATES CODE BLUE. DRAWINGS FOR MOUNTING HEIGHTS. <br />P RECEPTACLE - 3W. IN WALL +54" ABOVE FLOOR OR AS NOTED. O MAGNETIC DOOR CONTACT. <br />IN <br />TO BE POURED IN PLACE. <br />2. UPPER CASE LETTERS'DD' AT DUPLEX <br />RECEPTACLE INDICATES DOUBLE DUPLEX <br />COMBINATION FLOOR BOX, DOUBLE DUPLEX A REMOTE POWER SUPPLY ALARM STATION FOR O CARD /KEY READER RECEPTACLE IN TWO GANG BOX. <br />R RECEPTACLE - 20A 125V 2P. 3W. AUDIONISUAL NURSE CALL SYSTEM. <br />TO BE USED IN RAISED FLOOR TILES. 0 SMOKE DAMPER CONNECTION 3. LETTERS'WP' AT DEVICE OR EQUIPMENT <br />CH <br />INDICATES NEMA 3R TYPE. <br />JUNCTION BOX IN WALL 48" ABOVE FLOOR STAFF LOCATOR STATION © FAN SHUT -DOWN CONNECTION. 4. LETTERS'EX' AT DEVICE INDICATES EXISTING. <br />OE TELEPHONE AND DATA EQUIPMENT CONNECTION NC NURSE CALL CONSOLE - RECESSED WALL SPRINKLER FLOW SWITCH 5. LETTERS "XP' AT DEVICE OR EQUIPMENT <br />FOR POWER POLE. IN CEILING SPACE <br />PP MOUNTED +54 ABOVE FLOOR OR AS NOTED. V INDICATES EXPLOSIONPROOF TYPE. <br />AMP AMPLIFIER VALVE WITH TAMPER PRESSURE SWITCH 6. UPPER CASE LETTER'W AT TELEPHONE <br />OUTLET INDICATES WALL MOUNT. <br />P 7. PLUS (+) SIGN WITH DIMENSION AT Heery I <br />VALVE WITH TAMPER SWITCH (SUPERVISORY) OUTLET INDICATES HEIGHT ABOVE 4700 M <br />SPRINKLER PRESSURE SWITCH (ALARM) FINISHED FLOOR LINE OR HEIGHT Suite F <br />ABOVE FINISHED GRADE TO CENTER. Orland <br />PS AIR PRESSURE SWITCH ( ALARM) Eg7.�0 <br />LPS LOW AIR PRESSURE SWITCH ( SUPERVISORY) Seal: <br />QR -{ DUCT SMOKE DETECTOR REMOTE TEST/RESET STATION. <br />R� REMOTE DETECTOR INDICATOR LIGHT <br />FIREMANS PHONE JACK +48" <br />F - <br />Project No. 09005.00 <br />COO 11 <br />$DATE$ $TIME$ $FILEA$ <br />© 2012 BH/PK Architects, Inc. <br />